Sidestream ETCO2 Sensor LH810

$0.00

Shipped From Abroad

LH810 is an economic cost sidestream end-tidal CO2 sensor, with built-in air pump extract ETCO2 and analyze, accurate and durable, Suitable for intubated and nasal tube patients, and more flexible in application environments. Compatible with muiti patient monitor brands.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Prior-care

Description

Features of Sidestream ETCO2 Sensor LH810

Suitable for intubated and non-intubated patients.

Plug and play, long service life

No calibration required

Barometer pressure: CO2, N2O, HE compensation for accurate measurement

Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2

Checking and confirming ET tube placement

Detecting ventilator airway connection

Fully compatible with Respironics module’s protocol

 

Specifications of Sidestream ETCO2 Sensor LH810
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading,
41-70mmHg @ ±5% of reading,
71-100mmHg @ ±8% of reading,
101-150mmHg @ ±10% of reading.
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH

 

Compatible Brands:
 

 

Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo

Reviews

There are no reviews yet.

Be the first to review “Sidestream ETCO2 Sensor LH810”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSidestream ETCO2 Sensor LH810 removeMediPlus Bain Circuit (Adult) removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeRender SD-M2000C+ Anesthetic Machine removeAgary I.V. Cannula removeOxygen Concentrator 3Ltr. remove
NameSidestream ETCO2 Sensor LH810 removeMediPlus Bain Circuit (Adult) removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeRender SD-M2000C+ Anesthetic Machine removeAgary I.V. Cannula removeOxygen Concentrator 3Ltr. remove
Image
SKUSF1033560084-21SF1033560096-4SF1033560011-11SF1033560084-221SF1033560084-40
Rating
Price

$0.00

$28.00

$0.00

$4,070.00

$7.10

$273.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

LH810 is an economic cost sidestream end-tidal CO2 sensor, with built-in air pump extract ETCO2 and analyze, accurate and durable, Suitable for intubated and nasal tube patients, and more flexible in application environments. Compatible with muiti patient monitor brands.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Sidestream ETCO2 Sensor LH810
Suitable for intubated and non-intubated patients. Plug and play, long service life No calibration required Barometer pressure: CO2, N2O, HE compensation for accurate measurement Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2 Checking and confirming ET tube placement Detecting ventilator airway connection Fully compatible with Respironics module's protocol
 
Specifications of Sidestream ETCO2 Sensor LH810
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading.
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH
 
Compatible Brands:
 

 
Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
 
Click Here To Download Catalogue
   
 
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar