Spin Columns

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130143-52
Brands:: CAPP

Description

The anatomy of CAPP Expell Spin Columns

The CAPP Expell spin column system consists of a combination of a 0.8 mL round bottom filter tube and a 1.5/2.0 mL receiver tube that are battle-tested for high performance in a broad range of molecular biology applications. CAPP Expell spin columns have high-quality filter membranes made from a choice of glass fiber filters or polyethylene. Both the filter tube and the receiver tube are manufactured from a unique blend of premium-grade, non-wettable virgin polypropylene that boasts minimum interaction with reaction components. Receiver tubes feature volume graduation marks that make it easy to monitor the amount of product that has been collected during use.

The ideal Spin Columns for high-yield DNA extraction

CAPP Expell spin columns allow for rapid, high-yield DNA extraction from a variety of cells. The resultant high-quality DNA can be used for next-gen sequencing, cloning, and many other downstream applications. After cell lysis, the lysate is added to CAPP Expell spin columns with glass bead filters and the filters will work their magic to retain all the genomic DNA while other cellular components are lost in the flow-through. A quick wash step followed by elution results in a large amount of DNA collected in the receiver tubes of CAPP Expell spin columns, with half the effort required in other less efficient extraction methods.

The best Spin Columns for quick recovery of DNA from agarose gels

The new CAPP Expell spin column system offers a single-step nucleic acid binding matrix for all the precious DNA harvested from agarose gels. After excising the band of interest from the gel, the band is just added to a CAPP Expell spin column with a binding buffer and all DNA will remain bound to the high-affinity glass bead filter membranes. CAPP Expell spin columns also feature an eco-friendly blend of polypropylene with minimal reaction interference guaranteed. This means you get to maximize DNA recovery from your successful agarose gel electrophoresis runs while doing your part to keep the environment a better place for all of us.

Exceptional PCR purification with CAPP Expell Spin Columns

After running a successful polymerase chain reaction (PCR) it is often essential to purify the PCR products, separating them from primers, enzymes, and other components of the reaction mix. CAPP Expell spin columns with glass fiber filters offer the perfect DNA binding matrix (~99.99% efficiency) for PCR products, ensuring maximum recovery of amplicons from the reaction mix. The reversible binding of DNA to the innovative glass fiber filter technology of CAPP Expell spin columns makes quick work of the elution step, speeding up your PCR clean-up workflow. CAPP Expell spin columns are your ideal partner in the purification and clean-up of PCR products.

Spin Columns optimized for plasmid preparation

CAPP Expell spin columns are fine-tuned to work with a broad range of protocols that use plasmid miniprep kits. With CAPP Expell spin columns, harvesting plasmid DNA from bacterial cells is quick and easy thanks to the high-efficiency silica-based glass fiber filter membranes. By using silica-based technology, CAPP Expell spin columns consistently achieve an industry-leading plasmid DNA binding affinity upwards of 99.99% while maintaining a high flow rate and particle loading capacity. With CAPP Expell spin columns, impactful science doesn’t have to cost a fortune in overpriced accessories for commercial miniprep kits.

Specification
Cat. No. Description
5052001C Expell spin column 0.8 mL, GF-F2, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5052002C Expell spin column 0.8 mL, GF-N2, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5052003C Expell spin column 0,8 mL PE 20-60 µm, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5050800C Expell spin column 0.8 mL, without filter, bag, 1000 pcs. filter tubes and 1000 pcs. filter rings
5052000C Expell receiver tube 2.0mL, bag, 10x 1000 pcs.

Reviews

There are no reviews yet.

Be the first to review “Spin Columns”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSpin Columns removeErlenmeyer Flasks with Flat Cap removeDiagnostic Specimen Container removeCell Culture Plates removeBlood Collection Dressing Kit removeEmbedding Cassette remove
NameSpin Columns removeErlenmeyer Flasks with Flat Cap removeDiagnostic Specimen Container removeCell Culture Plates removeBlood Collection Dressing Kit removeEmbedding Cassette remove
Image
SKUSF1033560130143-52SF1033560130125-73SF1033560130117-4SF1033560130125-71SF1033560130104-31SF1033560130102-86
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Flat-bottomed erlenmeyer flask saves preparation time and avoids the risk of contamination, making it an ideal choice for cell suspension culture, medium configuration, mixing and storage. The high clarity flask is firm and hard to crack, which reduces any personnel safety risks and is an ideal choice for shaker culture applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Watertight container made of ABS. It maintains the internal temperature between 6 and 10ºC for 24 hours. It is certified with the ADR/OACI/IATA Packing instructions P620 and P650 – Class 6.2 (4H2):
  • UN 3373 Biological Substance Category B
  • UN 2814 Infectious substance, affecting humans
  • UN 2900 Infectious substance, affecting animals
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This product is mainly composed of tourniquet, drape, povidone-iodine prep swab, infusion paste, adhesive wound dressing and paper-plastic packaging bag. (Can be customized according to clinical needs).
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
The anatomy of CAPP Expell Spin Columns
The CAPP Expell spin column system consists of a combination of a 0.8 mL round bottom filter tube and a 1.5/2.0 mL receiver tube that are battle-tested for high performance in a broad range of molecular biology applications. CAPP Expell spin columns have high-quality filter membranes made from a choice of glass fiber filters or polyethylene. Both the filter tube and the receiver tube are manufactured from a unique blend of premium-grade, non-wettable virgin polypropylene that boasts minimum interaction with reaction components. Receiver tubes feature volume graduation marks that make it easy to monitor the amount of product that has been collected during use.
The ideal Spin Columns for high-yield DNA extraction
CAPP Expell spin columns allow for rapid, high-yield DNA extraction from a variety of cells. The resultant high-quality DNA can be used for next-gen sequencing, cloning, and many other downstream applications. After cell lysis, the lysate is added to CAPP Expell spin columns with glass bead filters and the filters will work their magic to retain all the genomic DNA while other cellular components are lost in the flow-through. A quick wash step followed by elution results in a large amount of DNA collected in the receiver tubes of CAPP Expell spin columns, with half the effort required in other less efficient extraction methods.
The best Spin Columns for quick recovery of DNA from agarose gels
The new CAPP Expell spin column system offers a single-step nucleic acid binding matrix for all the precious DNA harvested from agarose gels. After excising the band of interest from the gel, the band is just added to a CAPP Expell spin column with a binding buffer and all DNA will remain bound to the high-affinity glass bead filter membranes. CAPP Expell spin columns also feature an eco-friendly blend of polypropylene with minimal reaction interference guaranteed. This means you get to maximize DNA recovery from your successful agarose gel electrophoresis runs while doing your part to keep the environment a better place for all of us.
Exceptional PCR purification with CAPP Expell Spin Columns
After running a successful polymerase chain reaction (PCR) it is often essential to purify the PCR products, separating them from primers, enzymes, and other components of the reaction mix. CAPP Expell spin columns with glass fiber filters offer the perfect DNA binding matrix (~99.99% efficiency) for PCR products, ensuring maximum recovery of amplicons from the reaction mix. The reversible binding of DNA to the innovative glass fiber filter technology of CAPP Expell spin columns makes quick work of the elution step, speeding up your PCR clean-up workflow. CAPP Expell spin columns are your ideal partner in the purification and clean-up of PCR products.
Spin Columns optimized for plasmid preparation

CAPP Expell spin columns are fine-tuned to work with a broad range of protocols that use plasmid miniprep kits. With CAPP Expell spin columns, harvesting plasmid DNA from bacterial cells is quick and easy thanks to the high-efficiency silica-based glass fiber filter membranes. By using silica-based technology, CAPP Expell spin columns consistently achieve an industry-leading plasmid DNA binding affinity upwards of 99.99% while maintaining a high flow rate and particle loading capacity. With CAPP Expell spin columns, impactful science doesn’t have to cost a fortune in overpriced accessories for commercial miniprep kits.

Specification
Cat. No. Description
5052001C Expell spin column 0.8 mL, GF-F2, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5052002C Expell spin column 0.8 mL, GF-N2, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5052003C Expell spin column 0,8 mL PE 20-60 µm, bag, 100 pcs. filter tubes and 100 pcs. receiver tubes 2,0mL
5050800C Expell spin column 0.8 mL, without filter, bag, 1000 pcs. filter tubes and 1000 pcs. filter rings
5052000C Expell receiver tube 2.0mL, bag, 10x 1000 pcs.
Flat-bottomed erlenmeyer flask saves preparation time and avoids the risk of contamination, making it an ideal choice for cell suspension culture, medium configuration, mixing and storage. The high clarity flask is firm and hard to crack, which reduces any personnel safety risks and is an ideal choice for shaker culture applications.https://youtu.be/fEvSbXIQlUE Features
  • It offers the safest and easiest closing system on the market
  • High impact resistance
  • Different accessories available
  • Stackable
  • Designed to maximise space utilisation during transportation
Dimensions
  • Dimensions: 50×38.3×40.4 cm
  • Nominal capacity: 25 litres
  • Test tubes: Accommodates 300 tubes
  • Secondary tubes: Accommodates 6 units
  • Max. load: 6 kg
  • Carton dimensions: 51×39,5×40,5 cm
Accessories termografo    carro Bioclinic    Acumulador de frio Bioclinic
Features
● Electron beam sterilization ● Vacuum plasma treatment ● DuPont Tyvek hot melt independent packaging, moistureproof, waterproof ● Free from pyrogens and endotoxins ● Made from high clarity, 100% polystyrene ● Clear lot numbers for batch traceability

● Products are available in bags or with brackets

Product Description

This product is mainly composed of tourniquet, drape, povidone-iodine prep swab, infusion paste, adhesive wound dressing and paper-plastic packaging bag. (Can be customized according to clinical needs).

Product Performance

A. Disposable use to avoid iatrogenic infection; B. Sterile products; C. Integral sterilization, ready for use, safe and convenient for use; D. Compliance with the regulation of “strictly implement aseptic operation procedures, venous blood collection must be one person, one needle, one tube, one towel and one belt” as required by the Ministry of Health in Hospital Infection Management Regulations.

Product Usage

Applicable to blood collection in hospital laboratory and blood collection in blood station It is quick, convenient, safe, and greatly reduces the labor intensity of nursing staff

Precautions

1. This product is sterilized by ethylene oxide and is safe and convenient to use; 2. The sterilization period of this product is limited to two years. If the package is damaged, it is forbidden to use; 3. For the production date and batch number, see the spray code; 4. This product is for single use, and it shall be destroyed in a centralized manner after use. Repeated use is strictly prohibited.

Chuangqi Nursing Kit Products

Item Number Product Usage Specification
Disposable Dressing Kit PICC Puncture Care Kit ACC
Disposable Dressing Kit PICC Puncture Dressing Kit AWH
Disposable Dressing Kit Neonate Puncture Kit ACC-XS
Disposable Dressing Kit Infusion Dressing Kit BSY
Disposable Dressing Kit Infusion Dressing Kit(high configuration) BSY-H
Disposable Dressing Kit Blood Collection Dressing Kit BCX
Disposable Dressing Kit Blood Collection Dressing Kit(for Blood Station) BCX
Disposable Dressing Kit IV Start Kit BLZ-M
Disposable Dressing Kit IV Start Kit BLZ-S
Disposable Dressing Kit Dressing Change Kit CHY-75
Disposable Dressing Kit Dressing Change Kit CHY-15
Disposable Dressing Kit Dressing Change Kit CHY-25
Disposable Dressing Kit Dialysis Dressing Kit DTX
Disposable Dressing Kit Suture Remove Kit ECX
Disposable Dressing Kit Skin Prep Kit FBP
Disposable Dressing Kit Dental Exam Kit Type A
Disposable Dressing Kit Dental Exam Kit Type B
REF Description Qty.Cs
GCL802 Embedding Cassette 4000
GCL802-1 Embedding Cassette 4000
GCL802-2 Embedding Cassette 4000
GCL803 Embedding Cassette 4000
GCL803-1 Embedding Cassette 4000
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare