Mainstream Multigas Module AneSure-M

$0.00

Shipped From Abroad

Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of Mainstream Multigas Module AneSure-M
  • Reliable multi gas OEM solution

Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Mainstream Mode

Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.

  • Automatic Pressure Compensation

There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure™-M
Working condition 5°C to 50°C, 10 to 90% RH, noncondensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol
EtCO2, FiCO2 measurement range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatically compensation if O2 equipped
Barometric Pressure Having barometric pressure sensor and automatically compensation
Warm-up time 10 seconds reach designed deviation 97%,

20 seconds reach designed deviation.

Rise times (t10- 90 %) CO2:<70ms

N2O and AGENT:<300ms

Calibration No need to calibrate
Zero Implement when replacing adaptor

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
  • Equipped with an Oxygen battery, reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream mode can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic pressure compensation. There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for the temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Mainstream Multigas Module AneSure-M”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMainstream Multigas Module AneSure-M removeDrip Stand removeHersill Genesis Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeKIT FOR THORACENTESIS & PARACENTESIS removeRender SD-M2000A Anesthetic Machine remove
NameMainstream Multigas Module AneSure-M removeDrip Stand removeHersill Genesis Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeKIT FOR THORACENTESIS & PARACENTESIS removeRender SD-M2000A Anesthetic Machine remove
ImageHersill Genesis Anaesthetic Machine
SKUSF1033560084-67SF1033560450-1SF1033560011-12SF1033560130101-5SF1033560011-13
Rating
Price

$0.00

$27.00

$0.00

$1,320.00

$0.00

$1,870.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Mainstream Multigas Module AneSure-M
  • Reliable multi gas OEM solution
Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream Mode
Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure™-M
Working condition 5°C to 50°C, 10 to 90% RH, noncondensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol
EtCO2, FiCO2 measurement range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatically compensation if O2 equipped
Barometric Pressure Having barometric pressure sensor and automatically compensation
Warm-up time 10 seconds reach designed deviation 97%, 20 seconds reach designed deviation.
Rise times (t10- 90 %) CO2:<70ms N2O and AGENT:<300ms
Calibration No need to calibrate
Zero Implement when replacing adaptor
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
  • Equipped with an Oxygen battery, reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream mode can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic pressure compensation. There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for the temperature range of - 5-50 °C and in the range of 0 - 20%.
Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Use : Bedridden patients, Senior citizen care, Patients in coma Advantages :
  • High quality stainless steel construction
  • Properly electroplated for anti rust finish
  • Ball shaped castors for smooth movement
  • Provided with an infusion stand
  • Attached 4 pcs hook
  • Maximum load strength
  • Screw safety height adjustment
  • Light weight
   
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 

KIT FOR THORACENTESIS & PARACENTESIS

The device is used to drain ascitic fluid and pleural liquid, it contains everything necessary for performing thoracentesis and paracentesis procedure (needles  syringe and collection bag). Products are customized upon request.  
Reference Description Qty per box
H92000E TORASET 1-55 30 pcs
H92010E TORASET 1-80 30 pcs
H92020E TORASET 1-VER 30 pcs
H92030E TORASET2-55 30 pcs
H92040E TORASET 2-80 30 pcs
H92050E TORASET 2-VER 30 pcs
H92001E TORAMATIC 1-55 30 pcs
H92011E TORAMATIC 1-80 30 pcs
H92021E TORAMATIC 1-VER 30 pcs
H92120E PARASET 2 30 pcs
H92160E PARASET 5 20 pcs
H92200E PARASET 8 20 pcs
H92240E PARASET 12 15 pcs
 
Click here to download Catalogue
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
 
Click Here To Download Catalogue
   
 