STERISHRED 250
$0.00
Shipped From Abroad
THE ON-SITE SOLUTION TO CONVERT INFECTIOUS MEDICAL WASTE INTO MUNICIPAL
TRASH IN MINUTES!
STERISHRED 250 is a modern compact on-site solution for treating infectious healthcare waste using a non-burn thermal process (steam sterilization) at 135°C. It simultaneously shreds and sterilizes biohazardous waste including sharps in minutes!
Click here to download Catalogue
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
Ideal for bagged waste treatment
Its loading method facilitates the processing of medical waste in bags.
Easy to use
With an ergonomic interface, this solution offers a simple alternative to the treatment of waste with infectious risks.
Cycle speed and efficiency
STERISHRED® 250 allows to treat 15 to 25KG of infectious waste, in 40 to 50 min.
Technical Data
LOADING CHAMBER CAPACITY |
170 L |
DRAIN |
Inner 32 mm Ø (heat resistant, floor level) |
STEAM |
Produced by the integrated steam generator, no external connection required |
COMPRESSED AIR |
Air compressor built-in |
TOTAL CYCLE TIME |
Approx. 30 to 35 min depending on steam generator version and load humidity |
LOADING CAPACITY (KG/CYCLE) |
10 to 25 kg/cycle (Based on an average waste density of 0,12 to 0,2 kg/l) |
TOTAL CYCLE TIME IN WORKING CONDITIONS (2) |
30 to 50 min |
TREATMENT CAPACITY (KG/H) (3) |
14 to 35 kg/h (Based on an average waste density of 0,12 to 0,2 kg/l) |
EXTERNAL DIMENSIONS (HxWxD) |
1918 mm (2765 incl. pusher) x 1900 mm x 1209 mm |
NET WEIGHT |
1 750 kg |
LOADING CHAMBER |
Stainless steel |
TREATMENT CHAMBER |
316L Stainless steel |
STEAM GENERATOR |
Stainless steel |
WATER SOFTENER |
Available as option (External) |
WATER BOOSTER PUMP |
Available as option (External) |
WASTE SHREDDER |
AISI 304L stainless steel (structure) Hardox® hard steel (blades) |
PIPING |
Stainless steel/PTFE flexible hosing |
CHASSIS |
Powder coated steel |
BODYWORK |
Stainless steel |
CYCLE TRACEABILITY |
Built-in printer |
Utilities
WATER | |
Requirements | Softened water 4-8°TH |
Consumption | Approx. 40 liters/cycle (15L machine + 25L steam generator) |
ELECTRICITY | |
Requirements | 380-400 V III N, 50/60 Hz, 40 Kw |
Consumption | 5 Kwh/cycle |
Quick Comparison
Settings | STERISHRED 250 remove | RZ Medizintechnik Complete Endoscopy Stack remove | Yuwell 7F-10 Oxygen Concentrator remove | BEING BBC-3S1 Biosafety Cabinet remove | Keewell Gel Warmer KGW-2 remove | ADE M318800 Mechanical Column Scale with Height Rod remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | STERISHRED 250 remove | RZ Medizintechnik Complete Endoscopy Stack remove | Yuwell 7F-10 Oxygen Concentrator remove | BEING BBC-3S1 Biosafety Cabinet remove | Keewell Gel Warmer KGW-2 remove | ADE M318800 Mechanical Column Scale with Height Rod remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF103356013097-4 | SF1033560074 | SF1033560090 | SF1033560101 | SF1033560086 | SF1033560100 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
| $759.00 |
| $175.00 | $129.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
THE ON-SITE SOLUTION TO CONVERT INFECTIOUS MEDICAL WASTE INTO MUNICIPAL TRASH IN MINUTES! STERISHRED 250 is a modern compact on-site solution for treating infectious healthcare waste using a non-burn thermal process (steam sterilization) at 135°C. It simultaneously shreds and sterilizes biohazardous waste including sharps in minutes! Click here to download CatalogueDelivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
| Shipped From Abroad
KEY FEATURES
| Shipped From Abroad
This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature.
By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Eye-level beam scale, readable from both sides, with a telescopic height measuring rod and two transport castors for easy movability. The solid scale is made of steel and comes with a heavy duty iron lever system, guaranteeing a long and trouble-free life time.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | https://youtu.be/W2QTSINChh4?si=eVUr9251lLvOZlmZ
![]() ![]() ![]() FeaturesIdeal for bagged waste treatment
Its loading method facilitates the processing of medical waste in bags.
Easy to use
With an ergonomic interface, this solution offers a simple alternative to the treatment of waste with infectious risks.
Cycle speed and efficiency
STERISHRED® 250 allows to treat 15 to 25KG of infectious waste, in 40 to 50 min.
Technical Data
Utilities
| RZ LED iLumen EndoVue 24"Features:
Full HD Digital Camera System F 1Features:
LUMEN LED 1 High Intensity Light Source 180WFeatures:
AIRFLOW A2 INSUFFLATORFeature:
**SUCTION AND IRRIGATION PUMP P1000Feature:
**DIATHERMY MACHINE 200WFeature:
HIGH-END TROLLEYFeature:
Accessory
Click Here To Download Catalogue | KEY FEATURES
Technical Specification:
| This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Features:
LCD large screen
Ergonomic 5 ° inclination design
Backlight design to relieve eyesight fatigue
Platform type hand rest
304 stainless steel liner
Timing function
Easy to clean and disinfect
Technical Specification:
Internal Dimensions (W×D×H) mm: 920×580×655
External Dimensions (W×D×H) mm: 1040×810×2100
Downflow Velocity: 0.33m/s
Inflow Velocity: 0.33m/s
Working Access Opening Height: 200mm
Opening MAX.: 450mm
HEPA Filter Typical Efficiency: 99.99% @ 0.3µm
Noise: <65dB
Fluorescent Lamp Intensity: >900Lux
| A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. FEATURES: High bright LED display Adjustable temperature control range 34-40℃ Programmable timer to switch on and switch off 360 degree surround heater unit Digital temperature control technology High energy efficiency Ergonomic design Built-in durable waIl mountable construction STANDARDS CONFORMED TO: EN 55014-1: 2006+A1:2009 EN 55014-2: 1997+A2:2008 EN 61000-3-2: 2006+A2:2009 EN 61000-3-3: 2008 EN 60335-1: 2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008+A14:2010 EN 62233:2008 SPECIFICATIONS: Power Supply: AC100-240V, 50/60Hz, 30VA; DC12V, 2A Operating Ambient Temperature: 0-40℃ Operating Relative Humidity: 30-90% Temperature Control Range: 34-40℃ Temperature Control Accuracy: ± 1℃ (After Heat Balance) Auto Switch On Timer: 00:00-23:59 Auto Switch Off Timer: 00:00-23:59 | Eye-level beam scale, readable from both sides, with a telescopic height measuring rod and two transport castors for easy movability. The solid scale is made of steel and comes with a heavy duty iron lever system, guaranteeing a long and trouble-free life time. Features: With a telescopic height measuring rod and two transport castors Manual zero setting Height measuring Eye-level beam scale readable from both sides Heavy duty iron level system Solid scale made of steel Technical data Physician scale: Capacity 200 kg Graduation 100 g Units kg, kg/lbs Dimensions weighing platform 275 x 375 mm Dimensions overall 275 x 560 x 1485 Weight - 18 kg Telescopic height measuring rod: Length measuring range - 600 – 2100 mm Graduation - 1 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | 50 kg | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | 120 × 350 × 150 cm | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
|
Reviews
There are no reviews yet.