  • Automatic warm-up
  • Pre-warm (33 oC) & Manual mode (0-100% in 5% increments)
  • Surface temperature servo control (30-38 oC)
  • Skin temp. servo control (32-38 oC increments 0.1 oC) with reusable sensor
  • Heavy duty stand with 4 castors (2 lockable, 150 mm)
  • Protector bumpers on each side & handle on front
  • Foldable side walls (4 pcs, height 17,5 cm) w/ name plate
  • Tube ports & measure line on side walls
  • Lying surface w/ antidecubitus mattress, x-ray compatible
  • Cradle tilting (continuous, up to 10 degrees, both direction)
  • Drawable x-ray cassette tray (35 x 65 cm)
  • Turnable head by 30 and 90 degrees both direction
  • Ceramic heaters with parabolic reflectors and protecting grid
  • Cupboard with two drawers (300x300x90 mm)
  • Gas cylinder holders (two) on the stand
  • Monitor shelves (two) & IV pole on the column
  • Dimmable halogen & LED procedure light
  • 5” LCD display with APGAR timer
  • Set / Display of date / time / temperature / trend, etc.
  • Water resistant, foil-covered keypad with lock
  • State-of-the-art microprocessor controller
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)

 

Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Adjustable / Packing 185/185-200/112 cm (72,8/72-78,7/44,1 in)
Width / Packing 120/127 cm (47,2/50 in)
Depth / Packing 71/81 cm (28/31,9 in)
Bed to Floor (fix) 87 cm (33,5 in)
Bed to Floor (adjustable) 87 – 102 cm (33,5 – 39,4 in)
Weight / Packing approx. 90/120 kg (199/265 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request)
Mains frequency 50 Hz (default), 60 Hz (upon request)
Nominal power consumption 1100W
Nominal power of ceramic heaters (2 pcs) 500 W
Operating ambient temperature range +20°C – +30°C (68oF – 86oF)
Storage/transport ambient temperature range -40oC – +70oC (-40oF – 158oF)
Operating (Storage) ambient RH range 30% – 75% (10% – 100%)
Operating (Storage) air pressure range 700 hPa – 1060 hPa (500 hPa – 1060 hPa)
LYING SURFACE (BED) SPECIFICATION
Surface size 61 x 76 cm (24 x 29,9 in)
Mattress size 60 x 75 x 2 cm (23,6 x 29,5 x 0,8 in)
Mattress to head height 80 cm (31,5 in)
TEMPERATURE CONTROL MODES
Pre-warm mode 33.0°C (91.4°F)
Manual control temperature mode 0%-100%, in 5% increments
Surface control temperature range 30.0°C (86°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin control temperature range 32.0°C (89.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Mattress heating temperature range 30.0°C (86°F) to 33.0°C (91.4°F), in 1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Temperature rise time 25 °C (77°F) ambient < 30 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.7°C (1.2°F)
Correlation of the indicated air temperature with the actual surface temperature ≤ 0.7°C (1.2°F)
Display precision of skin temperature under ±0.1°C (0.1°F)
Measuring precision of skin temperature sensor under ±0.3°C (0.5°F)
APGAR warning signal after 1 / 5 / 10 min
OXYGEN SERVO CONTROL
Oxygen control range 21% to 90% (head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21% calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 8 kg (17,1 lbs)
Weight display resolution 5 gr or 0,2 oz
Weight accuracy up to 5 kg ± 5 gr, over 5 kg ± 10 gr
Low voltage alarm
LOADING
Max. load of mattress 10 kg (22,1 lbs)
Max. load of IV pole 2 kg (4,7 lbs)
Max load of shelves 2 kg (4,7 lbs)
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IP20
Electric safety IEC 60601-1; IEC 60601-2-21
TREND PARAMETERS
3/24/170-hour trend Surface temperature, Skin temperature, Mattress temperature, Peripherial temperature, Oxygen concentration, Heater power

Reviews

There are no reviews yet.

Be the first to review “Neonatal Warming and Resuscitation Table 2100A”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeonatal Warming and Resuscitation Table 2100A removeKick About removeFirst Aid Box Aluminium Small removeWalker removeSyringe Needle Destroyer removeUrine Analyzer remove
NameNeonatal Warming and Resuscitation Table 2100A removeKick About removeFirst Aid Box Aluminium Small removeWalker removeSyringe Needle Destroyer removeUrine Analyzer remove
Image
SKUSF1033560130129-3SF1033560084-238SF1033560084-252SF1033560084-223SF1033560084-206SF1033560084-224
Rating
Price

$0.00

$28.00

$49.50

$15.00

$157.00

$540.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Material: Aluminium
  • Age Group: Adult Walkers
  • Height: 37 Inch
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/G0AjkyYOQpw  
Features
  • Automatic warm-up
  • Pre-warm (33 oC) & Manual mode (0-100% in 5% increments)
  • Surface temperature servo control (30-38 oC)
  • Skin temp. servo control (32-38 oC increments 0.1 oC) with reusable sensor
  • Heavy duty stand with 4 castors (2 lockable, 150 mm)
  • Protector bumpers on each side & handle on front
  • Foldable side walls (4 pcs, height 17,5 cm) w/ name plate
  • Tube ports & measure line on side walls
  • Lying surface w/ antidecubitus mattress, x-ray compatible
  • Cradle tilting (continuous, up to 10 degrees, both direction)
  • Drawable x-ray cassette tray (35 x 65 cm)
  • Turnable head by 30 and 90 degrees both direction
  • Ceramic heaters with parabolic reflectors and protecting grid
  • Cupboard with two drawers (300x300x90 mm)
  • Gas cylinder holders (two) on the stand
  • Monitor shelves (two) & IV pole on the column
  • Dimmable halogen & LED procedure light
  • 5” LCD display with APGAR timer
  • Set / Display of date / time / temperature / trend, etc.
  • Water resistant, foil-covered keypad with lock
  • State-of-the-art microprocessor controller
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • Test button / Self test / Silence / Reset button
  • RS-232 connector
  • 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
 
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Height / Adjustable / Packing 185/185-200/112 cm (72,8/72-78,7/44,1 in)
Width / Packing 120/127 cm (47,2/50 in)
Depth / Packing 71/81 cm (28/31,9 in)
Bed to Floor (fix) 87 cm (33,5 in)
Bed to Floor (adjustable) 87 – 102 cm (33,5 – 39,4 in)
Weight / Packing approx. 90/120 kg (199/265 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request)
Mains frequency 50 Hz (default), 60 Hz (upon request)
Nominal power consumption 1100W
Nominal power of ceramic heaters (2 pcs) 500 W
Operating ambient temperature range +20°C - +30°C (68oF – 86oF)
Storage/transport ambient temperature range -40oC - +70oC (-40oF - 158oF)
Operating (Storage) ambient RH range 30% - 75% (10% - 100%)
Operating (Storage) air pressure range 700 hPa - 1060 hPa (500 hPa - 1060 hPa)
LYING SURFACE (BED) SPECIFICATION
Surface size 61 x 76 cm (24 x 29,9 in)
Mattress size 60 x 75 x 2 cm (23,6 x 29,5 x 0,8 in)
Mattress to head height 80 cm (31,5 in)
TEMPERATURE CONTROL MODES
Pre-warm mode 33.0°C (91.4°F)
Manual control temperature mode 0%-100%, in 5% increments
Surface control temperature range 30.0°C (86°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin control temperature range 32.0°C (89.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Mattress heating temperature range 30.0°C (86°F) to 33.0°C (91.4°F), in 1°C increments
Peripherial skin / Rectal temperature monitoring Yes
PERFORMANCE
Temperature rise time 25 °C (77°F) ambient < 30 min
Temperature variability under 0.5°C (0.9°F)
Temperature uniformity on the surface of the mattress under 0.7°C (1.2°F)
Correlation of the indicated air temperature with the actual surface temperature ≤ 0.7°C (1.2°F)
Display precision of skin temperature under ±0.1°C (0.1°F)
Measuring precision of skin temperature sensor under ±0.3°C (0.5°F)
APGAR warning signal after 1 / 5 / 10 min
OXYGEN SERVO CONTROL
Oxygen control range 21% to 90% (head hood)
Oxygen control accuracy of full scale ± 3%
Oxygen display accuracy (100% calibration) ± 3%
Oxygen display accuracy (21% calibration) ± 3%
Oxygen display resolution 1%
WEIGHING SCALE
Weight range 0 to 8 kg (17,1 lbs)
Weight display resolution 5 gr or 0,2 oz
Weight accuracy up to 5 kg ± 5 gr, over 5 kg ± 10 gr
Low voltage alarm
LOADING
Max. load of mattress 10 kg (22,1 lbs)
Max. load of IV pole 2 kg (4,7 lbs)
Max load of shelves 2 kg (4,7 lbs)
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IP20
Electric safety IEC 60601-1; IEC 60601-2-21
TREND PARAMETERS
3/24/170-hour trend Surface temperature, Skin temperature, Mattress temperature, Peripherial temperature, Oxygen concentration, Heater power
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
First Aid Box Aluminium Small contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Material Aluminium
Age Group Adult Walkers
Height 37 Inch
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
WeightN/AN/AN/AN/AN/AN/A