Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight

Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

  • Large Character Mode

The data can be seen from 5 meters away;

Turn on the unit, and it is ready to use instantly with no need to calibrate;

Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.

  • Firm And Durable

Suitable for various medical environments (field, helicopter, etc.)

 

Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 – 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

Rise time CO2 is less than70ms;

N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric)

1ml (Neonate)

Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery

 

Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure Mini”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure Mini removeLittman Stethoscope removeHersill Genesis Anaesthetic Machine removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeTimesco Orion Laryngoscope Set remove
NameMultigas Monitor AneSure Mini removeLittman Stethoscope removeHersill Genesis Anaesthetic Machine removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeTimesco Orion Laryngoscope Set remove
ImageLittman StethoscopeHersill Genesis Anaesthetic MachineTimesco Orion Laryngoscope Set
SKUSF1033560084-5SF1033560450-1SF1033560096-4SF1033560084-221SF1033560084-53
Rating
Price

$1,815.00

$13.20

$0.00

$0.00

$7.10

$98.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supplies single-use sets as a ready to use a system containing one blade and one handle in a clear pouch.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight
Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
  • Large Character Mode
The data can be seen from 5 meters away; Turn on the unit, and it is ready to use instantly with no need to calibrate; Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.
  • Firm And Durable
Suitable for various medical environments (field, helicopter, etc.)  
Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 - 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
Rise time CO2 is less than70ms; N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min
Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric) 1ml (Neonate)
Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery
 
Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.
Littman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supply single use sets as a ready to use system containing one blade and one handle in a clear pouch.
  • A clear, impact resistant polypropylene case, which allows the contents to be clearly visible.
  • Designed to hold Macintosh 2, 3 and 4 blades and a laryngoscope handle.
  • There is a unique flexible button on the lid to allow EES engines and handles to be tested without opening the case.
  • Contains BioCote silver phosphate glass antimicrobial technology to preserve the surface and prevent degradation caused by microbial growth.
  • Set consists of Orion handle, Orion Mac 4, 3 & 2 blades
  • CE marked
  • Latex free
  • Extensive guarantees
  • ISO 7376 compatible
  • Supplied with multilingual instructions