Pilot-RO Water Purification System

$0.00

Shipped From Abroad

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-2
Brands:: Hi-Tech

Description

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments

Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag

Reviews

There are no reviews yet.

Be the first to review “Pilot-RO Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPilot-RO Water Purification System removeDISSUB ANALYSER removePERSONAL CO2/O2 MONITOR-ASPIDA removeBistos BT- 720 Patient Monitor removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeOXYGEN & CARBON DIOXIDE MONITOR remove
NamePilot-RO Water Purification System removeDISSUB ANALYSER removePERSONAL CO2/O2 MONITOR-ASPIDA removeBistos BT- 720 Patient Monitor removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeOXYGEN & CARBON DIOXIDE MONITOR remove
ImageBistos BT-720 Patient Monitor
SKUSF1033560130126-2SF1033560130141-17SF1033560130141-11SF1033560059-8SF1033560130141-2SF1033560130141-12
Rating
Price

$0.00

$0.00

$0.00

$330.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • IP65 rated, ensuring the unit is dust tight and protected against water
  • Data logging capability
  • Man down alarm
  • Time Weighted Average (TWA) monitoring
  • Rechargeable batteries
  • Intelligent software – up to 2 users registered to one unit
  • User changeable alarms
  • We recommend: 23.5% for oxygen (O2) enrichment (As per NHS SOPS/EH40/OSHA); 19.5% for oxygen (O2) deficiency 0.5%; & 1.5% for carbon dioxide (CO2) enrichment
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad

The COSAMS unit was designed specifically for use on submarines, most directly those that operate on diesel engines. Built to exacting military standards for performance, reliability and endurance, the Analox COSAMS uses proprietary Gas Filter Correlation (GFC) technology to specifically analyze the unique properties of CO.

The COSAMS (Carbon Monoxide Submarine Atmosphere Monitoring System) has been designed for use on submerged submarines to support life, where crew can be living and working for up to 90 days. Carbon monoxide can be generated on a submarine in several ways, from cooking and fire, to the incomplete combustion of diesel fuel and chlorate candles.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentAn economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual

The Aspida is a robust, high specification personal oxygen (O2), carbon dioxide (CO2) or dual (O2 / CO2 combined) monitor which can be worn on a belt or even wall mounted as a backup to a primary safety system.

The Aspida, (Greek for Shield) helps you comply with the regulations, will remind you when maintenance is needed and it safeguards the user from the gas risks.  
Technical Specification
Aspida
Operating temperature -5°C to +50°C
Humidity Range 0 to 99% RH
Display High-visibility, Organic Light Emitting Diode (OLED) display
Alarm horn 95dB @ 30cm (110dB - man-down alarm)
LED indicators 1 x Green - OK, 1 x Amber - Fault, 1 x Red - Alarm
Internal data log 1 log every 30 seconds for at least 7 days of continuous use
Batteries 2 x NiMH 2100mAh AA batteries (or suitable AA type batteries)
Battery discharge time 15 hours under normal operation (passive atmospheric monitoring, minimal user interaction, no alarms)
Battery lifespan 2 years
Battery charge time 4.5 hours (from flat)
Charge power supply rating 9 V DC - 0.55A
Dimensions 127 x 44 x 90 mm / 5 x 1.7 x 3.5 inches (HxDxW)
Electronics warranty 2 years
IP rating IP65
Aspida Sensors
CO2 Sensor O2 Sensor
Sensor type Analox infrared MIR Electrochemical
Range 0.01 to 5% 0.1 to 25%
Accuracy (at standard temperature and pressure) ±2% of full scale between 0.01% and 2.5%, ±3% ±3% of full scale between 0.1% and 25%
Response time T90 <60 seconds T90 <30 seconds
Sensor life span 5 years 2 year (expected)
Characteristics

Personal Protection

Enriched oxygen (O2) can cause a condition on the human body called hyperoxia, enriched CO2 is highly toxic, both are a threat to life and must be safeguarded against. If an inert gas such as nitrogen (N2), argon (Ar), helium (He) or liquid nitrogen (LN2) leaks then this will deplete the levels of oxygen (O2) in the surrounding area, creating a dangerous atmosphere. The Aspida can offer personal protection and alerts to all of these risks, offering you true peace of mind.  

Ideal Solution

Offering audible and visual alarms, data logging and a man down alarm for lone workers, it is an ideal solution to protect staff from the dangers of a leak of carbon dioxide (CO2), oxygen (O2) or inert gas. The Aspida is an affordable, easy to operate gas detection monitor and is perfect for ensuring safety in areas where the gas is piped, used or stored. It operates using rechargeable battery technology allowing it to run for more than 12 hours continuously between charges.
 
Click here to download User Manual
Click here to download Data Sheet
Download Aspida Software
Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Features:
  • 3" color touch screen
  • Standard Confirgurations: SpO2 and Pulse
  • Optioal NIBP and Masimo SpO2
  • Short/long trend graphic/trend table display
  • Audio and visual alarm, adjustable alarm limit
  • Automatic brightness adjustment
  • Accurate SpO2 reading during motion or low perfusion
  • Perfusion index data / bar graphic display
  • Pitch tone variation for pulse rate
  • Internal memory for data storage
  • SD card for easy software upgrade
  • Over 8 hours of operation with the re-chargeable li-ion battery
  • PC software for data review and analysis on a computer
  Technical Specifications:
Model BT-720
Display 4.3" Color LCD Touch Screen
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/- 2%
Neonate +/- 3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250
NIBP* (Optional) Method Automatic Oscillometric
Operation Mode Manual/Automatic/STAT
Parameter Systolic/Diastolic/Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range Adult 100-210
Pediatric 100-160
Neonate 10-90
Mean Range Adult 20-230
Pediatric 20-175
Neonate 20-100
SpO2 Masimo* (Optional) Masimo SpO2
Battery Type (Capacity) Li-ion (4400mAh)
Run time 8 Hours
Charging Time 8 Hours
Interface RJ45, SD Card Slot
Warranty 2 Years
 
Click Here To Download Catalogue
 
Key Features
  • Uses a GFC infra-red sensing technique ensuring the system is not sensitive to hydrogen or water vapor
  • Built-in auto-zero function ensures sensor stability
  • Real-time monitoring ensures rapid response to carbon monoxide (CO) issues as they occur
  • 90 days data-logging allows records to be stored and used should they ever be needed
  • Easy to maintain allowing you to be more self-sufficient whilst minimizing downtime
  • Designed specifically for the submarine environment so it is able to cope with the demands of the environment in terms of EMC, shock and temperature
 
Technical Specifications

Click here to download Data Sheet
Click here to download Manual
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar