Portable Multiparameter Water Quality Meter

$0.00

Shipped From Abroad

These multi-parameter water quality meters contain a varying number of measurement functions. You can choose the measurement functions according to your needs. A water quality meter can measure pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, and DO. Designed for water quality professionals, the multiparameter water quality meter is an advanced laboratory meter that takes the guesswork out of measurement.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-46
Brands:: Scitek

Description

Multiparameter Water Quality Meter Features:

 

  1. The probes are made of high-quality titanium alloy for accurate measurement, which is more sensitive and lasts longer.
  2. 1 to 5-point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Reliable Automatic Temperature Compensation (ATC) ensures accurate measurements in water sources of all temperatures.
  4. The water quality meter turns off automatically after a few minutes of inactivity to save batteries.
  5. Automatically saves the measurement results after completion, making it easy to view the data later.
  6. Ideal for aquariums, hydroponics, marine, aquaculture and any water source.
  7. Concentration units (ppm, mg/L, mol/L, mmol/L) and ionic media are selectable
  8. Salinity and atmospheric pressure compensation eliminates measurement errors.
  9. USB interface for easy data transfer
  10. Can save 500 sets of measurement data for easy comparison

 

Multiparameter Water Quality Meter Specifications:
Model MWQ-P900 MWQ-P901 MWQ-P902 MWQ-P903 MWQ-P904
pH Range -2.000-20.000pH –
Resolution 0001,0.01,0.1pH, selectable –
Accuracy 0.002pH –
Calibration Points 1 to 5 points –
pH Buffer Options USA, NIST, DIN, 2 custom buffers –
ORP Range ±1999.9mV –
Resolution 0.1, 1mV, selectable –
Accuracy ±0.2mV –
Calibration Points 1 point –
Ion Range 0.001~19999 (depending on the range of ISE) – – – –
Resolution 0.001, 0.01, 0.1, 1 – – – –
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) – – – –
Measurement Units ppm, mg/L, mol/L, mmol/L – – – –
Calibration Paints 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) – – – –
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm – 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0001,0.01,0.1,1 – 0001,0.01,0.1,1
Accuracy ±0.5% F.S. – ±0.5% F.S.
Calibration Paints 1 to 5 points – 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm – 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear(0.0-10.0%/°C ).pure water – Linear(0.0-10.0%/°C ).pure water
Reference Temperature 20/25°C – 20/25°C
Cell Constant K=0.1, 1, 10 or custom – K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt – 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 001,0.1,1 – 001,0.1,1
Accuracy ±1% F.S. – ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) – 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt – 0.00~42.00 psu, 0.00~80.00 ppt – 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. – ±1% F.S.
Resistivity Range 0.00~20.00MΩ – 0.00~20.00 MΩ – 0.00~20.00MΩ
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation – – 0.00~20.00 mg/L 0.00~20.00mg/L, 0.0~200.0% saturation
0.0~200.0% saturation
Resolution 001mg/L,0.1% – – 001mg/L, 0.1% 001mg/L,0.1%
Accuracy ±0.2mg/L, ±2.0% – – ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points – – 1 or 2 points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual – – 60.0~112.5 kPa/ 450~850 mmHg, manual 60.0~112.5 kPa/ 450~850 mmHg, manual
Salinity Correction 0.0~50.0g/L, manual – – 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements 3× 1.5V AA batteries or DC5V power adapter
Sizes(W×D×H)(mm) 170× 85×30
Shipping Size (W×D×H)(mm) 450x320x100
N.W./G.W. (kg) 0.3/2

Reviews

There are no reviews yet.

Be the first to review “Portable Multiparameter Water Quality Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

Portable Multiparameter Water Quality Meter removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer removeAutomatic Pipette removeHawksley 1400 Haematocrit Centrifuge removeDiscover 14 Panel Cup with Adulterants Per Pack remove
NamePortable Multiparameter Water Quality Meter removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer removeAutomatic Pipette removeHawksley 1400 Haematocrit Centrifuge removeDiscover 14 Panel Cup with Adulterants Per Pack remove
ImageAvalun 48 INR MicrocuvetteDrug Test Cup
SKUSF1033560130127-46SF1033560084-74SF1033560060-2SF1033560084-130SF1033560084-118SF1033560084-28
Rating
Price

$0.00

$0.00

$0.00

$0.00

$690.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad These multi-parameter water quality meters contain a varying number of measurement functions. You can choose the measurement functions according to your needs. A water quality meter can measure pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, and DO. Designed for water quality professionals, the multiparameter water quality meter is an advanced laboratory meter that takes the guesswork out of measurement.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Multiparameter Water Quality Meter Features:
 
  1. The probes are made of high-quality titanium alloy for accurate measurement, which is more sensitive and lasts longer.
  2. 1 to 5-point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Reliable Automatic Temperature Compensation (ATC) ensures accurate measurements in water sources of all temperatures.
  4. The water quality meter turns off automatically after a few minutes of inactivity to save batteries.
  5. Automatically saves the measurement results after completion, making it easy to view the data later.
  6. Ideal for aquariums, hydroponics, marine, aquaculture and any water source.
  7. Concentration units (ppm, mg/L, mol/L, mmol/L) and ionic media are selectable
  8. Salinity and atmospheric pressure compensation eliminates measurement errors.
  9. USB interface for easy data transfer
  10. Can save 500 sets of measurement data for easy comparison
 
Multiparameter Water Quality Meter Specifications:
Model MWQ-P900 MWQ-P901 MWQ-P902 MWQ-P903 MWQ-P904
pH Range -2.000-20.000pH –
Resolution 0001,0.01,0.1pH, selectable –
Accuracy 0.002pH –
Calibration Points 1 to 5 points –
pH Buffer Options USA, NIST, DIN, 2 custom buffers –
ORP Range ±1999.9mV –
Resolution 0.1, 1mV, selectable –
Accuracy ±0.2mV –
Calibration Points 1 point –
Ion Range 0.001~19999 (depending on the range of ISE) – – – –
Resolution 0.001, 0.01, 0.1, 1 – – – –
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) – – – –
Measurement Units ppm, mg/L, mol/L, mmol/L – – – –
Calibration Paints 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) – – – –
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm – 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0001,0.01,0.1,1 – 0001,0.01,0.1,1
Accuracy ±0.5% F.S. – ±0.5% F.S.
Calibration Paints 1 to 5 points – 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm – 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear(0.0-10.0%/°C ).pure water – Linear(0.0-10.0%/°C ).pure water
Reference Temperature 20/25°C – 20/25°C
Cell Constant K=0.1, 1, 10 or custom – K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt – 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 001,0.1,1 – 001,0.1,1
Accuracy ±1% F.S. – ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) – 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt – 0.00~42.00 psu, 0.00~80.00 ppt – 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. – ±1% F.S.
Resistivity Range 0.00~20.00MΩ – 0.00~20.00 MΩ – 0.00~20.00MΩ
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation – – 0.00~20.00 mg/L 0.00~20.00mg/L, 0.0~200.0% saturation
0.0~200.0% saturation
Resolution 001mg/L,0.1% – – 001mg/L, 0.1% 001mg/L,0.1%
Accuracy ±0.2mg/L, ±2.0% – – ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points – – 1 or 2 points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual – – 60.0~112.5 kPa/ 450~850 mmHg, manual 60.0~112.5 kPa/ 450~850 mmHg, manual
Salinity Correction 0.0~50.0g/L, manual – – 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements 3× 1.5V AA batteries or DC5V power adapter
Sizes(W×D×H)(mm) 170× 85×30
Shipping Size (W×D×H)(mm) 450x320x100
N.W./G.W. (kg) 0.3/2
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8ËšC
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ËšC
Click Here To Download Catalogue
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare