Sidestream Multigas Module AneSure-S

$0.00

Shipped From Abroad

Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-12
Brands:: Kingst

Description

Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution

Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Side Stream Mode

Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.

  • Automatic Pressure Compensation

There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.

  • High-precision

Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Respiration rate Range: 3-150 BPM

Accuracy: ±1% of reading or ±1 rpm whichever is greater

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%,

20 seconds reach the designed deviation.

Rise times (t10- 90 %) CO2:<200ms

N2O, AGENT: <300ms

Flow control Range: 50-250ml/min adjustable

Accuracy: <±20%

Calibration No need to calibrate
Zero Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Sidestream Multigas Module AneSure-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSidestream Multigas Module AneSure-S removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000A Anesthetic Machine removeCWS 5000- Patient Warming Machine removeRender SD-M2000D Anesthetic Machine removeLab/Ward Coat remove
NameSidestream Multigas Module AneSure-S removeTimesco Jumper Fingertip Pulse Oximeter removeRender SD-M2000A Anesthetic Machine removeCWS 5000- Patient Warming Machine removeRender SD-M2000D Anesthetic Machine removeLab/Ward Coat remove
ImageFingertip Pulse Oximeter
SKUSF1033560130170-12SF1033560084-2SF1033560011-13SF103356013087-1SF1033560011-15SF1033560084-222
Rating
Price

$0.00

$17.00

$1,870.00

$1,045.00

$5,940.00

$11.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
  • Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Respiration rate Range: 3-150 BPM Accuracy: ±1% of reading or ±1 rpm whichever is greater
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%, 20 seconds reach the designed deviation.
Rise times (t10- 90 %) CO2:<200ms N2O, AGENT: <300ms
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
Calibration No need to calibrate
Zero Implement when the gas value's offset is observed, or when any unspecified accuracy message is displayed
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
 
Click Here To Download Catalogue
   
 
Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA.
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare