Neonatal Transport Incubator BLF-2001G
Features
- Humidity servo (0-95%)
- 3 litres distilled and residual water reservoirs
- Air temperature servo control w/ override (25-39 oC)
- Glass-like transparent single wall hood, x-ray compatible
- Hood with front access door
- Hood with 4 noiseless, easy to open hand ports / windows
- Hood with 2 iris ports / windows
- Hood with 6 tube ports
- Cradle with anti-decubitus mattress, x-ray compatible
- Space for x-ray cassette under the cradle
- Mechanical one step cradle tilting, up to 12 degrees
- Heavy duty stand with 4 castors (2 lockable)
- Instrument shelf on the stand
- Protector and instrument holder rails on each side
- HEPA 13 air filter
- State-of-the-art microprocessor controller
- 5” bi-colour LCD display
- Water resistant, foil-covered keypad with lock
- Test button / Self test / Silence / Reset button
- Display of heating intensity, date, set and actual values
- 3/24/170 hours trends
- Visual and audible alarms and backup sensors
- Continuous self-test function during operation
- Test button / Self test / Silence / Reset button
- RS-232 connector
- 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Properties
- Exceptional Safety
The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards.
Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor) / Humidifying / Technical fault / Mains fault / Low limit off / Low limit air / High limit air / – Acoustic and yellow or red colored messages/signs on the LCD in case of alarm or warming
- Easy Access
The hood has six fully transparent windows (with iris opening upon request) and a large (upon request two) door(s). An X-ray cassette can be inserted under the cradle or on a cassette holder tray (optional). The cradle with the baby can be placed into an inclined position (even electrically upon request; optional), and the baby can be removed from the incubator safely and quickly together with the cradle.
- Air Curtain
ln the hood the air streams along the longitudinal axis of the baby’s body. When the door is opened, an air curtain develops in the door. The hood of the unit may be single, double or triple walled (optional).
- Easy Operation
The incubators are equipped with foil-covered keyboards and graphic LCD displays. Settings are easy to understand having the lowest possible number of controls. Set and real-time measured values are constantly shown on the LCD display.
- Silent Operation
The noise level in the hood is below 45 dBA (40 dBA as option). The opening and closing of windows is absolutely noiseless. The air flow rate is well below the value allowed by the relevant standards.
- Variable oxygen supply
Oxygen supply in the hood is controlled by a rotameter between 21-40% (optional). An electronic oxygen servo unit provides higher oxygen concentration for more intensity between 21-75% (optional). The incubators may be ordered also with head hood and with warmed humidified oxygen servo control (21-95%) (optional).
- Comfort
ln the incubator, the baby’s weight is measured with high accuracy by an electronic scale located under the cradle, the measured value is shown on the graphic display, while data are stored (optional). The height of the lying surface can be made electronically adjustable upon request (optional).
- Micro-computer control
BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional).
The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:
- temperature of air in the hood
- humidity of air in the hood
- baby’s skin temperature (optional)
- oxygen concentration (optional)
- weight (optional)
- second body temperature (optional)
The temperature control ranges of the incubator are as follows:
- in normal mode of operation in the case of ‘air control’ 27-37°C in the case of skin control 34-36°C.
- ln ‘override’ operation in the case of ‘air control’ 37-39°C, in the case of ‘skin control’ 36-38°C.
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION) | |
---|---|
Height / Packing | 13 2/152 cm (52/60 in) |
Width / Packing | 85/95 cm (33/37 in) |
Depth / Packing | 60/70 cm (24/28 in) |
Weight / Packing | 70 kg (154 lbs) |
Mains voltage | 2 20/230V ± 10% (default), 110/120V ± 10% ( upon request) |
Nominal frequency | 50/60Hz |
Nominal power consumption | 420VA |
Operating ambient temperature range | +20°C – +30°C (68°F – 86°F) |
Storage/transport ambient temperature range | -40°C – 70°C (-40°F – 158°F) |
Operating (Storage) ambient RH range | 30% – 90% (10% – 100%) |
Operating (Storage) air pressure range | 700 hPa – 1060 hPa (500 hPa – 1060 hPa) |
HOOD SPECIFICATIONS | |
Access door opening height | 30 cm(12 in) |
Mattress tray size | 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in) |
Mattress to hood height | 36 cm (14 in) default, up to 45 cm (18 in) as option |
Mattress size | 70 x 40 cm (27,6 x 15,75 in) / Optional 70 x 46 cm (27,6 x 18,11 in) |
TEMPERATURE CONTROL MODES | |
Temperature control modes | Air (standard) / Skin (option) |
Temperature display range (Air/Skin mode) | 0.0°C (32.0° F) to 50.0°C ( 12 2.0°F) |
Air mode control temperature range | 0.0°C (68.0°F) to 37.0°C (98.6°F), in 0.1°C increments |
Air mode control override temperature range | 37.0°C (98.6° F) to 39.0°C (102.2° F), in 0.1°C increments |
Skin mode control temperature range | 34.0° ( (93.2° F) to 36.0° ( (96.8°F), |
Skin mode control override temperature range | 36.0° (96.8° F) to 38.0° (100.4° F), in 0.1°C increments |
Peripherial skin / Rectal temperature monitoring | Yes |
PERFORMANCE | |
Air flow velocity across mattress | under 10 cm/sec |
Temperature rise time at 22 °C (72° F) ambient | under 20 min |
Temperature variability | under 0.5°C (0.9°F) |
Temperature uniformity on the surface of the mattress | under 0.8°C (1.4°F) |
Correlation of the indicated air temperature with the actual incubator temperature | under 0.8°C (1.4°F) |
Operating noise level in hood | under 45 dBA (40 dBA as option) |
Carbon Dioxide (CO) level (per EN60601-2-19) | under 0,2% |
Micro air intake filter | HEPA 13 – 99 ,95% |
Particle size removal | 0.3 micron |
HUMIDITY SERVO CONTROL | |
Humidity control range | 30% to 95% in 1 % increments |
Humidity control operating time without refilling | 55 hours max. at 85% RH and 36°C (97° F) in Air Mode |
Humidity control reservoir capacity | 3000 ml |
Humidity display accuracy | + 10% RH (between 10% and 90% at 20° c (68° F) to 40° c (104°F)) |
OXYGEN SERVO CONTROL | |
Oxygen control range | 21 % to 75%/95% (hood/head hood) |
Oxygen control accuracy of full scale | ± 3% |
Oxygen display accuracy (100% calibration) | ± 3% |
Oxygen display accuracy (21 % calibration) | ± 3% |
Oxygen display resolution | 1% |
WEIGHING SCALE | |
Weight range | 0 to 10 kg (22 lbs) |
Weight display resolution | 1 gr or 1 oz |
Weight accuracy | up to 5 kg + 2 gr, over 5 kg + 5 gr |
DEVICE CLASSIFICATION | |
Protection class | Class 1, Type BF, continuous operation |
Ingress of liquids | IP20 |
TREND PARAMETERS | |
3/24/170-hour trend | Air temperature / Skin temperature / Peripherial temperature / Relative humidity / Oxygen concentration / SpO2 (Pulse Oximeter) / Heater power / Weight |
Quick Comparison
Settings | Neonatal Transport Incubator BLF-2001G remove | Hospital Trolley remove | Syringe Needle Destroyer remove | Siare Morpheus LT Anaesthetic Machine remove | Walker remove | Instrument Tray remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neonatal Transport Incubator BLF-2001G remove | Hospital Trolley remove | Syringe Needle Destroyer remove | Siare Morpheus LT Anaesthetic Machine remove | Walker remove | Instrument Tray remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130129-1 | SF1033560084-237 | SF1033560084-206 | SF1033560101- 3 | SF1033560084-223 | SF1033560084-199 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $48.00 | $157.00 |
| $15.00 | $6.90 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Dimension (mm): L550 x W420 x H880 mm
Color: Grey
Material: Stainless steel
No of wheel: 4
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Neonatal Transport Incubator BLF-2001Ghttps://youtu.be/pg5CGC0Ckj4Features
Properties
BLF-2001 incubators are micro-computer controlled. When switched on, a hardware and software self-test is launched. Possible errors are indicated on the graphic display. The trends and values measured every 3 or 24 or 170 hours can be retrieved from the memory of the incubator. The incubator may be connected to an external computer (by means of a software programme to be purchased separately), enabling monitoring and remote control, as well as the saving and printing of measured values and trends (optional). The display of the BLF-2001 incubator is easy to read even from distance, indicating the following data, depending on the configuration:
Technical data
|
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
| The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs.
LUNG VENTILATOR
The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02.
Operative Modes:
MAN
VC-VC
PCV-APCV
APCV
P -SIMV
V- SIMV
Measured parameters:
PAW
RATE
VM - VTE
T INSP
Fi02
MANUAL VENTILATION SYSTEM
The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system.
BREATHING SYSTEM
The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.