Respiration Infection Gene Test POCT System
$0.00
Shipped From Abroad
A compact POCT system delivering fully automated sample‑to‑result analysis of 8 respiratory samples in ≤45 min, detecting up to 30 viral and bacterial pathogens via magnetic‑bead extraction and rapid multiplex RT‑PCR.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
A turnkey molecular diagnostic instrument for point‑of‑care settings, designed around an enclosed cartridge system. Users load the sample once and the device autonomously performs nucleic acid extraction via magnetic beads, multiplex real‑time PCR, and result reporting-without contamination or manual intervention. The built‑in touchscreen supports easy operation, data connectivity, and clear graphical outputs. Supports batch testing of eight samples, detecting up to 30 pathogens, including key viruses and bacteria, with rapid cycles and high precision.
Key Features
-
30-pathogen panel: Detects SARS-CoV-2, Influenza A/B, RSV A/B, parainfluenza (1–3), metapneumovirus, bocavirus, adenovirus B/C/E, Mycoplasma pneumoniae, coronavirus OC43/229E, and more
-
Fast turnaround: Processes 8 samples per batch; one run completes in ≤ 45 min, full 30-target panel in ~120 min
-
High extraction efficiency: Magnetic-bead method yields up to 99% nucleic acid recovery
-
Fully enclosed cartridge: Prevents contamination; supports closed, automated sample-to-result workflow
-
Integrated platform: Combines nucleic acid extraction, RT‑PCR amplification, and analysis—no need for external lab equipment.
-
High-speed thermal control: Heats/cools at up to 12 °C/s; temperature accuracy ±0.1 °C, uniformity ≤0.3 °C.
-
Multiplex fluorescence: 4 standard channels (FAM/HEX/ROX/CY5), expandable to 6 for additional flexibility.
-
Low noise & power: Runs quietly at 50 dB, draws 300 VA, supports broad voltage (AC 100–240 V)
Instrument Characteristics
-
Sample throughput: 8 simultaneously; single-tube detection of up to 30 pathogens halomedicals.com
-
Sample compatibility: Swabs, blood, serum, plasma, urine, tissues
-
Nucleic acid extraction: Magnetic‑bead, fully enclosed microfluidic channels; 100-400 µL sample volume
-
Temperature control: Uniform heating/cooling at 9-12 °C/s, control accuracy ±0.1 °C; duration accuracy ±3%
-
Fluorescence detection: 4‑channel (expandable to 6) for multiplex RT‑PCR
-
User experience: Touchscreen interface, graphical results, automated report generation, multiple data‑export options.
-
Contamination control: Closed cartridge design with microfluidic pollution barrier
-
Flexibility: Supports nesting protocols, single or multiplex testing; compatible with third-party reagents
-
Automation: Minimal manual steps-just sample load; device handles rest
-
Cost efficiency: Positioned at a lower price point compared to comparable international systems
Physical Specifications
-
Dimensions: 450 × 260 × 400 mm
-
Weight: 25 kg
-
Power supply: AC 100–240 V, 50/60 Hz, 3 A, 300 VA
-
Noise level: 50 dB during operation
Quick Comparison
Respiration Infection Gene Test POCT System remove | Plastic Urine Container Per Pack remove | Erma B-111 Bilirubin Meter remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Eppendorf Minispin Centrifuge remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Respiration Infection Gene Test POCT System remove | Plastic Urine Container Per Pack remove | Erma B-111 Bilirubin Meter remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Eppendorf Minispin Centrifuge remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | ||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||
SKU | SF1033560084-106 | SF1033560084-6 | SF1033560084-109 | SF1033560084-116 | SF1033560084-89 | |||||||||||
Rating | ||||||||||||||||
Price |
| $8.20 | $715.00 | $350.00 |
|
| ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
A compact POCT system delivering fully automated sample‑to‑result analysis of 8 respiratory samples in ≤45 min, detecting up to 30 viral and bacterial pathogens via magnetic‑bead extraction and rapid multiplex RT‑PCR.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||
Content | A turnkey molecular diagnostic instrument for point‑of‑care settings, designed around an enclosed cartridge system. Users load the sample once and the device autonomously performs nucleic acid extraction via magnetic beads, multiplex real‑time PCR, and result reporting-without contamination or manual intervention. The built‑in touchscreen supports easy operation, data connectivity, and clear graphical outputs. Supports batch testing of eight samples, detecting up to 30 pathogens, including key viruses and bacteria, with rapid cycles and high precision. Key Features
Instrument Characteristics
Physical Specifications
|
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| Features:
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system.
Features:
• Good accuracy owning to superior CMOS sensor & our own Algorism
• 10,000 test results data storage
• Instrument Check by Reference Kit
• Remote Support available (when connected via Internet)
• Built-in Thermal Printer and Barcode Scanner
• Data export to USB(PDF, Excel), Email and LIS
• Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃
• Shelf Life of Test Cassette & Buffer : 24 months
Click Here To Download Catalogue | ||||||||||