New

ri-scope® retinoscope

$0.00

Shipped From Abroad

The ri-scope® retinoscope, also referred to as the skiascope, measures the refractive power of the eye. Refractive flaws, such as near- and far-sightedness, as well as astigmatism, can be detected and diagnosed. Riester offers the split-light retinoscope (glow is a stitch) model.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

This retinoscope simplifies the diagnosis of astigmatic refractive flaws using a slit-light beam. The line image can be focused and precisely turned 360° using a knurled thumb screw, with the angle displayed on an integrated scale. It includes two fixation cards for dynamic retinoscopy, features an integrated eyeglass protection, and has a dust-proof casing made of impact-resistant ABS plastic.

Features and benefits
  • Available with XL 3.5 V xenon lamp or HL 2.5 V halogen lamp
  • The slit-light retinoscope, with a light beam in the form of a line, simplifies the detection and diagnosis of astigmatic refractive flaws. The reflex in the form of a line is moved vertically to the axis across the pupils of the patient with a slight oscillating movement. A shadow moves in the same or opposite direction.
    • Co-movement (plus lines): The patient is farsighted.
    • Counter-movement (minus lines): The patient is near-sighted.
  • Easy to operate with a knurled thumb screw. The line and spot image can be focused with the controls and turned 360°, with the angle read-out displayed on the integrated scale.
  • A holder for hanging and placement of the fixation card into position for dynamic retinoscopy.
  • Delivered with two fixation cards. The patient’s eye can adjust optimally to the distance to the retinoscope.
  • Integrated eyeglass protection
  • Bayonet fitting for quick and secure attachment to the handle
  • Dust-proof, very sturdy and light casing made of impact-resistant ABS plastic

 

Specifications
ri-scope® retinoscope
Dimension rethinoscope Dimension 
The lamp for ri-scope® retinoscope Slit – HL 2.5 V, 440 mA, mean life span 15 h
Slit – XL 3.5 V, 690 mA, mean life span 50 h
Battery 2 Alkaline AA / C 1.5 V batteries.
1 Li-Ion battery for C-handle
Ambient temperature 0 °C to 40 °C
Relative humidity 30% to 70% non-condensing
Storage/ Transport ambient temperature -10 °C to 55 °C
Storage/ Transport relative humidity 30% to 85% non-condensing
Air pressure/ Transport relative humidity 800 hPa – 1100 hPa

 

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “ri-scope® retinoscope”

Your email address will not be published. Required fields are marked *

Quick Comparison

ri-scope® retinoscope removeTonometer removeManual lensmeter removePortable Keratometer removeDigital Chart Projector removePortable Rebound Tonometer remove
Nameri-scope® retinoscope removeTonometer removeManual lensmeter removePortable Keratometer removeDigital Chart Projector removePortable Rebound Tonometer remove
ImageMecan Tonometer YZ7AMecan Manual lensmeter NJC-4Mecan SW 100 Portable KeratometerMecan BL-2 Digital Chart ProjectorMecan SW-500 Portable Rebound Tonometer
SKUSF1033560107-9SF1033560107-22SF1033560107-16SF1033560107-25SF1033560107-17
Rating
Price

$0.00

$220.00

$0.00

$0.00

$0.00

$1,815.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The ri-scope® retinoscope, also referred to as the skiascope, measures the refractive power of the eye. Refractive flaws, such as near- and far-sightedness, as well as astigmatism, can be detected and diagnosed. Riester offers the split-light retinoscope (glow is a stitch) model.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Ship from abroad
  • Easy installation and maintenance: It is quite easy to replace light bulks, and unnecessary to adjust its focus and position.
  • Customer Programmable: Icons can be displayed in predefined sequence by programming.
  • Display Single Icon: Display single icon by multi-function mask plate.
  • Tilted Placement: Perfect image position can be obtained by adjusting the horizontal axis of projector.
  • Standards parts: Metal plate with polarized coating (410x 410mm)
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThis retinoscope simplifies the diagnosis of astigmatic refractive flaws using a slit-light beam. The line image can be focused and precisely turned 360° using a knurled thumb screw, with the angle displayed on an integrated scale. It includes two fixation cards for dynamic retinoscopy, features an integrated eyeglass protection, and has a dust-proof casing made of impact-resistant ABS plastic.
Features and benefits
  • Available with XL 3.5 V xenon lamp or HL 2.5 V halogen lamp
  • The slit-light retinoscope, with a light beam in the form of a line, simplifies the detection and diagnosis of astigmatic refractive flaws. The reflex in the form of a line is moved vertically to the axis across the pupils of the patient with a slight oscillating movement. A shadow moves in the same or opposite direction.
    • Co-movement (plus lines): The patient is farsighted.
    • Counter-movement (minus lines): The patient is near-sighted.
  • Easy to operate with a knurled thumb screw. The line and spot image can be focused with the controls and turned 360°, with the angle read-out displayed on the integrated scale.
  • A holder for hanging and placement of the fixation card into position for dynamic retinoscopy.
  • Delivered with two fixation cards. The patient’s eye can adjust optimally to the distance to the retinoscope.
  • Integrated eyeglass protection
  • Bayonet fitting for quick and secure attachment to the handle
  • Dust-proof, very sturdy and light casing made of impact-resistant ABS plastic
 
Specifications
ri-scope® retinoscope
Dimension rethinoscope Dimension 
The lamp for ri-scope® retinoscope Slit - HL 2.5 V, 440 mA, mean life span 15 h Slit - XL 3.5 V, 690 mA, mean life span 50 h
Battery 2 Alkaline AA / C 1.5 V batteries. 1 Li-Ion battery for C-handle
Ambient temperature 0 °C to 40 °C
Relative humidity 30% to 70% non-condensing
Storage/ Transport ambient temperature -10 °C to 55 °C
Storage/ Transport relative humidity 30% to 85% non-condensing
Air pressure/ Transport relative humidity 800 hPa - 1100 hPa
  Download Brochure
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
Digital Chart Projector-Features:
  • Easy installation and maintenance: It is quite easy to replace light bulks, and unnecessary to adjust its focus and position.
  • Customer Programmable: Icons can be displayed in predefined sequence by programming.
  • Display Single Icon: Display single icon by multi-function mask plate.
  • Tilted Placement: Perfect image position can be obtained by adjusting the horizontal axis of projector.
  • Standards parts: Metal plate with polarized coating (410x 410mm)
Technical Specifications of Digital Chart Projector:
Projection Distance
1.5m~6m
Projection Magnification
30x (at 5m)
Projection Size
330x270mm (at 5 m)
Chart Switching Speed
One chart per 0.03s
Mask Switching Speed
1 open, 5 horizontal different lines, 8 vertical lines, 21 single letters, 1 red/green
Program
2 sets programs, each program contains up to 30 steps
Speed of mask conversion
One mask per 0.03s
Lamp
LED lamp
Auto-off function
After 10 minutes idle time
Power Source
AC 220V, 50Hz or 110V, 60Hz
Power consumption
40W
Accessories
Remote control, polarized metal screen, halogen lamp, polarized glasses, fuses (2), batteries (2)
 
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare