Sidestream Multigas Module AneSure-S

$0.00

Shipped From Abroad

Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution

Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Side Stream Mode

Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.

  • Automatic Pressure Compensation

There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.

  • High-precision

Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Respiration rate Range: 3-150 BPM

Accuracy: ±1% of reading or ±1 rpm whichever is greater

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%,

20 seconds reach the designed deviation.

Rise times (t10- 90 %) CO2:<200ms

N2O, AGENT: <300ms

Flow control Range: 50-250ml/min adjustable

Accuracy: <±20%

Calibration No need to calibrate
Zero Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Sidestream Multigas Module AneSure-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSidestream Multigas Module AneSure-S removeSiare Morpheus M Anaesthetic Machine removeSiare Morpheus LT Anaesthetic Machine removeOxygen Concentrator 3Ltr. removeAnesthetic Face Mask removeHersill Genesis Anaesthetic Machine remove
NameSidestream Multigas Module AneSure-S removeSiare Morpheus M Anaesthetic Machine removeSiare Morpheus LT Anaesthetic Machine removeOxygen Concentrator 3Ltr. removeAnesthetic Face Mask removeHersill Genesis Anaesthetic Machine remove
ImageHersill Genesis Anaesthetic Machine
SKUSF1033560101-2SF1033560101- 3SF1033560084-40SF1033560084-141SF1033560450-1
Rating
Price

$0.00

$0.00

$0.00

$273.00

$8.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
  • Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Respiration rate Range: 3-150 BPM Accuracy: ±1% of reading or ±1 rpm whichever is greater
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%, 20 seconds reach the designed deviation.
Rise times (t10- 90 %) CO2:<200ms N2O, AGENT: <300ms
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
Calibration No need to calibrate
Zero Implement when the gas value's offset is observed, or when any unspecified accuracy message is displayed
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. LUNG VENTILATOR The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02. Operative Modes: MAN VC-VC PCV-APCV APCV P -SIMV V- SIMV Measured parameters: PAW RATE VM - VTE T INSP Fi02 MANUAL VENTILATION SYSTEM The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system. BREATHING SYSTEM The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection. Features:
  • Soft cushion for patient comfort and air tight fit
  • Clear flexible housing and cushion for good patient visibility
  • Four sizes available, from small adultl to extra large adult
  • Each mask supplied with color-coded hook ring.
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar