SPROTTE-Needles for Atraumatic Spinal Anaesthesia
$4.20
Shipped From Abroad
With the introduction of the first atraumatic Sprotte needle at the end of the 1970s, spinal anesthesia was rehabilitated as a fully accepted alternative to general anesthesia. A unique tip design is the secret of its success. Sprotte ́s atraumatic puncture and optimal gliding properties minimize possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space while reducing the incidence of post-dural puncture headache (PDPH).
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features & Advantages
Atraumatic Tip Design
- The ogive shaped tip significantly reduces the risk of PDPH and the rounded edges of the lateral eye minimise trauma to the dura mater
- Minimises chance of PDPH3
- Consistent tactile feedback
Lateral Eye
- Burr-free rounded atraumatic edges
- Optimized gliding properties
- Minimum chance of tissue coring and carry-over into the subarachnoid space
Highest Processing Quality
- High-quality stainless steel needle for increased stability
- Smoothly polished and burr-free surface and inner lumen designed for optimized gliding properties and CSF backflow
- Consistent feel and reliable performance
Optimal Lateral Eye Size and Placement
- Unobstructed backflow, even if the eye is partially blocked by the arachnoid membrane
- Allows for quicker CSF flashback
Precision-Ground Metal Stylet
- Lateral eye closes precisely to minimize chance of tissue coring2
- Polished, rounded tip prevents abrasion on the inner needle tube
Standard Hub
- Designed for rapid detection of even the smallest quantities of CSF
- Reduced inner space
Magnifying Hub
- Clear, magnifying needle hub allows for easy visualization of blood or CSF
- Easier detection of CSF flashback
Color-coded Needle Hub with Size Indication
- Easy identification of needle size
Introducer with Facet Tip
- Diameter and length perfectly matched to each spinal needle size
- Minimal reduction of useable working length of the spinal needle
- Funnel-shaped hub to reduce the chance of spinal needle tip damage during insertion
Portfolio Excellence
- Wide needle range with different diameters and lengths
- Special designs for pediatrics and obese patients
Quick Comparison
Settings | SPROTTE-Needles for Atraumatic Spinal Anaesthesia remove | Guedel Oropharyngeal Airway remove | Hearing Aid remove | Complete Oxygen Cylinder with Accessories remove | Farmkit Sprayer remove | Patella Hammer remove | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | SPROTTE-Needles for Atraumatic Spinal Anaesthesia remove | Guedel Oropharyngeal Airway remove | Hearing Aid remove | Complete Oxygen Cylinder with Accessories remove | Farmkit Sprayer remove | Patella Hammer remove | ||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||
SKU | SF1033560084-47 | SF1033560084-119 | SF1033560084-60 | SF1033560084-45 | SF1033560084-110 | |||||||||||||||||
Rating | ||||||||||||||||||||||
Price | $4.20 | $1.00 | $16.90 | $59.00 |
| $2.50 | ||||||||||||||||
Stock | ||||||||||||||||||||||
Availability | ||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||
Description | Shipped From Abroad
With the introduction of the first atraumatic Sprotte needle at the end of the 1970s, spinal anesthesia was rehabilitated as a fully accepted alternative to general anesthesia. A unique tip design is the secret of its success. Sprotte ́s atraumatic puncture and optimal gliding properties minimize possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space while reducing the incidence of post-dural puncture headache (PDPH).
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock Oxygen Cylinder with Safety Cover Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Farmkit Sprayer: Comfortable to use,medical chest is designed according to human body physical characteristic .Main parts use high quality materials and the latest processing technology .The bowl is made by corrosion-resistant and wear-resistant materials.Series products of large capacity of the air compartment,large flow piston pump,easy operation,quick pressure arising,labor-saving,anti leakage and both right and left hand operation. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||
Content | Features & AdvantagesAtraumatic Tip Design
Lateral Eye
Highest Processing Quality
Optimal Lateral Eye Size and Placement
Precision-Ground Metal Stylet
Standard Hub
Magnifying Hub
Color-coded Needle Hub with Size Indication
Introducer with Facet Tip
Portfolio Excellence
| Guedel Oropharyngeal Airway: This is used to create an air passage way between the mouth and the posterior pharyngeal wall. Useful when the tongue and/or epiglottis fall back against the posterior pharynx in anesthetized or unconscious patients obstructing the flow of air.
Technical Specifications:
|
| Oxygen Cylinder with Safety Cover | Farmkit Sprayer: Comfortable to use,medical chest is designed according to human body physical characteristic .Main parts use high quality materials and the latest processing technology .The bowl is made by corrosion-resistant and wear-resistant materials.Series products of large capacity of the air compartment,large flow piston pump,easy operation,quick pressure arising,labor-saving,anti leakage and both right and left hand operation.
Features:
|
| ||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Additional information |
Reviews
There are no reviews yet.