The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560101-2
Brands:: Siare

Description

The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.

Features:

  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters:
    – O2 built-in Mixer device from 21% to 99%
    – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1
    – Inspiratory Flow
    – PEEP
    – Breathing Rate
    – Minute Volume;
    – Tidal Volume
    – Inspiratory Pressure Limit
    – Inspiratory Pause
    – Inspiratory Time
    – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.

Optional accessories

11054 AIRPAK 54 stand-alone medical air compressor
100150/IDF Isoflurane Vaporizer
100148/IDF Fluo-Halotane Vaporizer
100145/IDF Sevoflurane Vaporizer
100151/IDF Desflurane Vaporizer
A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto

 

Click Here To Download Catalogue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

Reviews

There are no reviews yet.

Be the first to review “Siare Morpheus M Anaesthetic Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSiare Morpheus M Anaesthetic Machine removeMedical Waste Incinerator (Capacity - 100Kg) removeFirst Aid Box Aluminium Large removeSyringe Needle Destroyer removeScrub Suit removeSiare Morpheus LT Anaesthetic Machine remove
NameSiare Morpheus M Anaesthetic Machine removeMedical Waste Incinerator (Capacity - 100Kg) removeFirst Aid Box Aluminium Large removeSyringe Needle Destroyer removeScrub Suit removeSiare Morpheus LT Anaesthetic Machine remove
Image
SKUSF1033560101-2SF1033560084-254SF1033560084-251SF1033560084-206SF1033560084-202SF1033560101- 3
Rating
Price

$0.00

$0.00

$69.50

$157.00

$11.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad The product is mainly suitable for solid medical waste (including pollution), waste plastic and rubber etc,at high temperatures they can be divided into organic compounds. We can offer all kinds of waste incinerator for industrial waste, medical waste, chemical waste and daily waste at any capacity.
Delivery & Availability: Typically 60 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it contains items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
LDF series waste incinerator adopt gasification combustion that can make garbage more sufficient burning. Waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries. Features:
  • Both gas-motivated and oil-motivated are all can be preferred according to customers' needs.
  • Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
  • Daily waste can be burned once by gasified incineration.
  • Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
  • Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.
Advantages:
  • Long lifetime
  • Totally enclosed operation
  • Suitable for treating infectious waste
  • Avoid secondary pollution
  • Simple operation
  • Smokeless and no harmful to environment
  • Continuously and fully burning
  • Simple operation
Incinerator LDF-100 Parameter:
Applicable hospital size 250 beds
Max. Burning Ability 100 kg/time
Size of the Burner 1.5m×1.15m×3m
Volume of the Burner Gasification room 0.5m3
second buming room 0.3m3
Chamber Temperature First chamber:600℃-700℃;
second chamber:300℃-1300℃
Ash residue ≤5%
Size of the filling entrance 620mm×800mm
Chimney Hight  10m,Out-radiusØ300
Blower 0.37kw
Auxiliary machine Power0.11kw,fuel consumption4-10kg/h
Re-burning machine Power0.11kw,fuel consumption6-10kg/h
Running voltage 220V or 380V
Weight About 4600(kg)
Flue&Gas Emission Standards:
OrdinalNumber Refuse name Measuring unit GB18484-2001
1 Blackness of Flue Ringelmann class 1
Gas
2 Smoke&Dust mg/m3 100
3 CO mg/m3 100
4 SO2 mg/m3 400
5 HF mg/m3 9.0
6 HCL mg/m3 100
7 NO2 mg/m3 500
Click Here To Download Catalogue
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
 
  • Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear, Ot Room Wear
  •  Color: Blue, Green, Magenta , Light Teal, Light Green, Sky blue, Ocean blue, Coral Pink
  •  Size: Small, Medium, Large, XL, XXL
  •  Gender: Male
  •  Material: Polycotton
  •  Sleeve Type: Half
  •  Pattern: Closed
  •  Disposable: No
  •  Neck Type: "V" Neck
  • Wash Care: Do Not Bleach, Machine Wash, Hand Wash
 
The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. LUNG VENTILATOR The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02. Operative Modes: MAN VC-VC PCV-APCV APCV P -SIMV V- SIMV Measured parameters: PAW RATE VM - VTE T INSP Fi02 MANUAL VENTILATION SYSTEM The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system. BREATHING SYSTEM The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare