Mainstream Multigas Module AneSure-M

$0.00

Shipped From Abroad

Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-11
Brands:: Kingst

Description

Features of Mainstream Multigas Module AneSure-M
  • Reliable multi gas OEM solution

Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Mainstream Mode

Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.

  • Automatic Pressure Compensation

There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure™-M
Working condition 5°C to 50°C, 10 to 90% RH, noncondensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol
EtCO2, FiCO2 measurement range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatically compensation if O2 equipped
Barometric Pressure Having barometric pressure sensor and automatically compensation
Warm-up time 10 seconds reach designed deviation 97%,

20 seconds reach designed deviation.

Rise times (t10- 90 %) CO2:<70ms

N2O and AGENT:<300ms

Calibration No need to calibrate
Zero Implement when replacing adaptor

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
  • Equipped with an Oxygen battery, reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream mode can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic pressure compensation. There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for the temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Mainstream Multigas Module AneSure-M”

Your email address will not be published. Required fields are marked *

Quick Comparison

Mainstream Multigas Module AneSure-M removeLab/Ward Coat removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000B Anesthetic Machine removeBistos BT-770-12.1" Touchscreen Patient Monitor removeSiare Morpheus M Anaesthetic Machine remove
NameMainstream Multigas Module AneSure-M removeLab/Ward Coat removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000B Anesthetic Machine removeBistos BT-770-12.1" Touchscreen Patient Monitor removeSiare Morpheus M Anaesthetic Machine remove
ImageFingertip Pulse OximeterBistos BT-770-12.1" Touchscreen Patient Monitor
SKUSF1033560130170-11SF1033560084-222SF1033560084-2SF1033560011-10SF1033560059-1SF1033560101-2
Rating
Price

$0.00

$11.00

$17.00

$4,840.00

$902.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Mainstream Anesthesia Multi-Gas Module, simultaneously measures the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Mainstream Multigas Module AneSure-M
  • Reliable multi gas OEM solution
Equipped With Oxygen Battery. Reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream Mode
Can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure™-M
Working condition 5°C to 50°C, 10 to 90% RH, noncondensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol
EtCO2, FiCO2 measurement range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatically compensation if O2 equipped
Barometric Pressure Having barometric pressure sensor and automatically compensation
Warm-up time 10 seconds reach designed deviation 97%, 20 seconds reach designed deviation.
Rise times (t10- 90 %) CO2:<70ms N2O and AGENT:<300ms
Calibration No need to calibrate
Zero Implement when replacing adaptor
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-M
  • Equipped with an Oxygen battery, reliable multi-gas OEM solution, compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Mainstream mode can simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide, and anesthetic gas, as well as respiratory rate. The types of anesthetic gas measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The data can be measured within 4 seconds after powering on. It is suitable for adults, children, and newborns, with excellent cost performance and low cost.
  • Automatic pressure compensation. There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for the temperature range of - 5-50 °C and in the range of 0 - 20%.
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare