Spin Tissue Processor STP 120

$0.00

Shipped From Abroad

Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130128-3
Brand:
Brands:: Myr

Description

Features
  • A worldwide unique technique

Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.

  • ROTATIONAL AGITATION

The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.

  • SHAKING

This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.

  • CENTRIFUGING

This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel

The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.

  • Easy handling

The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.

  • Maximum safety standards for the user and the specimen

The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system.

In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process

If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.

Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg

Optional accessories

Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter

 

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Spin Tissue Processor STP 120”

Your email address will not be published. Required fields are marked *

Quick Comparison

Spin Tissue Processor STP 120 removeOPTIKA IM-3 Inverted Trinocular Phase Contrast Microscope removeOptika B-69 Binocular Microscope removeSyringe Needle Destroyer removeOPTIKA B-510-5 Trinocular Discussion Microscope removeOPTIKA B-383POL Trinocular Polarizing Microscope remove
NameSpin Tissue Processor STP 120 removeOPTIKA IM-3 Inverted Trinocular Phase Contrast Microscope removeOptika B-69 Binocular Microscope removeSyringe Needle Destroyer removeOPTIKA B-510-5 Trinocular Discussion Microscope removeOPTIKA B-383POL Trinocular Polarizing Microscope remove
ImageOPTIKA IM-3 Inverted Trinocular Phase Contrast MicroscopeOptika B-69 Binocular MicroscopeOPTIKA B-510-5 Trinocular Discussion MicroscopeOPTIKA B-383POL Trinocular Polarizing Microscope
SKUSF1033560130128-3SF1033560098-18SF1033560098-1SF1033560084-206SF1033560098-17SF1033560098-16
Rating
Price

$0.00

$0.00

$0.00

$157.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad IM Series has been engineered and designed to be your ideal solution for fast and reliable routine inspections. The glass stage surface allows optimal visual access to the objective turret. The straight neck leaves ample room for sample positioning and for the most advanced probes. A particularly simple and ingenious optical design allows stable alignments and smooth and accurate movements.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Ship from abroad Cordless, modern binocular microscope ideal for students and mainly primary schools with achromatic lenses (1000x), FN 18 eyepieces, finite optical system, coaxial focusing, StagErase™ eraseable mechanical stage, Abbe condenser and 1 W LED illumination with rechargeable batteries.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad OPTIKA B-510 Series represents the ideal, ultra-modern, advanced routine microscope for efficient analysis in transmitted light applications, carefully engineered considering all the relevant aspects for users.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad OPTIKA polarizing microscopes offer a complete system for your laboratory analysis, including polarizer and analyzer filters, Bertrand lens for conoscopic observation, compensator plates, and high-precision rotatable stages. Also available the X-LED illumination system, a high-intensity light source that delivers bright and clear images.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • A worldwide unique technique
Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.
  • ROTATIONAL AGITATION
The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.
  • SHAKING
This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.
  • CENTRIFUGING
This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel
The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.
  • Easy handling
The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.
  • Maximum safety standards for the user and the specimen
The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system. In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process
If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.
Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg
Optional accessories
Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter
 
Click here to download Catalogue
Specifications
Observation Modes Brightfield, phase contrast.
Head Trinocular observation head, inclined 45°. Diopter adjustment on left eyepiece. Interpupillary adjustment 50-75 mm.
Eyepieces Wide field eyepieces WF10x/22 with field number 22.
Objectives Infinity corrected optical system IOS (Infinity Optical System). Plan-achromatic LWD objectives infinity corrected, for thickness 1.2 mm, made by following objectives: IOS LWD W-PLAN PH 10x/0.25, W.D. 7.30 mm IOS LWD W-PLAN PH 20x/0.40, W.D. 6.86 mm IOS LWD W-PLAN PH 40x/0.65, W.D. 3 mm All objectives are treated with an anti-fungus treatment.
Stage Fixed stage, dimensions 250 x 160 mm. 2 stage insert (glass and metal) with a hole for small dimension specimens. OPTIONAL: Mechanical stage mountable on the right side of the stage, total dimension = 250 x 230 mm, X-Y translation range 120 x 80 mm, metallic interchangeable inserts for slides, Petri dishes, Terasaki, multi-Well plates, etc. Pair of side extensions to expand the surface of the stage.
Nosepiece Quintuple revolving nosepiece, rotation on ball bearings.
Focusing Coaxial coarse and fine focusing mechanism (graduated, 0.002mm) with upper stop, to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
Condenser LWD condenser, N.A. 0.30, working distance 72 mm. The condenser can be removed to extend the working distance up to 150 mm. Presented slider with phase rings 4x/10x and 20x/40x.
Illumination Light source type X-LED8 with white 8W LED; light intensity control using a knob on the front side of the frame. Color temperature: 6300K LED average lifetime approx. 50,000h Voltage: 110/240Vac, 50/60Hz, 1A; Fuse: T500mA 250V Max power required: 13W
Dimensions Height: 495 mm Width: 230 mm Width with optional mechanical stage: 300 mm Depth: 540 mm Weight: 9 kg
Accessories Blue, green and frosted filter. Instruction manual and dust cover included.
 
Click Here To Download Catalogue
Cordless, modern binocular microscope ideal for students and mainly primary schools with achromatic lenses (1000x), FN 18 eyepieces, finite optical system, coaxial focusing, StagErase™ eraseable mechanical stage, Abbe condenser and 1 W LED illumination with rechargeable batteries. Slim and easy to carry, it is equipped with arm/wrist rest support to reduce the fatigue during use and long lasting LED illumination to provide over 20 years of use. Features:
  • Observation mode: Brightfield.
  • Head: Binocular, 30° inclined; 360° rotating.
  • Dioptric adjustment: Left eyepiece.
  • Eyepiece: WF10x/18 mm, secured by screw
  • Nosepiece: Quadruple ball bearings revolving nosepiece, reversed.
  • Objectives: – Achromatic 4x/0.10, with anti-fungus treatment – Achromatic 10x/0.25, with anti-fungus treatment – Achromatic 40x/0.65, with anti-fungus treatment – Achromatic 100x/1.25 (oil), with anti-fungus treatment
  • Specimen stage: StagErase™ eraseable mechanical stage, 125×125 mm, 62×24 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Abbe N.A. 1.25, pre-centered, focusable, with iris diaphragm.
  • Illumination: 1 W LED, with brightness control, rechargeable batteries.
  • Color temperature: 6,300 K. Multi-plug 100-240Vac/5Vdc external power supply.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Binocular (Siedentopf)
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 55-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 18
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
Nosepiece Positions Quadruple
  Reversed Yes
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system 160
  Anti-fungus treatment Yes
  Parfocal distance (mm) 35
  Standard magnifications 40x-1000x
  Type Achromatic
  4x/0.10, W.D. 10.6 mm
  10x/0.25, W.D. 7.0 mm
  40x/0.65, W.D. 0.5 mm
  100x/1.25 (Oil), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 125x125
  Moving mechanism Rack and pinion
  Moving range (mm) 62x24
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Single Position Type Abbe
  Numerical aperture (N.A.) 1.25
  Diaphragms Iris
  Focusable By rotation
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 23
  Fine total travel (per single rotation) (mm) 1.2
  Fine graduations 100
  Fine resolution (µm) 12
  Upper stop to prevent contact Yes
Transmitted Illumination Type LED
  Light source power (W) 1
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 1.5
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 5 Vdc 500 mA
  Rechargeable batteries Yes
  Battery type Ni-MH (3x, AAA size)
  Working time of batteries (hours) 4
  Charging time of batteries (hours) 8
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  User Manual Digital version (downloadable)
Product Dimensions Height (mm) 330
  Width (mm) 135
  Depth (mm) 235
Product Weight (kg) 3.0
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Observation mode: Brightfield. Head: Trinocular (fixed photo port 50/50), 30° inclined, 360° rotating. Interpupillary distance: Adjustable between 50 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: Main head: WF10x/22 mm, high eye-point and with rubber cups. Additional head(s): WF10x/20 mm, high eye-point. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives (strain-free): – IOS W-PLAN 4x/0.10 – IOS W-PLAN 10x/0.25 – IOS W-PLAN 40x/0.65 – IOS W-PLAN 100x/1.25 (Oil) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Swing-out N.A. 0.2/0.9, with iris diaphragm, focusable and centerable. Transmitted illumination (Full Koehler type): X-LED3 with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
Specifications:
Optics
Image scale 4-100
Number of objectives 4
Lighting Transmitted light
Field curvature Plan
Colour correction achromatic
Suspension yes
Immersion lens yes
Condensor Abbe N.A.1.25
Lamp type LED (X-LED3, 3.6 W, comparable to a 50 W halogen bulb)
Objective 1 IOS W-PLAN 4x/0.10, W.D. 17.3 mm
Objective 2 IOS W-PLAN 10x/0.25, W.D. 10 mm
Objective 3 IOS W-PLAN 40x/0.65, W.D. 0.54 mm
Objective 4 IOS W-PLAN 100x/1.25, W.D. 0.13 mm, oil
Eyepiece WF 10x / 22 mm (Ø 30mm)
infinity corrected yes
Magnification 40-1000
Optical system infinity
Capacity
Brightness control yes
Fluorescence yes
brightfield yes
Mechanics
Type of build Trinocular
Viewing posture (°) 30° angled eyepiece
Specimen stage Cross table
Revolver 5
Focusing Coarse and fine movement
General
Weight (g) 9100
Height (mm) 420
Width (mm) 270
Length (mm) 390
Series B-510
Field of application
Biology and Medicine yes
 
Click Here To Download Catalogue
Observation mode: Brightfield, transmitted polarized light and conoscopy. Bertrand lens and polarizing attachment: Swing-out type with centering mechanism for observation in conoscopy/orthoscopy. Rotatable analyzer from 0° to 90° with graduated scale. Tint plates: 1° order red (λ); λ/4; Quartz wedge. Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating. Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. One with crosshair. Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings. Centering system for each objective. Objectives (strain-free): IOS N-PLAN POL 4x/0.10 IOS N-PLAN POL 10x/0.25 IOS N-PLAN POL 40x/0.65 IOS N-PLAN POL 60x/0.80 All with anti-fungus treatment. Specimen stage: Rotatable stage with locking mechanism. Vernier scale with accuracy 0.1 mm. Diameter 160 mm. Specimen slide clamps. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. With rotating polarizing filter. Transmitted illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6.300 K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
 Specifications
Head Trinocular, 30° inclined, 360° rotating.
Eyepiece WF10x/20mm and with cross-hair micrometer
Bertrand lens Swing-out type; center-able.
Polarizing attachment 0° – 90° rotating analyzing filter. Tint plates included: 1° order red (lambda), lambda/4, quartz wedge.
Nosepiece Quadruple, reversed
Objectives IOS N-PLAN POL 4x, 10x, 40x, 60x View Optika Objective Brochure
Focusing system Coaxial coarse and fine
Stage Round, 360° rotating, 160 mm diameter, with sample clips and stop knob
Condenser Abbe N.A. 1.25, iris diaphragm, focusable and centrable. With rotating polarizer
Illumination X-LED3 illumination system with brightness control. 3.6 Watt LED Luminous flux: 200 lumen Luminous intensity: 900 cd Equivalent to a dichroic halogen lamp with 20W, Equivalent to a standard halogen lamp with 50W Correlated Color Temperature: 6300K Pure white, no need of blue correction filter.
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare