New
/

RVS-200 Integrated Modular Wall Diagnostic Station

$0.00

Shipped From Abroad

RVS-200 is a versatile, integrated modular wall diagnostic station that, like the RVS-100, measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe) with the additional option to add ophthalmoscopes, otoscopes, and dermatoscopes. The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics, as well as office-based and long-term care settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

Integrated RVS-100 Vital Signs Monitor

 

Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. Demo mode demonstrates how each measurement mode works.

Hardware

Features and benefits
  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • It can be plugged into the mains or powered from the battery for 17 hours.
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2:
    • Riester
    • Nellcor
  • Centralised power supply supports up to 3 diagnostic handles, from a choice of Riester ri-scope® L and EliteVue instrument heads:
    • Otoscope
    • Ophthalmoscope
    • Retinoscope
    • Dermatoscope
    • Tongue Blade Holder
    • Nasal Speculum
    • Bent Arm Illuminators
  • Integrated specula dispenser for the otoscope and nasal specula with 5 tubes for 5 different sizes of specula, dispenses a new specula for each examination, and is easy to refill and disinfect.

 

Software

Features and benefits
  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese
Space requirement

Dimension of RVS-200

600mm = 23,622 inch, 309mm = 12,165 inch, 871mm = 34,291 inch, 100mm = 3,937 inch

Power supply 100 – 240 V AC, 50/60 Hz
Battery Lithium-Ion battery, rechargeable, 10.8 V DC, 6600 mAh. Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval), Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker, Gives audible alarm, QRS tone. Supports Pitch Tone and multi-level volume. Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone
Ports 1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15 V/1.2 A

NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg
Paediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg
Neonate SYS 30 – 135 mmHg, DIA 10 – 110 mmHg, MAP 20 – 125 mmHg
Cuff pressure range 0 – 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg
Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 – 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Paediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software).
Adult 297 ±3 mmHg, Paediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 – 300 mmHg
DIA 0 – 300 mmHg
MAP 0 – 300 mmHg

SpO2 – Riester
Measurement range 0 – 100%
Resolution 1%
Accuracy ±2% (70% to 100%)
±3% (40% to 69%)
Unspecified (0% to 39%)
Alarm range 0 – 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate
Measurement range
20 – 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric)
70 – 100%: ±3% (neonate)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 8 sec, 16 sec
Pulse rate
Measurement range
20 – 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 – 250 bpm: ±3 bpm
251 – 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 – 100%
Resolution 1%
Accuracy 70 – 100%: ±2% (adult, paediatric, non-motion conditions)
70 – 100%: ±3% (neonate, non-motion conditions)
70 – 100%: ±3% (motion conditions)
0 – 69%: unspecified
Alarm range 0 – 100%
Average time 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate
Measurement range
25 – 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions)
±5 bpm (motion conditions)

RPT-100 (Filac 3000) Predictive Thermometer
Oral (Quick Mode) non-fever temps: 3 – 5 seconds, fever temps: 8 – 10 seconds
Oral (Standard Mode) 6 – 10 seconds
Axillary Mode 8 – 12 seconds
Rectal Mode 10 – 14 seconds
Direct Mode (all sites) 60 – 120 seconds
Measurement accuracy 35.5 °C – 42 °C
Direct Mode (all sites): ±0.1 °C (±0.2 °F)
Standard Mode (all sites): ±0.1 °C (±0.2 °F)
Quick Mode (oral only): ±0.3 °C (±0.5 °F)

 

Reviews

There are no reviews yet.

Be the first to review “RVS-200 Integrated Modular Wall Diagnostic Station”

Your email address will not be published. Required fields are marked *

Quick Comparison

RVS-200 Integrated Modular Wall Diagnostic Station removeMcKesson Sprague Rappaport Stethoscope removeResmed AirSense10 CPAP Machine removeElectric Suction Machine removeAmbu Oval Silicone resuscitator (Ambu Bag) removeTimesco Eclipse McCoy Laryngoscope Set remove
NameRVS-200 Integrated Modular Wall Diagnostic Station removeMcKesson Sprague Rappaport Stethoscope removeResmed AirSense10 CPAP Machine removeElectric Suction Machine removeAmbu Oval Silicone resuscitator (Ambu Bag) removeTimesco Eclipse McCoy Laryngoscope Set remove
ImageTimesco Eclipse McCoy Laryngoscope Set
SKUSF1033560084-35SF1033560084-1SF1033560084-16SF1033560084-62SF1033560084-54
Rating
Price

$0.00

$17.00

$0.00

$152.00

$27.00

$0.00

Stock

In stock

AvailabilityIn stock
Add to cart

DescriptionShipped From Abroad RVS-200 is a versatile, integrated modular wall diagnostic station that, like the RVS-100, measures pulse rate (PR), oxygen saturation (SpO2), non-invasive blood pressure (NIBP), and temperature (oral/axillary probe) with the additional option to add ophthalmoscopes, otoscopes, and dermatoscopes. The flexible, modular design offers many configurations and settings to suit the needs of hospitals and clinics, as well as office-based and long-term care settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The AirSense 10 AutoSet is a premium auto-adjusting therapy device. It features AutoRampâ„¢ with sleep onset detection, expiratory pressure relief (EPRâ„¢) and Easy-Breathe technology. The AirSense 10 AutoSet provides advanced event detection, including indications of central sleep apnoea and Cheyne-Stokes respiration.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Power consumption: 120W Maximum negative pressure: ≥0.09 MPa Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Bottle volume: 2500 ml, 2 pcs

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Integrated RVS-100 Vital Signs Monitor
  Continuous Monitoring is designed for monitoring patients over time and includes physiological and technical alarms. Spot Check is designed for taking a single set of vital signs measurements on a patient. Patient information can be entered and managed, and while technical alarms are still available, physiological alarms are disabled. Triage is designed for rapidly taking vital signs measurements on many patients. Patient information is disabled, in addition to physiological alarms. Demo mode demonstrates how each measurement mode works.

Hardware

Features and benefits
  • Large 8“ full HD colour TFT-LCD screen displays large numbers and bright colour-coded parameters so that vital signs can be seen clearly and interpreted easily.
  • The screen is visible in both dark and lit rooms.
  • The touch screen and intuitive user interface make it quick and easy for patient information to be entered and settings amended as required.
  • The modular design is chosen by the customer around their needs, starting with the choice between a table/mobile stand or wall-mounted, through to the optional accessories like a printer.
  • It can be plugged into the mains or powered from the battery for 17 hours.
  • Riester is committed to providing reliable clinical measurements, including the choice of SpO2:
    • Riester
    • Nellcor
  • Centralised power supply supports up to 3 diagnostic handles, from a choice of Riester ri-scope® L and EliteVue instrument heads:
    • Otoscope
    • Ophthalmoscope
    • Retinoscope
    • Dermatoscope
    • Tongue Blade Holder
    • Nasal Speculum
    • Bent Arm Illuminators
  • Integrated specula dispenser for the otoscope and nasal specula with 5 tubes for 5 different sizes of specula, dispenses a new specula for each examination, and is easy to refill and disinfect.

 

Software

Features and benefits
  • RVS-100 is programmed with EWS: NEWS, MEWS, and 5 customisable profiles, which can be set by the end-user if they have bespoke requirements.
  • Serve a large patient population with the ability to save up to 1000 patient records, with up to 5000 measurements per patient.
  • Can be used on all patient types: adult, paediatric, and neonate.
  • RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR/EHR, according to the HL7 standard.
  • Software languages available: Chinese, Danish, English, French, German, Italian, Polish, Portuguese, Spanish (Europe), and Traditional Chinese
Space requirement

Dimension of RVS-200

600mm = 23,622 inch, 309mm = 12,165 inch, 871mm = 34,291 inch, 100mm = 3,937 inch
Power supply 100 - 240 V AC, 50/60 Hz
Battery Lithium-Ion battery, rechargeable, 10.8 V DC, 6600 mAh. Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25 °C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval), Low battery indicator, Charging battery indicator
Monitor dimensions 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)
Monitor weight 3600 g (7.94 lb) inc. temperature module, printer
Basket dimensions 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)
Alarm Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker, Gives audible alarm, QRS tone. Supports Pitch Tone and multi-level volume. Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone
Ports 1 x AC power inlet 1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 x USB ports 1 x Equipotential grounding point 1 x RJ11 connector for nurse call DC out port 15 V/1.2 A

NIBP (non-invasive blood pressure)
Measuring method Automatic oscillometric
Measurement range Adult SYS 30 - 270 mmHg, DIA 10 - 220 mmHg, MAP 20 - 235 mmHg Paediatric SYS 30 - 235 mmHg, DIA 10 - 220 mmHg, MAP 20 - 225 mmHg Neonate SYS 30 - 135 mmHg, DIA 10 - 110 mmHg, MAP 20 - 125 mmHg
Cuff pressure range 0 - 280 mmHg
Resolution 1 mmHg
Pressure accuracy Static ±3 mmHg Clinic ±5 mmHg, standard deviation ≤ 8 mmHg
Pulse rate range 40 - 240 bpm
Pulse rate accuracy 1 bpm
Initial inflation pressure Adult 160 mmHg, Paediatric 130 mmHg, Neonate 75 mmHg Double overpressure protection (hardware and software). Adult 297 ±3 mmHg, Paediatric 252 ±3 mmHg, Neonate 147 ±3 mmHg
Alarm range SYS 0 - 300 mmHg DIA 0 - 300 mmHg MAP 0 - 300 mmHg

SpO2 – Riester
Measurement range 0 - 100%
Resolution 1%
Accuracy ±2% (70% to 100%) ±3% (40% to 69%) Unspecified (0% to 39%)
Alarm range 0 - 100%
Average time 4 sec, 8 sec, 16 sec
Pulse rate Measurement range 20 - 250 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±1% or ±1 bpm which ever is greater

SpO2 – Nellcor
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric) 70 - 100%: ±3% (neonate) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 8 sec, 16 sec
Pulse rate Measurement range 20 - 300 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy 20 - 250 bpm: ±3 bpm 251 - 300 bpm: unspecified

SpO2 – Masimo
Measurement range 0 - 100%
Resolution 1%
Accuracy 70 - 100%: ±2% (adult, paediatric, non-motion conditions) 70 - 100%: ±3% (neonate, non-motion conditions) 70 - 100%: ±3% (motion conditions) 0 - 69%: unspecified
Alarm range 0 - 100%
Average time 2 - 4 sec, 4 - 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
Pulse rate Measurement range 25 - 240 bpm
Pulse rate Resolution 1 bpm
Pulse rate Accuracy ±3 bpm (non-motion conditions) ±5 bpm (motion conditions)

RPT-100 (Filac 3000) Predictive Thermometer
Oral (Quick Mode) non-fever temps: 3 - 5 seconds, fever temps: 8 - 10 seconds
Oral (Standard Mode) 6 - 10 seconds
Axillary Mode 8 - 12 seconds
Rectal Mode 10 - 14 seconds
Direct Mode (all sites) 60 - 120 seconds
Measurement accuracy 35.5 °C - 42 °C Direct Mode (all sites): ±0.1 °C (±0.2 °F) Standard Mode (all sites): ±0.1 °C (±0.2 °F) Quick Mode (oral only): ±0.3 °C (±0.5 °F)
 
McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips. Features
  • McKesson Dual-Head Scope – Black
  • Lightweight combination diaphragm/bell chestpiece for wide frequency response.
  • Proprietary diaphragm enhances acoustic response by 50% over traditional designs.
  • Non-chill bell ring and diaphragm rims.
  • Adjustable aluminum binaurals with PVC eartips.
  • 21 inch PVC tubing.
  • Weighs 4 oz.
  • Overall length 32-1/4 inches.
  • Not Made with Natural Rubber Latex.
 Technical Specification
  • Bell Size: 0 – 3/5 Inch Bell
  • Binaurals Material: Adjustable Aluminum Binaurals
  • Chestpiece Material: Aluminum Chestpiece
  • Diaphragm Diameter: 1-3/4 Inch Diaphragm
  • Ear Pieces Type: 1 Pair PVC Ear Tips , 1 Pair Black Mushroom Ear Tips
  • Head Type: Double-Sided Chestpiece
  • Number of Tubes: 1 – Tube
  • Tube Length: 22 Inch Tube
  • Tube Type: Single Lumen
  • Latex Free Indicator: Not Made with Natural Rubber Latex
The AirSense 10 AutoSet is a premium auto-adjusting therapy device. It features AutoRampâ„¢ with sleep onset detection, expiratory pressure relief (EPRâ„¢) and Easy-Breathe technology. The AirSense 10 AutoSet provides advanced event detection, including indications of central sleep apnoea and Cheyne-Stokes respiration. Optional pulse oximetry monitoring is also available. Modes include AutoSet and CPAP. With the wirelessly enabled AirSense 10 AutoSet patient trial devices you can stay more connected than ever before with your patients during their critical early days of adjusting to treatment. Feature
  • New AutoSet Response feature
ResMed’s AutoSet algorithm now allows for additional customisation of therapy with the new AutoSet Response feature which offers all the benefits of the enhanced AutoSet algorithm with gentler pressure increases for additional comfort.
  • Central apnoea and Cheyne-Stokes respiration detection
The AirSense 10 AutoSet differentiates between obstructive and central apnoeas and can also detect indications of Cheyne-Stokes respiration, so you can be confident that your patients are receiving appropriate therapy.
  • AutoRampâ„¢.
This new feature with sleep onset detection starts by delivering a low pressure for greater patient comfort. Then, once the patient falls asleep, it increases the pressure to the prescribed level.
  • Built-in ambient light sensor
Adjusts the brightness of the screen based on the light in the room. So if patients need to get up during the night, the screen’s back light won’t disrupt their bed partner.
  • Easy-Breathe motor
Is whisper-quiet, offering patients and their bed partners a more peaceful night’s sleep.
  • Expiratory pressure relief (EPR)
Maintains the optimal treatment for the patient during inhalation and reduces pressure during exhalation.
  • Consistent humidification
Throughout the night with the integrated HumidAirâ„¢ humidifier with advanced HumidAir technology helps patients adjust to treatment and use therapy longer. Technical Specification
  • Special User Features: AutoRamp, Intergrated Humidifier, Heated Hose Tube
  • Pressure Range: 4cm-20cm/h2O fixed pressure setting
  • Ramp Time: Auto adjusting ramp feature
  • Starting Ramp Pressure: AutoRamp starting at 4cm/H2O
  • Filters: Standard or Hypo-Allergenic Disposable
  • Device Set-up: Set according to RX or default mode
  • Data Storage Content: SD Card or Wireless Transmission (US Only) to Provider
  • Compliance Meter: On screed display
  • Humidifier: Integrated with Optional Heated Tubing
  • DC Power: 24V ---3.75A
  • AC Power: 100-240V, 50-60Hz
  • Actual Weight: 44 oz (2.75lbs)
  • Sound Level: 26.6 dBA with uncertainty of 2 dBA
Click Here To Download Catalogue
Specification : Voltage: AC 220V, 50Hz or 110V, 60Hz Power consumption: 120 W Maximum negative pressure: ≥0.09 MPa Negative pressure range: 0.02 MPa to Max negative pressure Pump rate: ≥20 L/min Noise: ≤60 dB Continuous Working Time: 0-30 min Rest Time≥30min Bottle volume: 2500 ml, 2 pcs Accessory: pedal switch (1pc), power switch(1pc), filter(2 pcs), suction pipe(1pc, 2m in length, silica gel), celiac suction pipe(1pc, 31cm in length, chrome copper) Package: 1pc/carton Box Size : 46.5*41.5*64.5cm Net Weight: 11.5KGS Gross Weight:13.8 KGS
Click Here To Download Catalogue
The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Features
  • The Ambu Oval Silicone resuscitator has a special textured surface combined with the unique support strap to ensures that a comfortable and firm grip is guaranteed, allowing for effective ventilation over extended periods, without the problem of hand fatigue.
  • The Ambu Oval Silicone Resuscitators is made out of a view parts that can be disassembled easily. The Ambu Oval Silicone Resuscitator can easy be cleaned and autoclaved (except the oxygen reservoir) at a temperature of 134° Celsius.
  • The unique shape is small and easy to hold. The ergonomic, lightweight design of Ambu Oval Silicone Resuscitator is made for optimal user handling and support even during extended ventilations.
  • The resuscitators are semi-transparent allowing for a visual check of the patient’s condition. A pressure limitation valve is optional for the adult version and has been included into the design of the pediatric versions to ensure the safety of the patient*.

* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O.

Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare