New

MIRI II-12 Multiroom Incubator

$0.00

Shipped From Abroad

The Esco Medical MIRI® II-12 Multiroom Incubator is intended to be used to provide a stable culture environment at or near body temperature and CO2 and N2 gases for the development of gametes and embryos during In Vitro Fertilization (IVF) and Assisted Reproduction Technology (ART) treatments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Esco Medical

Description

MIRI II-12 Multiroom Incubator

To ensure maximum performance and an environment with the least amount of stress for embryos, the Esco MIRI® II-12 Multiroom Incubator dedicates one chamber for each patient and has 24 completely separate PID temperature controllers.

The chambers are separate from one another and do not affect each other’s temperatures in any way. There is no effect on the remainder of the system from any disruption in one chamber, such as a temperature reduction after opening the lid. The temperature in the culture chambers and the lids can be controlled and regulated as well. The top and the bottom of each chamber are separated with a PET layer so that the lid temperature would not affect the bottom.

For validation purposes, each compartment has a PT-1000 sensor built in. The circuitry is separated from the unit’s electronics, so it remains a truly separate validation system.

The incubator needs 100% CO2 and 100% N2 to control the CO2 and O2 concentrations in the culture chambers. A dual-beam infra-red CO2 sensor with extremely low drift rates controls the CO2 levels. On the other hand, a chemical, medical-grade oxygen sensor controls the levels of O2 in the system.

CO2 recovery takes an average of 3 minutes after opening the lid.* The MIRI® II-12 incubator is fitted with 12 gas sample ports that allow the user to validate gas concentration by sampling gas from the individual compartment.

The incubator also features a recirculated gas system where gas is continuously put into the compartment and taken out at the same rate. Gas is cleaned via a 254 nm UVC light with direct gas contact between the bulb and gas. The UVC light has filters that inhibit any 185 nm radiation that would produce dangerous ozone. The filters are located under the UVC light. The complete gas repletion in the system takes less than 5 minutes.

The high-performance CO2 and O2 sensors and built-in gas mixer enable precise adjustment of the gas phase composition and environment within the chambers.
Pure gas is used with the MIRI® II-12. Incubator steady-state gas conditions can be reached when 100% CO2 and N2 are used. This is crucial because it will maintain the pH during embryo development.
The incubator has a complete gas control system that consists of the following:

 

  1. Pressure regulator (preventing dangerous gas pressure problems)
  2. Gas flow sensors (actual consumption can be accumulated)
  3. Gas pressure sensors (allow the user to know the pressure, and the variation can be logged to avoid dangerous conditions)
  4. Gas filters (to prevent valve problems)
Petri dish location: Found in a compartment that is easy to reach and safe because of the compartment numbering and the ability to write on the white lid with a pen.
The software: It runs on the built-in touchscreen in the MIRI II-12 version. The software contains logging functions for long-term data logging and storage.
USB module: This enables the quality control data to be transferred for off-site evaluation. The performance of such allows the manufacturer to provide a valuable service to the customers.
A pH sensor port: The user can plug any standard BNC pH probe into the unit and measure the pH in the samples at will.
Features

Heated Lid

Prevents condensation, enhances consistency throughout each chamber, and improves temperature regulation and recovery.

Heated Bottom

Allows for reliable temperature regulation by providing direct heat transfer to the culture dishes.

Fast Recovery

The quick recovery of temperature and gas characteristics after opening a chamber is a significant advantage when utilizing the MIRI® II-12 multiroom incubator.

Stress-free Validation of Chamber Parameters

For gas and temperature validation, the MIRI® II-12 can be connected to an external device such as the Esco MIRI® GA. The primary circuitry is fully separate from the built-in PT1000 temperature sensors. Additionally, all 6 or 12 chambers have gas sampling ports.

Intuitive Touchscreen Controls

Practitioners of IVF work with priceless, delicate, and sensitive embryos, and frequently, the smallest variables have a significant impact. The large touchscreen display on the MIRI® II-12 is used to concurrently control and monitor crucial parameters, such as temperature and gas concentration, and provide visual and audio alarms to indicate dangerous conditions, signify critical situations, and enable users to simultaneously manage and monitor key parameters (temperature, gas concentration, etc).
It boasts a sizable display that is clear from a distance, and because it is a PC, it is loaded with many capabilities to make life in the lab simpler. There is a possibility to connect an external monitor via an HDMI connector on the back of the unit to see the incubation parameters from a more significant distance. The glass lid tops may also be written on, which is a great organizational function.

 

User-Friendly and Full-Featured Data Logging System

One computer can control and connect to multiple machines. The machine’s real-time parameters can all be simply viewed in the MIRI® II-12’s built-in touchscreen PC. These parameters include every temperature and gas concentration point, as well as the set points for all gas input pressures and flow rates. Graphs are also available for viewing that show all machine performance information, including alerts, which are continuously documented. Weekly reports are also generated automatically by the data logger, making it more user-friendly.

Heating Optimization Plates

A heating optimization plate is included in each chamber to help heat transfer directly to the culture dishes. Each chamber contains inserts that suit different-sized dishes.

Specifications
Overall dimensions (W x D x H) 740 x 575 x 215 mm (29.1 x 22.6 x 8.5”)
Net Weight 47 kg  (99.2 lbs)
Material Mild steel / Aluminum / PET / Stainless steel
Power supply 115V 60Hz or 230V 50Hz
Power consumption 500W
Temperature Control Range 25.0 – 40.0 °C
*CO2 Gas Consumption < 2 liters per hour
**N2 Gas Consumption < 12 liters per hour
CO2 Control Range 3.0% – 10.0%
O2 Control Range 5.0% – 10.0%
Gas Input Pressure 0.4 – 0.6 bar (5.80 – 8.70 PSI)
Operating Altitude Up to 2000 meters (6560 feet or 80kPa – 106kPa)
Shipping weight 57 kg (121.3 lbs) (Including the pallet’s weight)
Shipping dimension 890 x 710 x 480 mm (35 x 28 x 18.9”) (device on the pallet)

Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “MIRI II-12 Multiroom Incubator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMIRI II-12 Multiroom Incubator removeEppendorf Pipette Tip 20ul Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeEppendorf Minispin Centrifuge removePlastic Urine Container Per Pack remove
NameMIRI II-12 Multiroom Incubator removeEppendorf Pipette Tip 20ul Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeEppendorf Minispin Centrifuge removePlastic Urine Container Per Pack remove
ImageEppendorf Pipette Tip 20ul Per PackAvalun 48 INR Microcuvette
SKUSF1033560084-136SF1033560060-2SF1033560084-74SF1033560084-116SF1033560084-106
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$8.20

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad The Esco Medical MIRI® II-12 Multiroom Incubator is intended to be used to provide a stable culture environment at or near body temperature and CO2 and N2 gases for the development of gametes and embryos during In Vitro Fertilization (IVF) and Assisted Reproduction Technology (ART) treatments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
MIRI II-12 Multiroom Incubator
To ensure maximum performance and an environment with the least amount of stress for embryos, the Esco MIRI® II-12 Multiroom Incubator dedicates one chamber for each patient and has 24 completely separate PID temperature controllers. The chambers are separate from one another and do not affect each other's temperatures in any way. There is no effect on the remainder of the system from any disruption in one chamber, such as a temperature reduction after opening the lid. The temperature in the culture chambers and the lids can be controlled and regulated as well. The top and the bottom of each chamber are separated with a PET layer so that the lid temperature would not affect the bottom. For validation purposes, each compartment has a PT-1000 sensor built in. The circuitry is separated from the unit's electronics, so it remains a truly separate validation system. The incubator needs 100% CO2 and 100% N2 to control the CO2 and O2 concentrations in the culture chambers. A dual-beam infra-red CO2 sensor with extremely low drift rates controls the CO2 levels. On the other hand, a chemical, medical-grade oxygen sensor controls the levels of O2 in the system. CO2 recovery takes an average of 3 minutes after opening the lid.* The MIRI® II-12 incubator is fitted with 12 gas sample ports that allow the user to validate gas concentration by sampling gas from the individual compartment. The incubator also features a recirculated gas system where gas is continuously put into the compartment and taken out at the same rate. Gas is cleaned via a 254 nm UVC light with direct gas contact between the bulb and gas. The UVC light has filters that inhibit any 185 nm radiation that would produce dangerous ozone. The filters are located under the UVC light. The complete gas repletion in the system takes less than 5 minutes.
The high-performance CO2 and O2 sensors and built-in gas mixer enable precise adjustment of the gas phase composition and environment within the chambers.
Pure gas is used with the MIRI® II-12. Incubator steady-state gas conditions can be reached when 100% CO2 and N2 are used. This is crucial because it will maintain the pH during embryo development.
The incubator has a complete gas control system that consists of the following:
 
  1. Pressure regulator (preventing dangerous gas pressure problems)
  2. Gas flow sensors (actual consumption can be accumulated)
  3. Gas pressure sensors (allow the user to know the pressure, and the variation can be logged to avoid dangerous conditions)
  4. Gas filters (to prevent valve problems)
Petri dish location: Found in a compartment that is easy to reach and safe because of the compartment numbering and the ability to write on the white lid with a pen.
The software: It runs on the built-in touchscreen in the MIRI II-12 version. The software contains logging functions for long-term data logging and storage.
USB module: This enables the quality control data to be transferred for off-site evaluation. The performance of such allows the manufacturer to provide a valuable service to the customers.
A pH sensor port: The user can plug any standard BNC pH probe into the unit and measure the pH in the samples at will.
Features

Heated Lid

Prevents condensation, enhances consistency throughout each chamber, and improves temperature regulation and recovery.

Heated Bottom

Allows for reliable temperature regulation by providing direct heat transfer to the culture dishes.

Fast Recovery

The quick recovery of temperature and gas characteristics after opening a chamber is a significant advantage when utilizing the MIRI® II-12 multiroom incubator.

Stress-free Validation of Chamber Parameters

For gas and temperature validation, the MIRI® II-12 can be connected to an external device such as the Esco MIRI® GA. The primary circuitry is fully separate from the built-in PT1000 temperature sensors. Additionally, all 6 or 12 chambers have gas sampling ports.

Intuitive Touchscreen Controls

Practitioners of IVF work with priceless, delicate, and sensitive embryos, and frequently, the smallest variables have a significant impact. The large touchscreen display on the MIRI® II-12 is used to concurrently control and monitor crucial parameters, such as temperature and gas concentration, and provide visual and audio alarms to indicate dangerous conditions, signify critical situations, and enable users to simultaneously manage and monitor key parameters (temperature, gas concentration, etc).
It boasts a sizable display that is clear from a distance, and because it is a PC, it is loaded with many capabilities to make life in the lab simpler. There is a possibility to connect an external monitor via an HDMI connector on the back of the unit to see the incubation parameters from a more significant distance. The glass lid tops may also be written on, which is a great organizational function.
 

User-Friendly and Full-Featured Data Logging System

One computer can control and connect to multiple machines. The machine's real-time parameters can all be simply viewed in the MIRI® II-12’s built-in touchscreen PC. These parameters include every temperature and gas concentration point, as well as the set points for all gas input pressures and flow rates. Graphs are also available for viewing that show all machine performance information, including alerts, which are continuously documented. Weekly reports are also generated automatically by the data logger, making it more user-friendly.

Heating Optimization Plates

A heating optimization plate is included in each chamber to help heat transfer directly to the culture dishes. Each chamber contains inserts that suit different-sized dishes.
Specifications
Overall dimensions (W x D x H) 740 x 575 x 215 mm (29.1 x 22.6 x 8.5”)
Net Weight 47 kg  (99.2 lbs)
Material Mild steel / Aluminum / PET / Stainless steel
Power supply 115V 60Hz or 230V 50Hz
Power consumption 500W
Temperature Control Range 25.0 - 40.0 °C
*CO2 Gas Consumption < 2 liters per hour
**N2 Gas Consumption < 12 liters per hour
CO2 Control Range 3.0% - 10.0%
O2 Control Range 5.0% - 10.0%
Gas Input Pressure 0.4 - 0.6 bar (5.80 - 8.70 PSI)
Operating Altitude Up to 2000 meters (6560 feet or 80kPa - 106kPa)
Shipping weight 57 kg (121.3 lbs) (Including the pallet’s weight)
Shipping dimension 890 x 710 x 480 mm (35 x 28 x 18.9”) (device on the pallet)
Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare