Pocket Conductivity Meter

$0.00

Shipped From Abroad

Model : CON-P

This all-in-one pocket conductivity meter offers unparalleled convenience and efficiency for a wide range of water quality monitoring applications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-113
Brands:: Scitek

Description

Pocket Conductivity Meter Features:
  1. The pocket conductivity meter can measure conductivity, TDS, salinity, resistivity and temperature altogether.
  2. Easy Auto. Calibration with standard solution recognition; Auto Temp. Compensation (ATC) which ensures accuracy in variant temperatures (0-50.0°C).
  3. Data hold function available.
  4. Different LCD display backlight color for easy operation.
  5. Complete kit with ready-to-use accessories, very easy to use in the field test.
  6. Restore to factory default function: available.
  7. Probe Replaceable, high cost-performance.
  8. IP rating: IP67.

 

Pocket Conductivity Meter Specifications:
Model CON-P
Conductivity Range 0 to 199.9μS/cm, 200 to 1999μS/cm, 2.0 to 20.00mS/cm
Resolution 0.1/1μS/cm, 0.01 mS/cm
Accuracy ±1.0% F.S ± 1 digit
Calibration Points 1 point
TDS Range 0.1 ppm to 10.00 ppt
TDS Factor 0.40 to 1.00
Salinity Range 0-10ppt
Resistivity Range 50Ω·cm to 20MΩ·cm
Temperature Range 0 to 50˚C (32-122˚F)
Accuracy ±0.2˚C
Packing Including 1. Meter (Probe and 4×1.5V AAA alkaline batteries preinstalled)
2. Standard Cond solution: 30mL: 1413μS/12.88mS/cm one for each
3. Sample Vials: 2pcs
4. Lanyard: 1pc
5. Hard carrying case: 1pc
Shipping Size (WxDxH)(mm) 280x330x130
N.W. / G.W. (kg) 1

Reviews

There are no reviews yet.

Be the first to review “Pocket Conductivity Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

Pocket Conductivity Meter removeEppendorf Pipette Tip 20ul Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer removeHawksley 1400 Haematocrit Centrifuge removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
NamePocket Conductivity Meter removeEppendorf Pipette Tip 20ul Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer removeHawksley 1400 Haematocrit Centrifuge removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
ImageEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560130127-113SF1033560084-136SF1033560084-125SF1033560084-118SF1033560084-129SF1033560084-6
Rating
Price

$0.00

$0.00

$1,320.00

$690.00

$0.00

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : CON-P This all-in-one pocket conductivity meter offers unparalleled convenience and efficiency for a wide range of water quality monitoring applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Pocket Conductivity Meter Features:
  1. The pocket conductivity meter can measure conductivity, TDS, salinity, resistivity and temperature altogether.
  2. Easy Auto. Calibration with standard solution recognition; Auto Temp. Compensation (ATC) which ensures accuracy in variant temperatures (0-50.0°C).
  3. Data hold function available.
  4. Different LCD display backlight color for easy operation.
  5. Complete kit with ready-to-use accessories, very easy to use in the field test.
  6. Restore to factory default function: available.
  7. Probe Replaceable, high cost-performance.
  8. IP rating: IP67.
 
Pocket Conductivity Meter Specifications:
Model CON-P
Conductivity Range 0 to 199.9μS/cm, 200 to 1999μS/cm, 2.0 to 20.00mS/cm
Resolution 0.1/1μS/cm, 0.01 mS/cm
Accuracy ±1.0% F.S ± 1 digit
Calibration Points 1 point
TDS Range 0.1 ppm to 10.00 ppt
TDS Factor 0.40 to 1.00
Salinity Range 0-10ppt
Resistivity Range 50Ω·cm to 20MΩ·cm
Temperature Range 0 to 50˚C (32-122˚F)
Accuracy ±0.2˚C
Packing Including 1. Meter (Probe and 4×1.5V AAA alkaline batteries preinstalled)
2. Standard Cond solution: 30mL: 1413μS/12.88mS/cm one for each
3. Sample Vials: 2pcs
4. Lanyard: 1pc
5. Hard carrying case: 1pc
Shipping Size (WxDxH)(mm) 280x330x130
N.W. / G.W. (kg) 1
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare