The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ with Acuity Testing on Side 1 and Continuous Text Reading on Side 2. Includes Jaeger and Snellen notations, pupil gauge, and rulers.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Ship from abroad
- Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
- Durable and easy to operate
- Easily and intuitively read the sphere focal scale value
- High eco-friendly materials
- Design fitting the face curve and no stimulation
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Digital Slit lamp system,Galilean optical system,Five magnifications.
- Independent image process and management software system
- More than 10 million pixel image resolution
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check archive
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | The Rosenbaum Pocket Vision Screening Card utilizing PV Numbers™ provides 20/800 distance equivalent testing when held at a distance of 16 inches (40 cm). This card fits easily in a pocket for quick, convenient visual acuity screening. This Pocket Eye Chart is printed on durable plastic, and includes matching 20/200 Jaeger notation. Side 1 also includes pupil diameter gauge.
Side 2 features continuous text format. This format helps to simulate everyday activities such as reading. This simulation leads to better testing of the patient and helps identify near vision problems that interfere with normal activities. Side 2 includes both metric and standard rulers. | The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Features:
- The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
- Quickly and precisely measure the astigmatism axis.
- The light can be converged, radiated, and paralleled.
- Automatic Power Off function effectively protects the bulb.
- Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance |
1 m |
Streak |
3 mm-20 mm |
Streak Rotation |
360° |
Illumination Source |
3V/2W, halogen bulb |
Input Voltage |
AC 220V±10%, 50Hz±1Hz |
Power Consumption |
4.5 VA |
| Features:
- Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
- Durable and easy to operate
- Easily and intuitively read the sphere focal scale value
- High eco-friendly materials
- Design fitting the face curve and no stimulation
- Easy to take and clean
- Free switch between the cross-cylindrical lens and the rotary prism
- When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
- It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere |
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1 |
Cylinder |
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1 |
Cylinder Axis |
Range: 0~180°, Step:5° |
Distance of Optical center (also known as Pupil) |
Range: 50~75mmStep: 1mm |
Sight Switch |
Range:∞~380mm (distance of Optical center is64mm) |
Front Chin Test |
Range: 0~16mm |
Distance (from cornea vertex to the lens surface) |
16mm |
Standard Accessories Lens |
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively |
Standard Accessories |
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover |
Auxiliary Lens |
“O”:Open aperture
“R”:Retinoscope lens
“R”:Retinoscope lens
“R”:Retinoscope lens
*Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters
“P”:Polaroid
* it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision
“RMV”:Red Vertical maddox
*Be used to examine Implicit strabismus
“RMH”:Red horizontal maddox
*Be used to examine Implicit strabismus
“WMV”:Plane Vertical Maddox
*Be used to examine Implicit strabismus
“WMH”:Plane horizontal maddox
*Be used to examine Implicit strabismus
“RL”:Red lens
*Be used to examine eye function, Blending function and Implicit strabismus
“GL”:Green lens
*Be used to examine eye function, Blending function and Implicit strabismus
“+”:Test mark of optical center adjustment
“+.12”:Dioptric of the Spherical Lens is +0.12m-1
*Be used for the semi-adjustment of sphere lens, 0.25m-1
“PH”:1mmPinhole lens
*Be used to exclude visual non-refractive errors of the tested eye
“6ΔU”:6ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“10ΔI”:10ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“±0.50”:Cross-cylindrical lens
*Be used to examine the corrected dioptric of the Presbyopia and spherical lens
“OC”:Black lens
|
size |
338(L)×99(W)×292(H)mm |
NW |
about 5kg |
| Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of: the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc.
Features:
- Measurement can go along both in standing and lying posture
- Wireless data printing
- Easy to learn, easy to use
- Lightweight and handy
- No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index: |
Measuring Range : |
3mmHg~70mmHg |
Measuring Error: |
±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg) |
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg) |
Environment Requirement: |
Transport and Storage: |
Ambient temperature:-20℃~+55℃ |
Relative moisture:≦95% |
Atmosphere pressure:500hPa~1060hPa |
Running: |
Ambient temperature:+5℃~+40℃ |
Relative moisture:≦80% |
Atmosphere pressure:700hPa~1060hPa |
Rating voltage: DC3V(2 AA Batteries) |
Rating input power:1VA |
| Slit Lamp with Workstation Features:
- Digital Slit lamp system, Galilean optical system, Five magnifications
- Independent image process and management software system
- More than 10 million pixel image resolution
Technical Specifications:
Microscope Type |
Galileo Parallel |
Digital System |
External Digital Slit Lamp with 10 Mega pixels |
Magnification Change Way |
Drum Five Magnifications |
Eyepiece Magnification |
12.5x |
Total Magnifications |
6x, 10x, 16x, 25x,40x |
Diopter Adjustment |
-5D ~+5D |
Slit Width |
0-14MM Continuous |
Slit Height |
1-14MM Continuous |
Slit Angle |
0°- 180° Adjustable |
Slit Inclination Angle |
5°,10°,15°, 20° |
Light Spot Diameter |
0.2mm, 2mm, 3mm, 5mm, 10mm, 14mm |
Filter |
Heat Absorption; Grey; Red free; Cobalt Blue |
Fixation |
Red LED |
Illumination Bulb |
12V/50W German OSRAM Halogen Tungsten Lamp |
| Feature:
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by a pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check the archive
Technical Specifications:
Model |
SW-1000 Ophthalmic A Scan Biometer |
A Scan |
A scan probe |
10MHz import small size probe, built-in luminotron |
Measuring range |
15mm-40mm |
Measurement precision |
±0. 05mm; with macula lutea trace function |
Measurement |
Anterior chamber depth, lens thickness, vitreous body length, total length and average |
Method of measurement |
immersion and contact |
Eye mode |
Phakic/ Aphakic/Dense/ various IOL |
IOL formula |
SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS |
Storage |
10 cases, 5 readings each case |
Output |
A scan waveform and IOL calculation sheet
|
|