Overhead stirrer PE-8300 (without stand rod)
$0.00
Shipped From Abroad
Purpose:
PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids
Advantages:
The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating.
Suitable for stirring:
– aqueous solution – 1 mPa/s
– liquid adhesive and fluid paint – 70-500 mPa/s
– many kinds of paint and enamel – 500-3000 mPa/s с
– color concentrate – 3000-30000 mPa/s
– thick glue (for parquet or linoleum) – 30000-50000 mPa/s
Technical specifications:
– Max. viscosity of fluid, mPa/s – 50000
– Volume of stirred sample, L – 0.25 – 20.0
– Rotation speed of stirrer shaft, rpm – 100 to 3000
– Max. rotational moment, Ncm – 60
– Max. stirrer shaft diameter, mm – 8(10)
– Max. stirrer shaft length – unlimited
– Rotational speed accuracy of stirrer, rpm – ±20 об./мин
– Max. power consumption, W – 100
– Supply voltage (50 Hz),V – 220 ± 10
– Dimensions of the unit (stand rod included), mm -100х190х255
– Weight, kg – 4.4
Scope of supply:
1. Overhead Stirrer – 1 pc
2. Propeller stirrer IM – 1 pc
Quick Comparison
Settings | Overhead stirrer PE-8300 (without stand rod) remove | Avalun 48 INR Microcuvette remove | Alcohol Pad Per Pack remove | Motic BA210 Series Biomedical Microscope remove | Avalun LabPad Device remove | Skyla Hi POC Clinical Chemistry Analyzer remove |
---|---|---|---|---|---|---|
Name | Overhead stirrer PE-8300 (without stand rod) remove | Avalun 48 INR Microcuvette remove | Alcohol Pad Per Pack remove | Motic BA210 Series Biomedical Microscope remove | Avalun LabPad Device remove | Skyla Hi POC Clinical Chemistry Analyzer remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560084-74 | SF1033560084-64 | SF1033560084-78 | SF1033560084-65 | SF1033560060-2 | |
Rating | ||||||
Price |
|
| $4.25 |
|
|
|
Stock | Out of stock | |||||
Availability | Out of stock | |||||
Add to cart | ||||||
Description | Shipped From Abroad
Purpose: PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Purpose: PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids Advantages: The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating. Suitable for stirring: - aqueous solution - 1 mPa/s - liquid adhesive and fluid paint - 70-500 mPa/s - many kinds of paint and enamel - 500-3000 mPa/s с - color concentrate - 3000-30000 mPa/s - thick glue (for parquet or linoleum) - 30000-50000 mPa/s Technical specifications: - Max. viscosity of fluid, mPa/s - 50000 - Volume of stirred sample, L - 0.25 – 20.0 - Rotation speed of stirrer shaft, rpm - 100 to 3000 - Max. rotational moment, Ncm - 60 - Max. stirrer shaft diameter, mm - 8(10) - Max. stirrer shaft length - unlimited - Rotational speed accuracy of stirrer, rpm - ±20 об./мин - Max. power consumption, W - 100 - Supply voltage (50 Hz),V - 220 ± 10 - Dimensions of the unit (stand rod included), mm -100х190х255 - Weight, kg – 4.4 Scope of supply: 1. Overhead Stirrer - 1 pc 2. Propeller stirrer IM - 1 pc | LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
| The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.