/ /

Multigas Monitor AneSure Mini

$1,815.00

Shipped From Abroad

AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-14
Brands:: Kingst

Description

Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight

Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

  • Large Character Mode

The data can be seen from 5 meters away;

Turn on the unit, and it is ready to use instantly with no need to calibrate;

Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.

  • Firm And Durable

Suitable for various medical environments (field, helicopter, etc.)

 

Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 – 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

Rise time CO2 is less than70ms;

N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric)

1ml (Neonate)

Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery

 

Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure Mini”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure Mini removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeTimesco Eclipse McCoy Laryngoscope Set removeKIT FOR THORACENTESIS & PARACENTESIS removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine remove
NameMultigas Monitor AneSure Mini removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeTimesco Eclipse McCoy Laryngoscope Set removeKIT FOR THORACENTESIS & PARACENTESIS removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine remove
ImageTimesco Eclipse McCoy Laryngoscope Set
SKUSF1033560130170-14SF1033560096-4SF1033560084-221SF1033560084-54SF1033560130101-5SF1033560011-12
Rating
Price

$1,815.00

$0.00

$7.10

$0.00

$0.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight
Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
  • Large Character Mode
The data can be seen from 5 meters away; Turn on the unit, and it is ready to use instantly with no need to calibrate; Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.
  • Firm And Durable
Suitable for various medical environments (field, helicopter, etc.)  
Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 - 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
Rise time CO2 is less than70ms; N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min
Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric) 1ml (Neonate)
Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery
 
Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue

KIT FOR THORACENTESIS & PARACENTESIS

The device is used to drain ascitic fluid and pleural liquid, it contains everything necessary for performing thoracentesis and paracentesis procedure (needles  syringe and collection bag). Products are customized upon request.  
Reference Description Qty per box
H92000E TORASET 1-55 30 pcs
H92010E TORASET 1-80 30 pcs
H92020E TORASET 1-VER 30 pcs
H92030E TORASET2-55 30 pcs
H92040E TORASET 2-80 30 pcs
H92050E TORASET 2-VER 30 pcs
H92001E TORAMATIC 1-55 30 pcs
H92011E TORAMATIC 1-80 30 pcs
H92021E TORAMATIC 1-VER 30 pcs
H92120E PARASET 2 30 pcs
H92160E PARASET 5 20 pcs
H92200E PARASET 8 20 pcs
H92240E PARASET 12 15 pcs
 
Click here to download Catalogue
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare