ND: YAG Laser

$0.00

Shipped From Abroad

Nd: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope..

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013028
Brands:: Vision Star

Description

ND: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope. The energy(ND: YAG Laser) is concentrated and focused on a spot of about 30μm, producing light-induced explosion effect in the action of such a high optical power density, to dissociate ocular tissue rapidly for a purpose of surgery.

Specifications of ND: YAG Laser :

Laser Type ND:YAG
Wavelength 1064nm ± 5nm
Mode Q-Switch  (multi-mode)
Pulse Output Single-pulse, dual-pulse and three-pulse
Time characteristics of the laser pulse output
Pulse Width 4.5ns ± 10%
Pulse Repetition Rate 2.5Hz
Duration of laser pulse sequence dual-pulse≤30μs; three-pulse≤50μs
Output Energy
1 pulse maximum output 11mJ
2 pulse maximum output 9mJ
3 pulse maximum output 28mJ
Output Energy Regulation 100%~6% adjustable by 7 steps
Cone Angle 18°
Spot Size 30um
Aiming Beam Wavelength 630-680nm
Aiming Output Power PC < 0.4mW

Reviews

There are no reviews yet.

Be the first to review “ND: YAG Laser”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsND: YAG Laser removeStandiometer removeOPTIKA B-383DK Trinocular Darkfeld Microscope removeWalker removeSyringe Bulb removeUrine Analyzer remove
NameND: YAG Laser removeStandiometer removeOPTIKA B-383DK Trinocular Darkfeld Microscope removeWalker removeSyringe Bulb removeUrine Analyzer remove
ImageOPTIKA B-383DK Trinocular Darkfeld Microscope
SKUSF103356013028SF1033560084-219SF1033560098-14SF1033560084-223SF1033560084-205SF1033560084-224
Rating
Price

$0.00

$64.00

$0.00

$15.00

$1.99

$540.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Nd: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope..
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad B-383DK - Darkfield Microscope Laboratory upright microscope for brightfield and darkfield observations with N-PLAN objectives (and W-PLAN 100x with iris) for biology and especially darkfield fresh blood analysis and the exclusive X-LED3 illumination system. The special condenser with integrated, exclusive X-LED3 illuminator replaces any other external and expensive lighting source required for these applications and is ideal for great-looking, rich and high-quality specimen view. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Material: Aluminium
  • Age Group: Adult Walkers
  • Height: 37 Inch
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentND: YAG Laser System for Ophthalmology produces 1064nm wavelength laser pulse. The laser pulse and dual-spot aiming beam can position precisely on the ocular tissue to be treated through slit-lamp microscope. The energy(ND: YAG Laser) is concentrated and focused on a spot of about 30μm, producing light-induced explosion effect in the action of such a high optical power density, to dissociate ocular tissue rapidly for a purpose of surgery.

Specifications of ND: YAG Laser :

Laser Type ND:YAG
Wavelength 1064nm ± 5nm
Mode Q-Switch  (multi-mode)
Pulse Output Single-pulse, dual-pulse and three-pulse
Time characteristics of the laser pulse output
Pulse Width 4.5ns ± 10%
Pulse Repetition Rate 2.5Hz
Duration of laser pulse sequence dual-pulse≤30μs; three-pulse≤50μs
Output Energy
1 pulse maximum output 11mJ
2 pulse maximum output 9mJ
3 pulse maximum output 28mJ
Output Energy Regulation 100%~6% adjustable by 7 steps
Cone Angle 18°
Spot Size 30um
Aiming Beam Wavelength 630-680nm
Aiming Output Power PC < 0.4mW
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
Observation mode: Brightfield, oil immersion darkfield. Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating. Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 W-PLAN 100x/1.25 (oil) with iris All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Brightfield condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Darkfieldfield condenser: Darkfield N.A. 1.36 (oil immersion) with built-in X-LED3. Transmitted illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
Material Aluminium
Age Group Adult Walkers
Height 37 Inch
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
  • Disposable syringe for aspiration and irrigation
  • Ideal for suctioning a newborn's airway
  • Sterile
  • Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
  • Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
  • Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
  • Nasal aspirator to clear nose in babies.
  • Can be used to wash ulcers.
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare