Smart-RO Water Purification System

$0.00

Shipped From Abroad

An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-1
Brands:: Hi-Tech

Description

Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter
UF-5000D MWCO5000DUF ultrafiltration component (original imported)
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported)
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube)
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours

Reviews

There are no reviews yet.

Be the first to review “Smart-RO Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSmart-RO Water Purification System removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeAtmosphere Protection Module removeDISSUB ANALYSER removeOXYGEN & CARBON DIOXIDE MONITOR removeVENUS SOLO OEM SENSOR remove
NameSmart-RO Water Purification System removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeAtmosphere Protection Module removeDISSUB ANALYSER removeOXYGEN & CARBON DIOXIDE MONITOR removeVENUS SOLO OEM SENSOR remove
ImageFlowMir Disposable Turbine with Cardboard Mouthpiece
SKUSF1033560130126-1SF1033560084-22SF1033560130141-16SF1033560130141-17SF1033560130141-12SF1033560130141-15
Rating
Price

$0.00

$145.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter -
UF-5000D MWCO5000DUF ultrafiltration component (original imported) -
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported) -
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube) -
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar