Pour and Cloud Point Tester PE-7200I

Ask for Price$0.00

Shipped From Abroad

Purpose:
Determination of pour and cloud point points of motor fuels.
Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560105
Brands:: ECROSKHIM

Description

Purpose:
Determination of pour and cloud point points of motor fuels.
Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.
The equipment can be produced in 2 modifications:
Pour&Cloud Tester PE-7200A – the model has embedded computer
Pour&Cloud Tester PE-7200I – the possibility of information output on internal LCD display or connected PC.

Technical characteristics:
– Types of tested fuels- all brands motor fuel
– Accuracy of cloud point determination, °С – ±1.0
– Accuracy of pour point determination, °С – ±2.0
– Accuracy of temperature measurement, °С – 0.2
– Measurement time, min – up to 20
– Power supply, V- 220-250
– Power consumption, W, not more than – 300

Reviews

There are no reviews yet.

Be the first to review “Pour and Cloud Point Tester PE-7200I”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPour and Cloud Point Tester PE-7200I removeErma B-111 Bilirubin Meter removeLittle Sister Table Top Autoclave removeHawksley 1400 Haematocrit Centrifuge removeAvalun 48 INR Microcuvette removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NamePour and Cloud Point Tester PE-7200I removeErma B-111 Bilirubin Meter removeLittle Sister Table Top Autoclave removeHawksley 1400 Haematocrit Centrifuge removeAvalun 48 INR Microcuvette removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageAvalun 48 INR MicrocuvetteDrug Test Cup
SKUSF1033560105SF1033560084-6SF1033560084-46SF1033560084-118SF1033560084-74SF1033560084-23
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

$1,350.00

$690.00

Ask for Price$0.00

Ask for Price$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Purpose: Determination of pour and cloud point points of motor fuels. Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Purpose: Determination of pour and cloud point points of motor fuels. Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.
The equipment can be produced in 2 modifications: Pour&Cloud Tester PE-7200A – the model has embedded computer Pour&Cloud Tester PE-7200I - the possibility of information output on internal LCD display or connected PC.
Technical characteristics: - Types of tested fuels- all brands motor fuel - Accuracy of cloud point determination, °С – ±1.0 - Accuracy of pour point determination, °С – ±2.0 - Accuracy of temperature measurement, °С – 0.2 - Measurement time, min – up to 20 - Power supply, V- 220-250 - Power consumption, W, not more than - 300
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Features:
  • Indicator light indicates working state.
  • For 4~6 minutes rapidly sterilizing.
  • Sterilizing temperature and time can be preset.
  • Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
  • Over temperature & over pressure auto-protection.
  • Safe protection of water lacking.
  • Exhaust the cool air automatically.
  • With three stainless steel sterilizing plates.
  • The chamber of the sterilizer is made of stainless steel.
  • Automatically shut off with beep reminding after sterilization.
Technical Specifications:
   MODEL   MC-XB20J MC-XB24J

Sterilizing chamber volume

20L(φ250×420 mm) 24L(φ250×520 mm)
Maximum working pressure 0.22Mpa
Maximum working temperature 134℃
Adjustment of temperature 105-134℃
Timer 0-60 min
Chamber temperature equal ≤ ± 1℃
Source power 1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate 340×200×30 mm (3 piece) 400×200×30 mm (3 piece)
Dimension 480×480×384 mm 580×480×384 mm
Package dimension 700×580×500 mm 800×580×500 mm
 G. W/N.W 44/40 kg

50/45 kg

   
 
 
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare