Ultrasonic Vascular Doppler Detector Bi

Ask for Price$0.00

Shipped From Abroad

Feature:

620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It  prints the monitoring blood flow curve simultaneously;

Detect the blood stream status of arterial/venous by 8MHz probe;

Detect the blood flow average velocity, detect the result of fingers/toes and part of body’s vein anatomies operation;

BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen;

Built-in ARM microprocessor & real-time displays blood flow velocity waveform;

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013038
Brands:: Bestman

Description

Feature:

620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It  prints the monitoring blood flow curve simultaneously;

Detect the blood stream status of arterial/venous by 8MHz probe;

Detect the blood flow average velocity, detect the result of fingers/toes and part of body’s vein anatomies operation;

BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen;

Built-in ARM microprocessor & real-time displays blood flow velocity waveform;

Can store 50 detected waveforms;

High-speed USB/RS -232 port, can be connected directly to computer to analyze, store, and print the waveform data;

Detect peak and average blood speed

Detect blood flow of peripheral vessel

Detect subsection systolic pressure

Detect phlebostenosis, vein occlusions

Detect Systolic pressure of toes and fingers

Detect blood speed during recovery

Detect the pulse rate and show PR simultaneously

Specification:

Frequency range:Main unit:200±80~5000±1000HZ

Probe:350±80~2500±500HZ

External output:loudspeaker, single channel with earphone jack

Emissive waveform: sine wave

Ultrasonic frequency:5.0MHz±10% 、8.0MHz ±10%

Ultrasonic frequency average intensity: < 50mW/cm2

Velocity measure range:0~100 cm /s.

Test error:≤20%(relative error)

Overall sensitivity:> 100dB

Printing speed:40cm/min,60cm/min ,display synchronize with print

Frequency mode display range:0.2 KHz~7.0 KHz

LCD Display:128 X 64 dots, LCD cursor indicates blood stream speed, double display mode for the spectrum and velocity.

Power indication: blue LED indication

Charge indication: the charge indicator is yellow when charging and become green after full charge

Alarm indication: the indicator light is red when the lack of battery

Lack of paper indication: When the recorder is lack of paper, the indication light is red

Outline dimension:210*220*105 (mm)

Net weight:1.9 Kg

Environment condition:

Temperature:+5℃ ~ +40℃ ,

Humidity:<80%,

Atmospheric pressure:86kPa ~ 106kPa.

Transport and storage environment:

Temperature:-10℃ ~ +55℃ ,

Humidity:<80%,

Atmospheric pressure:86kPa ~ 106kPa

Reviews

There are no reviews yet.

Be the first to review “Ultrasonic Vascular Doppler Detector Bi”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsUltrasonic Vascular Doppler Detector Bi removeInstrument Tray removeSyringe Needle Destroyer removeStainless Steel Hospital Two Step Stool removeWash Hand Bowl with Stand removeUrine Analyzer remove
NameUltrasonic Vascular Doppler Detector Bi removeInstrument Tray removeSyringe Needle Destroyer removeStainless Steel Hospital Two Step Stool removeWash Hand Bowl with Stand removeUrine Analyzer remove
Image
SKUSF103356013038SF1033560084-199SF1033560084-206SF1033560084-204SF1033560084-246SF1033560084-224
Rating
Price

Ask for Price$0.00

$6.90

$157.00

$27.00

$36.00

$540.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Feature: 620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It  prints the monitoring blood flow curve simultaneously; Detect the blood stream status of arterial/venous by 8MHz probe; Detect the blood flow average velocity, detect the result of fingers/toes and part of body's vein anatomies operation; BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen; Built-in ARM microprocessor & real-time displays blood flow velocity waveform;  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Instrument Trays are also called as Surgical Trays , Medical Trays & Hospital Trays.
  • They are 18/8 Gauge with thickness of 0.50mm.
  • It is manufactured with stainless steel 304 grade without having any sharp edges.
  • They have seamless jointless construction.
  • These are supplied with cover.
  • These are used for safe storage, application & sterilization of Surgical Instruments.
  • These Stainless Steel Trays are durable & Reusable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Features:
  • Extra-wide tops
  • Chrome-plated, reinforced base
  • Dimensions:  Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
  • Weight capacity: 600 lbs.
  • Skid resistant rubber mat for safety
Manufacturer warranty: 5 years
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Product name Wash-hand stand
Model BC316-2
Size 660*320*810mm
Bowl qty double
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentFeature: 620VP TFT LCD displays the wave of the instant blood flow average velocity and strength. It  prints the monitoring blood flow curve simultaneously; Detect the blood stream status of arterial/venous by 8MHz probe; Detect the blood flow average velocity, detect the result of fingers/toes and part of body's vein anatomies operation; BV-620VP(TFT) portable bidirectional vascular Doppler with large color LCD screen; Built-in ARM microprocessor & real-time displays blood flow velocity waveform; Can store 50 detected waveforms; High-speed USB/RS -232 port, can be connected directly to computer to analyze, store, and print the waveform data; Detect peak and average blood speed Detect blood flow of peripheral vessel Detect subsection systolic pressure Detect phlebostenosis, vein occlusions Detect Systolic pressure of toes and fingers Detect blood speed during recovery Detect the pulse rate and show PR simultaneously Specification: Frequency range:Main unit:200±80~5000±1000HZ Probe:350±80~2500±500HZ External output:loudspeaker, single channel with earphone jack Emissive waveform: sine wave Ultrasonic frequency:5.0MHz±10% 、8.0MHz ±10% Ultrasonic frequency average intensity: < 50mW/cm2 Velocity measure range:0~100 cm /s. Test error:≤20%(relative error) Overall sensitivity:> 100dB Printing speed:40cm/min,60cm/min ,display synchronize with print Frequency mode display range:0.2 KHz~7.0 KHz LCD Display:128 X 64 dots, LCD cursor indicates blood stream speed, double display mode for the spectrum and velocity. Power indication: blue LED indication Charge indication: the charge indicator is yellow when charging and become green after full charge Alarm indication: the indicator light is red when the lack of battery Lack of paper indication: When the recorder is lack of paper, the indication light is red Outline dimension:210*220*105 (mm) Net weight:1.9 Kg Environment condition: Temperature:+5℃ ~ +40℃ , Humidity:<80%, Atmospheric pressure:86kPa ~ 106kPa. Transport and storage environment: Temperature:-10℃ ~ +55℃ , Humidity:<80%, Atmospheric pressure:86kPa ~ 106kPa
  • Instrument Trays are also called as Surgical Trays , Medical Trays & Hospital Trays.
  • They are 18/8 Gauge with thickness of 0.50mm.
  • It is manufactured with stainless steel 304 grade without having any sharp edges.
  • They have seamless jointless construction.
  • These are supplied with cover.
  • These are used for safe storage, application & sterilization of Surgical Instruments.
  • These Stainless Steel Trays are durable & Reusable.
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Features:
  • Extra-wide tops
  • Chrome-plated, reinforced base
  • Dimensions:  Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
  • Weight capacity: 600 lbs.
  • Skid resistant rubber mat for safety
Manufacturer warranty: 5 years
Product name Wash-hand stand
Model BC316-2
Size 660*320*810mm
Bowl qty double
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar