Sidestream Multigas Module AneSure-S
$0.00
Shipped From Abroad
Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Anesthesia Multi-gas Detector AneSure™-S
- Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
- Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
- Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
- High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition | 5°C to 50°C, 10 to 90% RH, non-condensing |
Circumstance pressure | 55-115kpa |
Power consumption | <180 mA |
Interface | RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization |
EtCO2, FiCO2 measurement | Range:0-150 mmHg, 0-20 kPa, 0-19.7%
Accuracy:±2mmHg for CO2 range 0 – 40mmHg ±5% for CO2 range from 41 – 70mmHg ±8% for CO2 range from 71 – 100mmHg ±10% Over 100mmHg |
Respiration rate | Range: 3-150 BPM
Accuracy: ±1% of reading or ±1 rpm whichever is greater |
FiN2O, EtN2O measurement | Range: 0-100%
Accuracy: ± (2 vol% + 2% of reading |
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement | Range: 0-12%
Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified |
FiSEV, EtSEV measurement | Range: 0-15%
Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified |
FiDES, EtDES measurement | Range:0-25%
Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified |
Gas compensation | O2 (HOST supplied), or automatic compensation if O2 equipped |
Barometric Pressure | Having a barometric pressure sensor and automatic compensation |
Warm-up time | 10 seconds reach the designed deviation of 97%,
20 seconds reach the designed deviation. |
Rise times (t10- 90 %) | CO2:<200ms
N2O, AGENT: <300ms |
Flow control | Range: 50-250ml/min adjustable
Accuracy: <±20% |
Calibration | No need to calibrate |
Zero | Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed |
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
- Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
- Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
- Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
- There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
- High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.
Quick Comparison
Settings | Sidestream Multigas Module AneSure-S remove | Siare Morpheus M Anaesthetic Machine remove | Siare Morpheus LT Anaesthetic Machine remove | Oxygen Concentrator 3Ltr. remove | Anesthetic Face Mask remove | Hersill Genesis Anaesthetic Machine remove | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Sidestream Multigas Module AneSure-S remove | Siare Morpheus M Anaesthetic Machine remove | Siare Morpheus LT Anaesthetic Machine remove | Oxygen Concentrator 3Ltr. remove | Anesthetic Face Mask remove | Hersill Genesis Anaesthetic Machine remove | ||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||
SKU | SF1033560101-2 | SF1033560101- 3 | SF1033560084-40 | SF1033560084-141 | SF1033560450-1 | |||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||
Price |
|
|
| $273.00 | $8.00 |
| ||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
| Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||
Content | Features of Anesthesia Multi-gas Detector AneSure™-S
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
Specifications of Anesthesia Multi-gas Detector AneSure-S
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
| The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
Click Here To Download Catalogue) | The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs.
LUNG VENTILATOR
The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02.
Operative Modes:
MAN
VC-VC
PCV-APCV
APCV
P -SIMV
V- SIMV
Measured parameters:
PAW
RATE
VM - VTE
T INSP
Fi02
MANUAL VENTILATION SYSTEM
The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system.
BREATHING SYSTEM
The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue | Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail.
A full 8lpm O2 flowrate capability - gives better performance at lower flow rates
20psi pressure output - your anesthesia system was designed to work from pressure
O2 concentrations average 93% +/- 3%
Built-in Low O2 Concentration Alarm
Small footprint of 15"x15"x22"
Remarkably quiet
Save money over time vs. tanks
Eliminate contamination hazards of tanks coming and going in your facility
Works with ALL manufacturer's brands of anesthesia systems
| Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Features:
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.