ri-scope® retinoscope
$0.00
Shipped From Abroad
The ri-scope® retinoscope, also referred to as the skiascope, measures the refractive power of the eye. Refractive flaws, such as near- and far-sightedness, as well as astigmatism, can be detected and diagnosed. Riester offers the split-light retinoscope (glow is a stitch) model.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
This retinoscope simplifies the diagnosis of astigmatic refractive flaws using a slit-light beam. The line image can be focused and precisely turned 360° using a knurled thumb screw, with the angle displayed on an integrated scale. It includes two fixation cards for dynamic retinoscopy, features an integrated eyeglass protection, and has a dust-proof casing made of impact-resistant ABS plastic.
Features and benefits
- Available with XL 3.5 V xenon lamp or HL 2.5 V halogen lamp
- The slit-light retinoscope, with a light beam in the form of a line, simplifies the detection and diagnosis of astigmatic refractive flaws. The reflex in the form of a line is moved vertically to the axis across the pupils of the patient with a slight oscillating movement. A shadow moves in the same or opposite direction.
- Co-movement (plus lines): The patient is farsighted.
- Counter-movement (minus lines): The patient is near-sighted.
- Easy to operate with a knurled thumb screw. The line and spot image can be focused with the controls and turned 360°, with the angle read-out displayed on the integrated scale.
- A holder for hanging and placement of the fixation card into position for dynamic retinoscopy.
- Delivered with two fixation cards. The patient’s eye can adjust optimally to the distance to the retinoscope.
- Integrated eyeglass protection
- Bayonet fitting for quick and secure attachment to the handle
- Dust-proof, very sturdy and light casing made of impact-resistant ABS plastic
Specifications
| ri-scope® retinoscope | |
|---|---|
| Dimension | |
| The lamp for ri-scope® retinoscope | Slit – HL 2.5 V, 440 mA, mean life span 15 h Slit – XL 3.5 V, 690 mA, mean life span 50 h |
| Battery | 2 Alkaline AA / C 1.5 V batteries. 1 Li-Ion battery for C-handle |
| Ambient temperature | 0 °C to 40 °C |
| Relative humidity | 30% to 70% non-condensing |
| Storage/ Transport ambient temperature | -10 °C to 55 °C |
| Storage/ Transport relative humidity | 30% to 85% non-condensing |
| Air pressure/ Transport relative humidity | 800 hPa – 1100 hPa |
Quick Comparison
| ri-scope® retinoscope remove | Automatic Computer Goldmann (Visual Field Analyzer) remove | Manual lensmeter remove | Portable Fundus Camera remove | SW-1000 Ophthalmic Ultrasound Scanner-A-Scan remove | Digital Chart Projector remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | ri-scope® retinoscope remove | Automatic Computer Goldmann (Visual Field Analyzer) remove | Manual lensmeter remove | Portable Fundus Camera remove | SW-1000 Ophthalmic Ultrasound Scanner-A-Scan remove | Digital Chart Projector remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SKU | SF103356013013 | SF1033560107-22 | SF1033560107-23 | SF1033560107-27 | SF1033560107-25 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Price |
| $3,850.00 |
| $2,310.00 | $1,815.00 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
The ri-scope® retinoscope, also referred to as the skiascope, measures the refractive power of the eye. Refractive flaws, such as near- and far-sightedness, as well as astigmatism, can be detected and diagnosed. Riester offers the split-light retinoscope (glow is a stitch) model.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
Features:
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
| 83Shipped from abroad
This is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
| Shipped from abroad
| Ship from abroad
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Content | This retinoscope simplifies the diagnosis of astigmatic refractive flaws using a slit-light beam. The line image can be focused and precisely turned 360° using a knurled thumb screw, with the angle displayed on an integrated scale. It includes two fixation cards for dynamic retinoscopy, features an integrated eyeglass protection, and has a dust-proof casing made of impact-resistant ABS plastic.
Features and benefits
Specifications
| The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases.
Feature:
* Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.
* Personalized design,accurate clinical analysis,accurate and repid examination strategy.
* Under international Goldman standard,providing a variety of classic test procedures and report analysis.
Technical Specification:
Click Here To Download Catalogue | The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
| Portable Fundus Camera is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Features of Portable Fundus Camera:
| Feature:
| Digital Chart Projector-Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Additional information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||










Reviews
There are no reviews yet.