Pour and Cloud Point Tester PE-7200I

$0.00

Shipped From Abroad

Purpose:
Determination of pour and cloud point points of motor fuels.
Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560105
Brand:
Brands:: ECROSKHIM

Description

Purpose:
Determination of pour and cloud point points of motor fuels.
Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.
The equipment can be produced in 2 modifications:
Pour&Cloud Tester PE-7200A – the model has embedded computer
Pour&Cloud Tester PE-7200I – the possibility of information output on internal LCD display or connected PC.

Technical characteristics:
– Types of tested fuels- all brands motor fuel
– Accuracy of cloud point determination, °С – ±1.0
– Accuracy of pour point determination, °С – ±2.0
– Accuracy of temperature measurement, °С – 0.2
– Measurement time, min – up to 20
– Power supply, V- 220-250
– Power consumption, W, not more than – 300

Reviews

There are no reviews yet.

Be the first to review “Pour and Cloud Point Tester PE-7200I”

Your email address will not be published. Required fields are marked *

Quick Comparison

Pour and Cloud Point Tester PE-7200I removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeEppendorf Minispin Centrifuge removeAvalun LabPad Device removeHawksley 1400 Haematocrit Centrifuge remove
NamePour and Cloud Point Tester PE-7200I removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeEppendorf Minispin Centrifuge removeAvalun LabPad Device removeHawksley 1400 Haematocrit Centrifuge remove
ImageAvalun Labpad machine
SKUSF1033560105SF1033560084-6SF1033560084-30SF1033560084-116SF1033560084-65SF1033560084-118
Rating
Price

$0.00

$715.00

$9.50

$0.00

$0.00

$690.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Purpose: Determination of pour and cloud point points of motor fuels. Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Purpose: Determination of pour and cloud point points of motor fuels. Pour&Cloud Point Tester for Petroleum Products PE-7200I is intended for determination of pour and cloud point points of motor fuels by express method. This new modification allows inserting probe directly that improves analysis accuracy. This equipment can be used for quick response quality control at refineries and also at acceptance test procedures. It essentially simplifies and cheapens the process of pour and cloud points measurement. The measurement procedure is fully automatic and continues not more than 20 minutes. It is important to notice that cooling mixture is not required. Here is used electronic refrigerator on Peltier element. Photometric sensor is constantly ensures the process of probe crystallization, thus excepting the possibility of error by laboratorian technician. Current information is indicated on the LCD display.
The equipment can be produced in 2 modifications: Pour&Cloud Tester PE-7200A – the model has embedded computer Pour&Cloud Tester PE-7200I - the possibility of information output on internal LCD display or connected PC.
Technical characteristics: - Types of tested fuels- all brands motor fuel - Accuracy of cloud point determination, °С – ±1.0 - Accuracy of pour point determination, °С – ±2.0 - Accuracy of temperature measurement, °С – 0.2 - Measurement time, min – up to 20 - Power supply, V- 220-250 - Power consumption, W, not more than - 300
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Twenty Five (25) Test Strip per PackPowerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar