Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter

Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.

Economic

An Economic Multi-gas monitor that supports safe agent administration.

  • Automatic atmospheric pressure compensation

Automatically adjust atmospheric pressure compensation according to altitude conditions

  • Reliable and Accurate

Based on Kingst’s mature technology of infrared gas analysis.

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 – 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

SpO2 (optional) Range: 0 – 100%

Accuracy: ±2% for SpO2 range from 70 – 100%, 70% of the following does not require

Pulse Rate (optional) Range: 30 – 250bpm

Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min;

41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)

Rise time CO2 is less than 200ms;

N2O is less than 300ms;

Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

The high alarm limits of SpO2:off

The low alarm limits of SpO2:50-100%

The high alarm limits of Pulse Rate:70-250 bpm

The low alarm limits of Pulse Rate:30-100 bpm

Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended

 

Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure-H”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure-H removeSiare Morpheus LT Anaesthetic Machine removeElastomeric Pump (Disposable Infusion Pump) with PCA removeHersill Genesis Anaesthetic Machine removeSiare Morpheus E Anaesthetic Machine removeAgary I.V. Cannula remove
NameMultigas Monitor AneSure-H removeSiare Morpheus LT Anaesthetic Machine removeElastomeric Pump (Disposable Infusion Pump) with PCA removeHersill Genesis Anaesthetic Machine removeSiare Morpheus E Anaesthetic Machine removeAgary I.V. Cannula remove
ImageHersill Genesis Anaesthetic MachineAnesthetic Machine
SKUSF1033560130170-13SF1033560101- 3SF1033560084-18SF1033560450-1SF1033560101-1SF1033560084-221
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$7.10

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The MORPHEUS E is an anaesthesia machine with electronic flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients. Economic
An Economic Multi-gas monitor that supports safe agent administration.
  • Automatic atmospheric pressure compensation
Automatically adjust atmospheric pressure compensation according to altitude conditions
  • Reliable and Accurate
Based on Kingst's mature technology of infrared gas analysis.
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V - 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 - 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
SpO2 (optional) Range: 0 - 100% Accuracy: ±2% for SpO2 range from 70 - 100%, 70% of the following does not require
Pulse Rate (optional) Range: 30 – 250bpm Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min; 41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)
Rise time CO2 is less than 200ms; N2O is less than 300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min The high alarm limits of SpO2:off The low alarm limits of SpO2:50-100% The high alarm limits of Pulse Rate:70-250 bpm The low alarm limits of Pulse Rate:30-100 bpm
Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended
 
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;
The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. LUNG VENTILATOR The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02. Operative Modes: MAN VC-VC PCV-APCV APCV P -SIMV V- SIMV Measured parameters: PAW RATE VM - VTE T INSP Fi02 MANUAL VENTILATION SYSTEM The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system. BREATHING SYSTEM The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
The MORPHEUS E is an anaesthesia machine with Electronic Flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS E is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto.  
Click Here To Download Catalogue
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare