New
/

RVS-100 Vital Signs Monitor

$0.00

Shipped From Abroad

RVS-100 is a versatile, intuitive touch screen vital signs monitor that measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe). The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics as well as office-based and long-term care settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

The RVS-100 Vital Signs Monitor

The device has ‘Monitor‘, ‘Spot Check‘, and ‘Triage‘ profile options, as well as a ‘Demo’ mode.

Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. ‘Demo’ mode demonstrates how each measurement mode works.1

Advantages of the RVS-100

The aim of the EWS is to improve patient outcomes by identifying at-risk patients who need urgent medical attention and intervening early to prevent clinical deterioration. This system involves the assignment of numeric values to several physiologic parameters (i.e., temperature, respiratory rate, Spo2). RVS-100 can be programmed with NEWS (National Early Warning Scores), MEWS (Modified Early Warning Scores), and also has 5 customisable profiles which can be set by the end-user if they have different parameter values.

 

Features and Benefits

Hardware

  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • Can be plugged into the mains or powered from the battery for 17 hours
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2: Riester or Nellcor

Software

  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.3
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese.
Technical Specifications
RVS-100
Power supply 100 – 240 V AC, 50/60 Hz
Battery Lithium-Ion battery,
rechargeable, 10.8 V DC, 6600 mAh.
Charging time to 100%: 6 hours
Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on
AUTO mode (15-minute interval)
Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange), Audible Speaker gives an audible alarm, QRS tone, Supports Pitch Tone, and multi-level volume. Alarm tones meet the requirements of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB, test distance is 1 meter from the tone
Ports 1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15 V/1.2 A
NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult
SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg
Paediatric
SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg
Neonate
SYS 30 – 135 mmHg, DIA 10 – 110 mmHg, MAP 20 – 125 mmHg
Cuff pressure range 0 – 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg
Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 – 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software)
Adult 297 ±3 mmHg, Pediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 – 300 mmHg
DIA 0 – 300 mmHg
MAP 0 – 300 mmHg

SpO2-Riester
Measurement range 0 – 100%
Resolution 1%
Accuracy ±2% (70 to 100%)
±3% (40% to 69%)
Unspecified (0% to 39%)
Alarm range 0 – 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate
Measurement range
20 – 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric)
70 – 100%: ±3% (neonate)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 8 sec, 16 sec
Pulse rate Measurement range 20 – 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 – 250 bpm: ±3 bpm
251 – 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric, non-motion conditions)
70 – 100%: ±3% (neonate, non-motion conditions)
70 – 100%: ±3% (motion conditions)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate Measurement range 25 – 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions)
±5 bpm (motion conditions)

 

Download Catalogue

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “RVS-100 Vital Signs Monitor”

Your email address will not be published. Required fields are marked *

Quick Comparison

RVS-100 Vital Signs Monitor removeAmbu Oval Silicone resuscitator (Ambu Bag) removeSpinal Epidural Pack removeBettermed BT666EPZ Multi-function Electric Delivery Bed removeMcKesson Sprague Rappaport Stethoscope removePortable Stainless Steel Autoclave Sterilizer remove
NameRVS-100 Vital Signs Monitor removeAmbu Oval Silicone resuscitator (Ambu Bag) removeSpinal Epidural Pack removeBettermed BT666EPZ Multi-function Electric Delivery Bed removeMcKesson Sprague Rappaport Stethoscope removePortable Stainless Steel Autoclave Sterilizer remove
Image
SKUSF1033560084-62SF1033560084-25SF1033560084-51SF1033560084-35SF1033560084-4
Rating
Price

$0.00

$27.00

$0.00

$2,024.00

$17.00

$216.00

Stock

In stock

AvailabilityIn stock
Add to cart

DescriptionShipped From Abroad RVS-100 is a versatile, intuitive touch screen vital signs monitor that measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe). The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics as well as office-based and long-term care settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Function:Backrest tilting From 0°to 75° ±5° Hi-lo function Reverse:14°±1° Trendelenburg:12°±1°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
The RVS-100 Vital Signs Monitor
The device has ‘Monitor‘, ‘Spot Check‘, and ‘Triage‘ profile options, as well as a ‘Demo’ mode. Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. ‘Demo’ mode demonstrates how each measurement mode works.1
Advantages of the RVS-100
The aim of the EWS is to improve patient outcomes by identifying at-risk patients who need urgent medical attention and intervening early to prevent clinical deterioration. This system involves the assignment of numeric values to several physiologic parameters (i.e., temperature, respiratory rate, Spo2). RVS-100 can be programmed with NEWS (National Early Warning Scores), MEWS (Modified Early Warning Scores), and also has 5 customisable profiles which can be set by the end-user if they have different parameter values.
 
Features and Benefits
Hardware
  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • Can be plugged into the mains or powered from the battery for 17 hours
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2: Riester or Nellcor
Software
  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.3
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese.
Technical Specifications
RVS-100
Power supply 100 - 240 V AC, 50/60 Hz
Battery Lithium-Ion battery, rechargeable, 10.8 V DC, 6600 mAh. Charging time to 100%: 6 hours Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15-minute interval) Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange), Audible Speaker gives an audible alarm, QRS tone, Supports Pitch Tone, and multi-level volume. Alarm tones meet the requirements of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB, test distance is 1 meter from the tone
Ports 1 x AC power inlet 1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 x USB ports 1 x Equipotential grounding point 1 x RJ11 connector for nurse call DC out port 15 V/1.2 A
NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult SYS 30 - 270 mmHg, DIA 10 - 220 mmHg, MAP 20 - 235 mmHg Paediatric SYS 30 - 235 mmHg, DIA 10 - 220 mmHg, MAP 20 - 225 mmHg Neonate SYS 30 - 135 mmHg, DIA 10 - 110 mmHg, MAP 20 - 125 mmHg
Cuff pressure range 0 - 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 - 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg Double overpressure protection (hardware and software) Adult 297 ±3 mmHg, Pediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 - 300 mmHg DIA 0 - 300 mmHg MAP 0 - 300 mmHg

SpO2-Riester
Measurement range 0 - 100%
Resolution 1%
Accuracy ±2% (70 to 100%) ±3% (40% to 69%) Unspecified (0% to 39%)
Alarm range 0 - 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate Measurement range 20 - 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric) 70 - 100%: ±3% (neonate) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 8 sec, 16 sec
Pulse rate Measurement range 20 - 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 - 250 bpm: ±3 bpm 251 - 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric, non-motion conditions) 70 - 100%: ±3% (neonate, non-motion conditions) 70 - 100%: ±3% (motion conditions) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 2 - 4 sec, 4 - 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate Measurement range 25 - 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions) ±5 bpm (motion conditions)
  Download Catalogue Download Brochure
The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Features
  • The Ambu Oval Silicone resuscitator has a special textured surface combined with the unique support strap to ensures that a comfortable and firm grip is guaranteed, allowing for effective ventilation over extended periods, without the problem of hand fatigue.
  • The Ambu Oval Silicone Resuscitators is made out of a view parts that can be disassembled easily. The Ambu Oval Silicone Resuscitator can easy be cleaned and autoclaved (except the oxygen reservoir) at a temperature of 134° Celsius.
  • The unique shape is small and easy to hold. The ergonomic, lightweight design of Ambu Oval Silicone Resuscitator is made for optimal user handling and support even during extended ventilations.
  • The resuscitators are semi-transparent allowing for a visual check of the patient’s condition. A pressure limitation valve is optional for the adult version and has been included into the design of the pediatric versions to ensure the safety of the patient*.

* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O.

It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
  • Max Load: 250KG(550lb) in movement
  • Material: steel electrostatic spraying
  • Function:Backrest tilting From 0°to 75° ±5°
  • Hi-lo function
  • Reverse:14°±1°
  • Trendelenburg:12°±1°
  • Handset
  • Abdomen auto-extension decompression
  • PU knee crutches
  • Adjustable hand grip
  • phenolic compact laminate (HPL) bed board
  • #304 stainless steel dirty bowl
  • Backrest angle indicator
  • Bumper wheels
  • Pedal remote control
  • Back-up battery
Accessories: 4pcs 5” Taiwan castor with central brake system, 1pair brake pedal, 2pcs PP side rails, 2pcs head and foot board,1 set MOTECK motor, 4pcs bumper wheels, 2pcs angle indicators, 1pc electric cable holder, 2pcs PU knee crutches, 2pcs hand grip, 1pc stainless steel dirty bowl, 1set high density foam mattress, 4pcs Dust cover. Click Here To Download Catalogue
McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips. Features
  • McKesson Dual-Head Scope – Black
  • Lightweight combination diaphragm/bell chestpiece for wide frequency response.
  • Proprietary diaphragm enhances acoustic response by 50% over traditional designs.
  • Non-chill bell ring and diaphragm rims.
  • Adjustable aluminum binaurals with PVC eartips.
  • 21 inch PVC tubing.
  • Weighs 4 oz.
  • Overall length 32-1/4 inches.
  • Not Made with Natural Rubber Latex.
 Technical Specification
  • Bell Size: 0 – 3/5 Inch Bell
  • Binaurals Material: Adjustable Aluminum Binaurals
  • Chestpiece Material: Aluminum Chestpiece
  • Diaphragm Diameter: 1-3/4 Inch Diaphragm
  • Ear Pieces Type: 1 Pair PVC Ear Tips , 1 Pair Black Mushroom Ear Tips
  • Head Type: Double-Sided Chestpiece
  • Number of Tubes: 1 – Tube
  • Tube Length: 22 Inch Tube
  • Tube Type: Single Lumen
  • Latex Free Indicator: Not Made with Natural Rubber Latex
Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare