OPzV Tubular Gel Battery 60AH-3000AH

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-18
Brands:: Reeco Power

Description

Features:

  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation,
OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere,
even in remote environments with minimal supervision.

 

Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8)
F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)

Reviews

There are no reviews yet.

Be the first to review “OPzV Tubular Gel Battery 60AH-3000AH”

Your email address will not be published. Required fields are marked *

Quick Comparison

OPzV Tubular Gel Battery 60AH-3000AH removeHigh Frequency Rack Mount UPS 33RM Series removePortable Power Station PX Series 1000W removeLine Interactive UPS AP Series 1000VA-3000VA remove3 Phase Low Frequency Online UPS LF33 Series remove3 Phase Low Frequency Solar Inverter DX Series remove
NameOPzV Tubular Gel Battery 60AH-3000AH removeHigh Frequency Rack Mount UPS 33RM Series removePortable Power Station PX Series 1000W removeLine Interactive UPS AP Series 1000VA-3000VA remove3 Phase Low Frequency Online UPS LF33 Series remove3 Phase Low Frequency Solar Inverter DX Series remove
Image
SKUSF1033560130139-18SF1033560130139-12SF1033560130139-23SF1033560130139-16SF1033560130139-4SF1033560130139-5
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentFeatures:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Features:
  • True double-conversion
  • LCD screen auto-rotation with Rack position ( only for 10K-20K models)
  • DSP technology guarantees high performance
  • Output power factor 1
  • Support 1/1;3/1;3/3 Phase Adjustable
  • Active power factor correction in all phases
  • 50HZ / 60HZ frequency converter mode
  • ECO mode operation for energy saving ( ECO)
  • Emergency power off function ( EPO)
  • Generator compatible
  • Supports dual AC inputs
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers for long-run model
  • Supporting Parallel sharing of battery packs
  • Optional isolation transformer offers full isolation and complete common mode noise rejection
  • Support with SNMP,USB, RS232 communication
 
Technical Specifications
MODEL 33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
CAPACITY 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
PHASE 3 Phase input / 3 Phase output
PARALLEL CAPABILITY 4 Max
INPUT
Nominal Voltage 3×380 VAC (3Ph+N)
Voltage Range 190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load
Frequency Range 46-54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤1 % THD (Linear Load), ≤3% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Battery Type Depending on the applications
Numbers 20 pcs 32-40 pcs (Adjustable)
Charging Current (max.) 1A~ 12A (Adjustable) 1A~ 16A (Adjustable) 1A 〜18A (Adjustable)
Charging Voltage ±13.65 VDCx N (N=10) ±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm) 680*438*133 [3U] 797*438*176 [4U]
Net Weight (kgs) 27 30 40 45
ENVIRONMENT
Operation Temperture 0-40°C
Operation Humidity 0-95% and non-condersing
Noise Level Less than 62dB @ 1 Meter Less than 65dB @ 1 Meter Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Features:
  • Rated Power: 1000W
  • Rated Capacity: 932.4wh
  • Standard Capacity: 3.7V/252000mah
  • Overload Protecion: 1050+40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/150W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 8. 2kg
  • Weight(With Accessories): 10.2kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
 
Technical Specifications
 
MODEL UPS-AP1K ( L ) UPS-AP2K ( L ) UPS-AP3K ( L )
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50Hz-60Hz
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(batt.mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload 105%-110%: UPS beep alarm, do not shut down.
110%-130%: auto shut down after 30 seconds
> 130%: auto shut down immediately
Transfer time <typical 4ms
Waveform(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2 4 6
Charging current(Max.) Assume: 1A± 10%; Max: 1A or 2A for option
Charging voltage 27.3VDC±1% 54.7VDC±1% 82.0VDC±1%
Long-run model Battery type 12V, AH depending on applicant
Numbers 3 6 8
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1% 82.1VDC±1% 109.4VDC±1%
PHYSICAL
Standard model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 11.9 22 27.9
Long-run model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 8.5 16 18.2
ENVIRONMENT
Humidity 20-90%RH @0-40°C (non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP Management and web browser
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
 
Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare