New

LTS-3000A – Liquid Based Cytology Slide Processor

$0.00

Shipped From Abroad

The Lituo LTS-3000A is a high-throughput liquid-based cytology slide processor, designed to prepare uniformly distributed monolayer smears from various body fluids or exfoliative cytology specimens, improving consistency and workflow efficiency in cytology laboratories.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Lituo

Description

The instrument combines density-gradient centrifugation, natural sedimentation, and charge capture to complete the automation of specimen processing, transfer, sedimentation, and staining in an operation. Complete slide production and staining at one time without manual intervention.

Features

Convenient: 1–8 specimens can be processed, which makes specimen processing more convenient and timely.

Time-saving: The centrifugal & staining system can be operated individually. Batch processing time is less than 30 minutes.

Intelligent: Specimen process, transfer, sedimentation, and staining are done together, which realizes multifunctional, intelligent, microprocessor-controlled, and full automation.

Full automatic: The processor is upgraded from conventional manual operation to intelligent automation, which reduces labor and avoids mistakes.

Multifunctional: The following values can be set on demand: specimen type, specimen quantity, staining method, staining time, centrifugation time, and rate. The working modes are adjustable and can be realized during operation.

High Detection Ratio: The capture capability of lesion cells and the positive detection ratio are improved greatly by techniques like density-gradient centrifugation, natural sedimentation, and charge capture.

Pipeline anti-occlusion: The anti-occlusion & clearance techniques are adopted comprehensively in case of the staining needle occlusion.

Charge Capture: With a special slide silicified technique, the charge coat becomes stable and endurable without the need for gluing.

Slide Effect: The diagnostic material is available with a clear background and a thin, even layer of cells.

Application: Slide processing & staining of cell specimens prior to pathological analysis.

Technical Specifications
Specification Details
Model LTS-3000A
Method Liquid-based cytology slide processor (sedimentation)
Typical Throughput 8 specimens in ~30 minutes
Certifications CE, ISO13485
Application Cytology labs: body fluid & exfoliative specimen processing

Reviews

There are no reviews yet.

Be the first to review “LTS-3000A – Liquid Based Cytology Slide Processor”

Your email address will not be published. Required fields are marked *

Quick Comparison

LTS-3000A - Liquid Based Cytology Slide Processor removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
NameLTS-3000A - Liquid Based Cytology Slide Processor removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
ImageAvalun Labpad machineDrug Test Cup
SKUSF1033560084-65SF1033560084-23SF1033560060-2SF1033560084-129SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Lituo LTS-3000A is a high-throughput liquid-based cytology slide processor, designed to prepare uniformly distributed monolayer smears from various body fluids or exfoliative cytology specimens, improving consistency and workflow efficiency in cytology laboratories.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe instrument combines density-gradient centrifugation, natural sedimentation, and charge capture to complete the automation of specimen processing, transfer, sedimentation, and staining in an operation. Complete slide production and staining at one time without manual intervention.
Features
Convenient: 1–8 specimens can be processed, which makes specimen processing more convenient and timely. Time-saving: The centrifugal & staining system can be operated individually. Batch processing time is less than 30 minutes. Intelligent: Specimen process, transfer, sedimentation, and staining are done together, which realizes multifunctional, intelligent, microprocessor-controlled, and full automation. Full automatic: The processor is upgraded from conventional manual operation to intelligent automation, which reduces labor and avoids mistakes. Multifunctional: The following values can be set on demand: specimen type, specimen quantity, staining method, staining time, centrifugation time, and rate. The working modes are adjustable and can be realized during operation. High Detection Ratio: The capture capability of lesion cells and the positive detection ratio are improved greatly by techniques like density-gradient centrifugation, natural sedimentation, and charge capture. Pipeline anti-occlusion: The anti-occlusion & clearance techniques are adopted comprehensively in case of the staining needle occlusion. Charge Capture: With a special slide silicified technique, the charge coat becomes stable and endurable without the need for gluing. Slide Effect: The diagnostic material is available with a clear background and a thin, even layer of cells. Application: Slide processing & staining of cell specimens prior to pathological analysis.
Technical Specifications
Specification Details
Model LTS-3000A
Method Liquid-based cytology slide processor (sedimentation)
Typical Throughput 8 specimens in ~30 minutes
Certifications CE, ISO13485
Application Cytology labs: body fluid & exfoliative specimen processing
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare