Single Beam Visible Spectrophotometer

$0.00

Shipped From Abroad

Single Beam Visible Spectrophotometer measures the intensity of light absorbed by a sample within the visible spectrum (400-800 nm) using a single beam of light. It’s a straightforward and cost-effective instrument, ideal for applications requiring high sensitivity and precise measurements

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-52
Brands:: Scitek

Description

A single-beam spectrophotometer is a device that uses a single beam of light to measure the light absorption of a substance to determine its concentration, purity and chemical identity. It covers the wavelength range from UV to visible light and provides highly reliable measurements. Single beam spectrophotometer compact, easy to maintain, and have been carefully designed to optimize and simplify your spectrophotometric workflow.

Single Beam Spectrophotometer Features:
  1. Adopting screw structure, wavelength accuracy and resolution yuyiare greatly improved
  2. Can automatically set the wavelength through the direction key to avoid operating errors
  3. Adopting microprocessor control, numeric keys can easily set all parameters.
  4. The single beam visible spectrophotometer is equipped with USB port, can be connected to PC. Spectral scanning, kinetics and multi-wavelength test results can be displayed on the screen.
  5. 8 mm thick rigid die-cast aluminum base is used as an optical mount to ensure the stability and reliability of the instrument.
  6. The single beam visible spectrophotometer can establish various standard curves according to the customer’s solution and determine the concentration of the unknown solution.
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5600 SP-V5800
Optical System Single Beam
Wavelength Range 320-1100nm
Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T ±0.2%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Stability ± 0.001A/h @ 500nm
Baseline Flatness ± 0.002A/h
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display 128×64 Dots LCD
Lamps Tungsten Lamp
Detector Silicon Photodiode
Power Requirements AC 220V/50Hz or 110V/60Hz
Size (W×D×H)(mm) 460x360x225
Shipping Size (W×D×H)(mm) 630x540x380
N.W./G.W. (kg) 16/20

Reviews

There are no reviews yet.

Be the first to review “Single Beam Visible Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSingle Beam Visible Spectrophotometer removeNikon SMZ745 Stereoscopic Microscope removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameSingle Beam Visible Spectrophotometer removeNikon SMZ745 Stereoscopic Microscope removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageNikon SMZ745 Stereoscopic MicroscopeAvalun Labpad machineDrug Test Cup
SKUSF1033560130127-52SF1033560084-49SF1033560084-65SF1033560084-23SF1033560084-64SF1033560060-2
Rating
Price

$0.00

$0.00

$0.00

$0.00

$4.25

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadSingle Beam Visible Spectrophotometer measures the intensity of light absorbed by a sample within the visible spectrum (400-800 nm) using a single beam of light. It's a straightforward and cost-effective instrument, ideal for applications requiring high sensitivity and precise measurements
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentA single-beam spectrophotometer is a device that uses a single beam of light to measure the light absorption of a substance to determine its concentration, purity and chemical identity. It covers the wavelength range from UV to visible light and provides highly reliable measurements. Single beam spectrophotometer compact, easy to maintain, and have been carefully designed to optimize and simplify your spectrophotometric workflow.
Single Beam Spectrophotometer Features:
  1. Adopting screw structure, wavelength accuracy and resolution yuyiare greatly improved
  2. Can automatically set the wavelength through the direction key to avoid operating errors
  3. Adopting microprocessor control, numeric keys can easily set all parameters.
  4. The single beam visible spectrophotometer is equipped with USB port, can be connected to PC. Spectral scanning, kinetics and multi-wavelength test results can be displayed on the screen.
  5. 8 mm thick rigid die-cast aluminum base is used as an optical mount to ensure the stability and reliability of the instrument.
  6. The single beam visible spectrophotometer can establish various standard curves according to the customer's solution and determine the concentration of the unknown solution.
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5600 SP-V5800
Optical System Single Beam
Wavelength Range 320-1100nm
Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T ±0.2%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Stability ± 0.001A/h @ 500nm
Baseline Flatness ± 0.002A/h
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display 128x64 Dots LCD
Lamps Tungsten Lamp
Detector Silicon Photodiode
Power Requirements AC 220V/50Hz or 110V/60Hz
Size (W×D×H)(mm) 460x360x225
Shipping Size (W×D×H)(mm) 630x540x380
N.W./G.W. (kg) 16/20
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare