/ /

ND: YAG Laser

$0.00

Shipped From Abroad

Nd: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope..

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013028
Brands:: Vision Star

Description

ND: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope. The energy(ND: YAG Laser) is concentrated and focused on a spot of about 30μm, producing light-induced explosion effect in the action of such a high optical power density, to dissociate ocular tissue rapidly for a purpose of surgery.

Specifications of ND: YAG Laser :

Laser Type ND:YAG
Wavelength 1064nm ± 5nm
Mode Q-Switch  (multi-mode)
Pulse Output Single-pulse, dual-pulse and three-pulse
Time characteristics of the laser pulse output
Pulse Width 4.5ns ± 10%
Pulse Repetition Rate 2.5Hz
Duration of laser pulse sequence dual-pulse≤30μs; three-pulse≤50μs
Output Energy
1 pulse maximum output 11mJ
2 pulse maximum output 9mJ
3 pulse maximum output 28mJ
Output Energy Regulation 100%~6% adjustable by 7 steps
Cone Angle 18°
Spot Size 30um
Aiming Beam Wavelength 630-680nm
Aiming Output Power PC < 0.4mW

Reviews

There are no reviews yet.

Be the first to review “ND: YAG Laser”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsND: YAG Laser removeUrine Analyzer removePedal Bin removeSyringe Needle Destroyer removeSyringe Bulb removeSIGNERS SUPiA X-ray Digitizer ( CR Scanner) remove
NameND: YAG Laser removeUrine Analyzer removePedal Bin removeSyringe Needle Destroyer removeSyringe Bulb removeSIGNERS SUPiA X-ray Digitizer ( CR Scanner) remove
ImageSIGNERS SUPiA X-ray Digitizer
SKUSF103356013028SF1033560084-224SF1033560084-201SF1033560084-206SF1033560084-205SF1033560050-01
Rating
Price

$0.00

$540.00

$17.00

$157.00

$1.99

$6,930.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Nd: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope..
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Brushed Steel Finish
  • 3L capacities
  • Gripped pedal
  • Easy clean plastic bucket
  • Lip for hiding excess bag
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Shipped from Abroad SUPiA made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability.

Delivery & Availability:

Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentND: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope. The energy(ND: YAG Laser) is concentrated and focused on a spot of about 30μm, producing light-induced explosion effect in the action of such a high optical power density, to dissociate ocular tissue rapidly for a purpose of surgery.

Specifications of ND: YAG Laser :

Laser Type ND:YAG
Wavelength 1064nm ± 5nm
Mode Q-Switch  (multi-mode)
Pulse Output Single-pulse, dual-pulse and three-pulse
Time characteristics of the laser pulse output
Pulse Width 4.5ns ± 10%
Pulse Repetition Rate 2.5Hz
Duration of laser pulse sequence dual-pulse≤30μs; three-pulse≤50μs
Output Energy
1 pulse maximum output 11mJ
2 pulse maximum output 9mJ
3 pulse maximum output 28mJ
Output Energy Regulation 100%~6% adjustable by 7 steps
Cone Angle 18°
Spot Size 30um
Aiming Beam Wavelength 630-680nm
Aiming Output Power PC < 0.4mW
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
  • Brushed Steel Finish
  • 3L capacities
  • Gripped pedal
  • Easy clean plastic bucket
  • Lip for hiding excess bag
Height 260mm 10.24inches
Width 170mm 6.69inches
Depth 225mm 8.86inches
Weight 0.63kg 1.39lb
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
  • Disposable syringe for aspiration and irrigation
  • Ideal for suctioning a newborn's airway
  • Sterile
  • Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
  • Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
  • Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
  • Nasal aspirator to clear nose in babies.
  • Can be used to wash ulcers.
SUPiA X-ray Digitizer made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability FEATURE Rigid Type • No damage or scratch on image plates during scanning & erasing • Scanning & Erasing without a roller • No cut-off image during winter and cold period Durability • Extremely simple structure design • Strong aluminum base plate • Flip covers preventing dust from inside scanner Barcode System • Automatically recognising cassette sizes(14x17", 10x12", 18x24cm) by barcode reader Compact & lightweight design
  • Very small and compatible CR on desktop (only 63.5cm)
  • Only 21.5kg (47.4lbs)
Cassette Strong structure • Strong enough against external impact • Totally metal frame • Enduring under 150kg on cassette Featherlight • 14x17" : 2.05kg 10x12" : 0.99kg 18x24cm : 0.75kg Dust free & Easy cleaning • Easy to clean up dust on IPs • Prevent dust from outside User friendly design • Various colors 14x17"(Green), 10x12"(Blue), 18x24cm(Pink)) • Barcode label   TECHNICAL SPECIFICATION
  SUPiA Specifications
Cassette SUPiA CR Cassette 14x17 (inch) SUPiA CR Cassette 10x12 (inch) SUPiA CR Cassette 18x24 (cm)
Throughput Up to 94 IPs/hour (14x17"/160μm)
Slots Single Cassette feed
Dimensions (W x D x H) 436 x 636 x 196mm
Weight 21.5kg (47.4lbs)
Grayscale Resolution Acquisition : 16 bits per pixel Display : 12 bits per pixel
Power Supply Conditions Single Phase 50 ~ 60Hz AC 90 ~ 264V
Network 100 MBit
PC Connection USB 2.0
Computer Min. requirements

OS : Win 7 or 10

CPU : Intel i5

RAM : 4GB

Graphic Card : Intel HD 2500

HDD : 500GB

Monitor : FHD 1920 x 1080

Operating conditions Temperature : 10 ~ 30ËšC Humidity : 15 ~ 85% RH
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare