Overhead stirrer PE-8300 (without stand rod)

$0.00

Shipped From Abroad

Purpose:

PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Brands:: ECROSKHIM

Description

Purpose:

PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids

Advantages:

The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating.

Suitable for stirring:
– aqueous solution – 1 mPa/s

– liquid adhesive and fluid paint – 70-500 mPa/s
– many kinds of paint and enamel – 500-3000 mPa/s с
– color concentrate – 3000-30000 mPa/s
– thick glue (for parquet or linoleum) – 30000-50000 mPa/s

Technical specifications:
– Max. viscosity of fluid, mPa/s – 50000

– Volume of stirred sample, L – 0.25 – 20.0
– Rotation speed of stirrer shaft, rpm – 100 to 3000
– Max. rotational moment, Ncm – 60
– Max. stirrer shaft diameter, mm – 8(10)
– Max. stirrer shaft length – unlimited
– Rotational speed accuracy of stirrer, rpm – ±20 об./мин
– Max. power consumption, W – 100
– Supply voltage (50 Hz),V – 220 ± 10
– Dimensions of the unit (stand rod included), mm -100х190х255
– Weight, kg – 4.4

Scope of supply:
1. Overhead Stirrer – 1 pc

2. Propeller stirrer IM – 1 pc

Quick Comparison

SettingsOverhead stirrer PE-8300 (without stand rod) removeDiscover 5 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette removeDiscover 14 Panel Cup with Adulterants Per Pack removeiSED Fully Automated ESR Analyzer remove
NameOverhead stirrer PE-8300 (without stand rod) removeDiscover 5 Panel Cup with Adulterants Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette removeDiscover 14 Panel Cup with Adulterants Per Pack removeiSED Fully Automated ESR Analyzer remove
ImageDrug Test CupAvalun 48 INR MicrocuvetteDrug Test Cup
SKUSF1033560084-23SF1033560084-78SF1033560084-74SF1033560084-28SF1033560084-129
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart
DescriptionShipped From Abroad

Purpose:

PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids

Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose:

PE-8300 stirrer is intended for stirring a fluid of various viscosity, liquids and solid bodies, liquids and bulk solids

Advantages:

The Overhead Stirrer is fitted with built-in control unit with LCD, memorized settings function, motor protection against overload and overheating. Suitable for stirring: - aqueous solution - 1 mPa/s - liquid adhesive and fluid paint - 70-500 mPa/s - many kinds of paint and enamel - 500-3000 mPa/s с - color concentrate - 3000-30000 mPa/s - thick glue (for parquet or linoleum) - 30000-50000 mPa/s Technical specifications: - Max. viscosity of fluid, mPa/s - 50000 - Volume of stirred sample, L - 0.25 – 20.0 - Rotation speed of stirrer shaft, rpm - 100 to 3000 - Max. rotational moment, Ncm - 60 - Max. stirrer shaft diameter, mm - 8(10) - Max. stirrer shaft length - unlimited - Rotational speed accuracy of stirrer, rpm - ±20 об./мин - Max. power consumption, W - 100 - Supply voltage (50 Hz),V - 220 ± 10 - Dimensions of the unit (stand rod included), mm -100х190х255 - Weight, kg – 4.4 Scope of supply: 1. Overhead Stirrer - 1 pc 2. Propeller stirrer IM - 1 pc
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare