Single Beam Visible Spectrophotometer

$0.00

Shipped From Abroad

Single Beam Visible Spectrophotometer measures the intensity of light absorbed by a sample within the visible spectrum (400-800 nm) using a single beam of light. It’s a straightforward and cost-effective instrument, ideal for applications requiring high sensitivity and precise measurements

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-52
Brands:: Scitek

Description

A single-beam spectrophotometer is a device that uses a single beam of light to measure the light absorption of a substance to determine its concentration, purity and chemical identity. It covers the wavelength range from UV to visible light and provides highly reliable measurements. Single beam spectrophotometer compact, easy to maintain, and have been carefully designed to optimize and simplify your spectrophotometric workflow.

Single Beam Spectrophotometer Features:
  1. Adopting screw structure, wavelength accuracy and resolution yuyiare greatly improved
  2. Can automatically set the wavelength through the direction key to avoid operating errors
  3. Adopting microprocessor control, numeric keys can easily set all parameters.
  4. The single beam visible spectrophotometer is equipped with USB port, can be connected to PC. Spectral scanning, kinetics and multi-wavelength test results can be displayed on the screen.
  5. 8 mm thick rigid die-cast aluminum base is used as an optical mount to ensure the stability and reliability of the instrument.
  6. The single beam visible spectrophotometer can establish various standard curves according to the customer’s solution and determine the concentration of the unknown solution.
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5600 SP-V5800
Optical System Single Beam
Wavelength Range 320-1100nm
Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T ±0.2%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Stability ± 0.001A/h @ 500nm
Baseline Flatness ± 0.002A/h
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display 128×64 Dots LCD
Lamps Tungsten Lamp
Detector Silicon Photodiode
Power Requirements AC 220V/50Hz or 110V/60Hz
Size (W×D×H)(mm) 460x360x225
Shipping Size (W×D×H)(mm) 630x540x380
N.W./G.W. (kg) 16/20

Reviews

There are no reviews yet.

Be the first to review “Single Beam Visible Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSingle Beam Visible Spectrophotometer removeMotic BA210 Series Biomedical Microscope removeHawksley 1400 Haematocrit Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameSingle Beam Visible Spectrophotometer removeMotic BA210 Series Biomedical Microscope removeHawksley 1400 Haematocrit Centrifuge removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageAvalun Labpad machine
SKUSF1033560130127-52SF1033560084-78SF1033560084-118SF1033560084-6SF1033560084-65SF1033560060-2
Rating
Price

$0.00

$0.00

$690.00

$715.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadSingle Beam Visible Spectrophotometer measures the intensity of light absorbed by a sample within the visible spectrum (400-800 nm) using a single beam of light. It's a straightforward and cost-effective instrument, ideal for applications requiring high sensitivity and precise measurements
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentA single-beam spectrophotometer is a device that uses a single beam of light to measure the light absorption of a substance to determine its concentration, purity and chemical identity. It covers the wavelength range from UV to visible light and provides highly reliable measurements. Single beam spectrophotometer compact, easy to maintain, and have been carefully designed to optimize and simplify your spectrophotometric workflow.
Single Beam Spectrophotometer Features:
  1. Adopting screw structure, wavelength accuracy and resolution yuyiare greatly improved
  2. Can automatically set the wavelength through the direction key to avoid operating errors
  3. Adopting microprocessor control, numeric keys can easily set all parameters.
  4. The single beam visible spectrophotometer is equipped with USB port, can be connected to PC. Spectral scanning, kinetics and multi-wavelength test results can be displayed on the screen.
  5. 8 mm thick rigid die-cast aluminum base is used as an optical mount to ensure the stability and reliability of the instrument.
  6. The single beam visible spectrophotometer can establish various standard curves according to the customer's solution and determine the concentration of the unknown solution.
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5600 SP-V5800
Optical System Single Beam
Wavelength Range 320-1100nm
Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T ±0.2%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Stability ± 0.001A/h @ 500nm
Baseline Flatness ± 0.002A/h
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display 128x64 Dots LCD
Lamps Tungsten Lamp
Detector Silicon Photodiode
Power Requirements AC 220V/50Hz or 110V/60Hz
Size (W×D×H)(mm) 460x360x225
Shipping Size (W×D×H)(mm) 630x540x380
N.W./G.W. (kg) 16/20
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare