Description

Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter

Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.

Economic

An Economic Multi-gas monitor that supports safe agent administration.

  • Automatic atmospheric pressure compensation

Automatically adjust atmospheric pressure compensation according to altitude conditions

  • Reliable and Accurate

Based on Kingst’s mature technology of infrared gas analysis.

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 – 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

SpO2 (optional) Range: 0 – 100%

Accuracy: ±2% for SpO2 range from 70 – 100%, 70% of the following does not require

Pulse Rate (optional) Range: 30 – 250bpm

Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min;

41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)

Rise time CO2 is less than 200ms;

N2O is less than 300ms;

Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

The high alarm limits of SpO2:off

The low alarm limits of SpO2:50-100%

The high alarm limits of Pulse Rate:70-250 bpm

The low alarm limits of Pulse Rate:30-100 bpm

Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended

 

Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure-H”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure-H removeLab/Ward Coat removeBistos BT-770-12.1" Touchscreen Patient Monitor removeTimesco Eclipse McCoy Laryngoscope Set removeSpinal Epidural Pack removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
NameMultigas Monitor AneSure-H removeLab/Ward Coat removeBistos BT-770-12.1" Touchscreen Patient Monitor removeTimesco Eclipse McCoy Laryngoscope Set removeSpinal Epidural Pack removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
ImageBistos BT-770-12.1" Touchscreen Patient MonitorTimesco Eclipse McCoy Laryngoscope Set
SKUSF1033560130170-13SF1033560084-222SF1033560059-1SF1033560084-54SF1033560084-25SF1033560084-18
Rating
Price

$0.00

$11.00

$902.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients. Economic
An Economic Multi-gas monitor that supports safe agent administration.
  • Automatic atmospheric pressure compensation
Automatically adjust atmospheric pressure compensation according to altitude conditions
  • Reliable and Accurate
Based on Kingst's mature technology of infrared gas analysis.
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V - 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 - 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
SpO2 (optional) Range: 0 - 100% Accuracy: ±2% for SpO2 range from 70 - 100%, 70% of the following does not require
Pulse Rate (optional) Range: 30 – 250bpm Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min; 41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)
Rise time CO2 is less than 200ms; N2O is less than 300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min The high alarm limits of SpO2:off The low alarm limits of SpO2:50-100% The high alarm limits of Pulse Rate:70-250 bpm The low alarm limits of Pulse Rate:30-100 bpm
Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended
 
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar