New
/

RVS-200 Integrated Modular Wall Diagnostic Station

$0.00

Shipped From Abroad

RVS-200 is a versatile, integrated modular wall diagnostic station that, like the RVS-100, measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe) with the additional option to add ophthalmoscopes, otoscopes, and dermatoscopes. The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics, as well as office-based and long-term care settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

Integrated RVS-100 Vital Signs Monitor

 

Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. Demo mode demonstrates how each measurement mode works.

Hardware

Features and benefits
  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • It can be plugged into the mains or powered from the battery for 17 hours.
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2:
    • Riester
    • Nellcor
  • Centralised power supply supports up to 3 diagnostic handles, from a choice of Riester ri-scope® L and EliteVue instrument heads:
    • Otoscope
    • Ophthalmoscope
    • Retinoscope
    • Dermatoscope
    • Tongue Blade Holder
    • Nasal Speculum
    • Bent Arm Illuminators
  • Integrated specula dispenser for the otoscope and nasal specula with 5 tubes for 5 different sizes of specula, dispenses a new specula for each examination, and is easy to refill and disinfect.

 

Software

Features and benefits
  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese
Space requirement

Dimension of RVS-200

600mm = 23,622 inch, 309mm = 12,165 inch, 871mm = 34,291 inch, 100mm = 3,937 inch

Power supply 100 – 240 V AC, 50/60 Hz
Battery Lithium-Ion battery, rechargeable, 10.8 V DC, 6600 mAh. Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval), Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker, Gives audible alarm, QRS tone. Supports Pitch Tone and multi-level volume. Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone
Ports 1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15 V/1.2 A

NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg
Paediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg
Neonate SYS 30 – 135 mmHg, DIA 10 – 110 mmHg, MAP 20 – 125 mmHg
Cuff pressure range 0 – 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg
Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 – 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Paediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software).
Adult 297 ±3 mmHg, Paediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 – 300 mmHg
DIA 0 – 300 mmHg
MAP 0 – 300 mmHg

SpO2 – Riester
Measurement range 0 – 100%
Resolution 1%
Accuracy ±2% (70% to 100%)
±3% (40% to 69%)
Unspecified (0% to 39%)
Alarm range 0 – 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate
Measurement range
20 – 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric)
70 – 100%: ±3% (neonate)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 8 sec, 16 sec
Pulse rate
Measurement range
20 – 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 – 250 bpm: ±3 bpm
251 – 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric, non-motion conditions)
70 – 100%: ±3% (neonate, non-motion conditions)
70 – 100%: ±3% (motion conditions)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate
Measurement range
25 – 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions)
±5 bpm (motion conditions)

RPT-100 (Filac 3000) Predictive Thermometer
Oral (Quick Mode) non-fever temps: 3 – 5 seconds, fever temps: 8 – 10 seconds
Oral (Standard Mode) 6 – 10 seconds
Axillary Mode 8 – 12 seconds
Rectal Mode 10 – 14 seconds
Direct Mode (all sites) 60 – 120 seconds
Measurement accuracy 35.5 °C – 42 °C
Direct Mode (all sites): ±0.1 °C (±0.2 °F)
Standard Mode (all sites): ±0.1 °C (±0.2 °F)
Quick Mode (oral only): ±0.3 °C (±0.5 °F)

 

Reviews

There are no reviews yet.

Be the first to review “RVS-200 Integrated Modular Wall Diagnostic Station”

Your email address will not be published. Required fields are marked *

Quick Comparison

RVS-200 Integrated Modular Wall Diagnostic Station removeOxygen Regulator (Japan Technology) removeElectric Suction Machine removeFoyomed Nasal Oxygen Cannula removeLittman Stethoscope removeTimesco Orion Laryngoscope Set remove
NameRVS-200 Integrated Modular Wall Diagnostic Station removeOxygen Regulator (Japan Technology) removeElectric Suction Machine removeFoyomed Nasal Oxygen Cannula removeLittman Stethoscope removeTimesco Orion Laryngoscope Set remove
ImageLittman StethoscopeTimesco Orion Laryngoscope Set
SKUSF1033560084-48SF1033560084-16SF1033560084-24SF1033560084-5SF1033560084-53
Rating
Price

$0.00

$17.00

$152.00

$1.30

$13.20

$98.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad RVS-200 is a versatile, integrated modular wall diagnostic station that, like the RVS-100, measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe) with the additional option to add ophthalmoscopes, otoscopes, and dermatoscopes. The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics, as well as office-based and long-term care settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Full brass+chrome plated
  • Easy to read dual scal gauge with screw-on polycarbonate lens for durability.
  • Precision engineered pressure compensated design flowmeter for precise flow.
  • Flowmeter with easy to read tube and virtually unbreakable transparent polycarbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Power consumption: 120W Maximum negative pressure: ≥0.09 MPa Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Bottle volume: 2500 ml, 2 pcs

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

In Stock

Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen.  Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula.  The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supplies single-use sets as a ready to use a system containing one blade and one handle in a clear pouch.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Integrated RVS-100 Vital Signs Monitor
  Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. Demo mode demonstrates how each measurement mode works.

Hardware

Features and benefits
  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • It can be plugged into the mains or powered from the battery for 17 hours.
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2:
    • Riester
    • Nellcor
  • Centralised power supply supports up to 3 diagnostic handles, from a choice of Riester ri-scope® L and EliteVue instrument heads:
    • Otoscope
    • Ophthalmoscope
    • Retinoscope
    • Dermatoscope
    • Tongue Blade Holder
    • Nasal Speculum
    • Bent Arm Illuminators
  • Integrated specula dispenser for the otoscope and nasal specula with 5 tubes for 5 different sizes of specula, dispenses a new specula for each examination, and is easy to refill and disinfect.

 

Software

Features and benefits
  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese
Space requirement

Dimension of RVS-200

600mm = 23,622 inch, 309mm = 12,165 inch, 871mm = 34,291 inch, 100mm = 3,937 inch
Power supply 100 - 240 V AC, 50/60 Hz
Battery Lithium-Ion battery, rechargeable, 10.8 V DC, 6600 mAh. Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval), Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker, Gives audible alarm, QRS tone. Supports Pitch Tone and multi-level volume. Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone
Ports 1 x AC power inlet 1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 x USB ports 1 x Equipotential grounding point 1 x RJ11 connector for nurse call DC out port 15 V/1.2 A

NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult SYS 30 - 270 mmHg, DIA 10 - 220 mmHg, MAP 20 - 235 mmHg Paediatric SYS 30 - 235 mmHg, DIA 10 - 220 mmHg, MAP 20 - 225 mmHg Neonate SYS 30 - 135 mmHg, DIA 10 - 110 mmHg, MAP 20 - 125 mmHg
Cuff pressure range 0 - 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 - 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Paediatric 130 mmHg, Neonate 75 mmHg Double overpressure protection (hardware and software). Adult 297 ±3 mmHg, Paediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 - 300 mmHg DIA 0 - 300 mmHg MAP 0 - 300 mmHg

SpO2 – Riester
Measurement range 0 - 100%
Resolution 1%
Accuracy ±2% (70% to 100%) ±3% (40% to 69%) Unspecified (0% to 39%)
Alarm range 0 - 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate Measurement range 20 - 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric) 70 - 100%: ±3% (neonate) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 8 sec, 16 sec
Pulse rate Measurement range 20 - 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 - 250 bpm: ±3 bpm 251 - 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric, non-motion conditions) 70 - 100%: ±3% (neonate, non-motion conditions) 70 - 100%: ±3% (motion conditions) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 2 - 4 sec, 4 - 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate Measurement range 25 - 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions) ±5 bpm (motion conditions)

RPT-100 (Filac 3000) Predictive Thermometer
Oral (Quick Mode) non-fever temps: 3 - 5 seconds, fever temps: 8 - 10 seconds
Oral (Standard Mode) 6 - 10 seconds
Axillary Mode 8 - 12 seconds
Rectal Mode 10 - 14 seconds
Direct Mode (all sites) 60 - 120 seconds
Measurement accuracy 35.5 °C - 42 °C Direct Mode (all sites): ±0.1 °C (±0.2 °F) Standard Mode (all sites): ±0.1 °C (±0.2 °F) Quick Mode (oral only): ±0.3 °C (±0.5 °F)
 
  • Full brass+chrome plated
  • Easy to read dual scale gauge with screw-on poly carbonate lens for durability.
  • Precision engineered pressure compensated design flow meter for precise flow.
  • Flow meter with easy to read tube and virtually unbreakable transparent poly carbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
         
 
 
Specification : Voltage: AC 220V, 50Hz or 110V, 60Hz Power consumption: 120 W Maximum negative pressure: ≥0.09 MPa Negative pressure range: 0.02 MPa to Max negative pressure Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Rest Time≥30min Bottle volume: 2500 ml, 2 pcs Accessory: pedal switch (1pc), power switch(1pc), filter(2 pcs), suction pipe(1pc, 2m in length, silica gel), celiac suction pipe(1pc, 31cm in length, chrome copper) Package: 1pc/carton Box Size : 46.5*41.5*64.5cm Net Weight: 11.5KGS Gross Weight:13.8 KGS
Click Here To Download Catalogue
Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen.  Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula.  The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Features:
  • Material: clear, non-toxic PVC.
  • A single-use, disposable nasal cannula.
  • A highly flexible and lightweight piece with two prongs.
  • Comes in an over-the-ear design to ensure premium comfort.
  • Available with an anti-crush, 7 ft tubing.
  • Different types of prongs are available.
  • A must-have medical equipment for hospitals and more.
Littman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supply single use sets as a ready to use system containing one blade and one handle in a clear pouch.
  • A clear, impact resistant polypropylene case, which allows the contents to be clearly visible.
  • Designed to hold Macintosh 2, 3 and 4 blades and a laryngoscope handle.
  • There is a unique flexible button on the lid to allow EES engines and handles to be tested without opening the case.
  • Contains BioCote silver phosphate glass antimicrobial technology to preserve the surface and prevent degradation caused by microbial growth.
  • Set consists of Orion handle, Orion Mac 4, 3 & 2 blades
  • CE marked
  • Latex free
  • Extensive guarantees
  • ISO 7376 compatible
  • Supplied with multilingual instructions
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare