New

Schiötz Tonometer

$0.00

Shipped From Abroad

The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

Indispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.

Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks
0 to -1 graduation mark
One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa – 1060 hPa

 

Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Schiötz Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Schiötz Tonometer removePortable Rebound Tonometer removeView Tester (Manual Phoropter) removeOphthalmic AB Scan Machine removeRetinoscope removeSlit Lamp remove
NameSchiötz Tonometer removePortable Rebound Tonometer removeView Tester (Manual Phoropter) removeOphthalmic AB Scan Machine removeRetinoscope removeSlit Lamp remove
ImageMecan SW-500 Portable Rebound TonometerMecan VT-8 View Tester (Manual Phoropter)Mecan SW-2100 Ultrasound BiometryMecan YZ24 Streak RetinoscopeMecan SLM-JX Slit Lamp Serial
SKUSF1033560107-17SF1033560107-26SF1033560107-8SF1033560107-12SF1033560107-15
Rating
Price

$0.00

$1,815.00

$858.00

$4,895.00

$165.00

$1,375.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Ship from abroad
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentIndispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.
Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks 0 to -1 graduation mark One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa - 1060 hPa
  Download Catalogue
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
Features:
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
  • Easy to take and clean
  • Free switch between the cross-cylindrical lens and the rotary prism
  • When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
  • It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture “R”:Retinoscope lens “R”:Retinoscope lens “R”:Retinoscope lens *Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters “P”:Polaroid * it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision “RMV”:Red Vertical maddox *Be used to examine Implicit strabismus “RMH”:Red horizontal maddox *Be used to examine Implicit strabismus “WMV”:Plane Vertical Maddox *Be used to examine Implicit strabismus “WMH”:Plane horizontal maddox *Be used to examine Implicit strabismus “RL”:Red lens *Be used to examine eye function, Blending function and Implicit strabismus “GL”:Green lens *Be used to examine eye function, Blending function and Implicit strabismus “+”:Test mark of optical center adjustment “+.12”:Dioptric of the Spherical Lens is +0.12m-1 *Be used for the semi-adjustment of sphere lens, 0.25m-1 “PH”:1mmPinhole lens *Be used to exclude visual non-refractive errors of the tested eye “6ΔU”:6ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “10ΔI”:10ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “±0.50”:Cross-cylindrical lens *Be used to examine the corrected dioptric of the Presbyopia and spherical lens “OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
Functions of Ophthalmic AB Scan Machine:
  • Software image workstation
  • B, B+B, B+A, A modes
  • Video review for 100 images
  • PDF report output
  • Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan 1.Probe: 10MHz frequencies, with LED 2.Depth: 40mm 3.Precision: ±0.05mm 4.Eye mode: Phakic / Aphakic / Dense / Various IOL 5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average 6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat. 7.Calculation: Average and standard deviation 8.Store: 10 Scanning results for each eye
B scan 1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless 2.Scanning Mode: Sector Scanning 3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm 4.Geometric Location Precision: Lateral≤10%; Vertical≤5% 5.Depth: 60mm 6.Enhance the part of vitreous body and retina 7.Gain of probe:30dB-105dB 8.Scanning Angle : 53° 9.Gray Scale: 256 10.False Color: Multi colors OTC 11.Measure Mode: distances, perimeter and area 12.Movies: 100 images movie review,AVI ZIP JPG format image output 13.Output: PDF format case report, connect to normal printer
Others 1.Display Mode :B, B+B, B+A, A 2.Hint: preset keyword 3.Case Search: Multi-keywords 4.Working Platform: Windows XP, VISTA, WINDOWS7 5.User-defined report template
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection. Features:
  • The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
  • Quickly and precisely measure the astigmatism axis.
  • The light can be converged, radiated, and paralleled.
  • Automatic Power Off function effectively protects the bulb.
  • Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance 1 m
Streak 3 mm-20 mm
Streak Rotation 360°
Illumination Source 3V/2W, halogen bulb
Input Voltage AC 220V±10%, 50Hz±1Hz
Power Consumption 4.5 VA
Slit Lamp Features:
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type Galileo Parallel
Optics Super Optic System
Magnification Change Way Drum Rotation
Eyepiece Magnification 12.5x
Total Magnifications 6x 10x, 16x, 25x, 40x
Diopter Adjustment -5D ~+5D
Slit Width 0-14MM Continuous
Slit Height 1-14MM Continuous
Slit Angle 0°- 180° Adjustable
Light Source LED
Light Spot Diameter 0.2mm,  2mm, 3mm, 5mm, 10mm, 14mm
Filter Heat Absorption; Grey; Redfree; Cobalt Blue
Fixation Red LED
Electrical
Illumination Bulb LED
Input Voltage 110V/220V (±10%)
Applanation Tonometer Interface Included
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare