Ultrasonic Vascular Doppler Detector
$4,378.00
Shipped From Abroad
Feature:
1. Obtains two pressures at each ankle site (PVR and DOPPLER)
2. Automated segmental studies to customize the item
3. Automatic ABI, TBI and segmental calculation
4. Performs the Seated ABI on mobility impaired patients
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Feature:
1. Obtains two pressures at each ankle site (PVR and DOPPLER)
2. Automated segmental studies to customize the item
3. Automatic ABI, TBI and segmental calculation
4. Performs the Seated ABI on mobility impaired patients
5. Bi-Directional Doppler probe
6. PVR waveform modality & PPG probe to obtain toe and limb pressures
Specification
Ankle-brachial index(ABI),toe-Brachial Index(TBI) ,segment exams, automatic calculation of the indices
Control mode: automatic cuff inflation/deflation and hand-held controller
Wave mode: bi-directional doppler, pulse volume recording(PVR), photoplethysmography(PPG)
Doppler specification: bi-directional continuous wave(CW), waveform amplitude accuracy:+/- 10%,
Probe: 8MHz
PPG specification: wave length:940nm, synchronous demodulation, AC paired
PVR specification: bandwidth 0.16-12.5Hz, AC paried
Display: 5.6inch, TFT, (640*RGB*480)
Printer: paper width:80mm, printing width:70mm, resolution 8 points/mm
Data storage and transmission: maximum store 100 patient’s data, transmission to computer via USB 2.0
Power supply:100-240VAC, 50-60Hz
Quick Comparison
Settings | Ultrasonic Vascular Doppler Detector remove | Instrument Tray remove | Medical Safety Google remove | Syringe Needle Destroyer remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | Feeding Table remove |
---|---|---|---|---|---|---|
Name | Ultrasonic Vascular Doppler Detector remove | Instrument Tray remove | Medical Safety Google remove | Syringe Needle Destroyer remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | Feeding Table remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF103356013037 | SF1033560084-199 | SF1033560084-196 | SF1033560084-206 | SF1033560098-13 | SF1033560084-195 |
Rating | ||||||
Price | $4,378.00 | $6.90 | $1.99 | $157.00 |
| $31.50 |
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Feature:
1. Obtains two pressures at each ankle site (PVR and DOPPLER)
2. Automated segmental studies to customize the item
3. Automatic ABI, TBI and segmental calculation
4. Performs the Seated ABI on mobility impaired patients
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
|
Content | Feature: 1. Obtains two pressures at each ankle site (PVR and DOPPLER) 2. Automated segmental studies to customize the item 3. Automatic ABI, TBI and segmental calculation 4. Performs the Seated ABI on mobility impaired patients 5. Bi-Directional Doppler probe 6. PVR waveform modality & PPG probe to obtain toe and limb pressures Specification Ankle-brachial index(ABI),toe-Brachial Index(TBI) ,segment exams, automatic calculation of the indices Control mode: automatic cuff inflation/deflation and hand-held controller Wave mode: bi-directional doppler, pulse volume recording(PVR), photoplethysmography(PPG) Doppler specification: bi-directional continuous wave(CW), waveform amplitude accuracy:+/- 10%, Probe: 8MHz PPG specification: wave length:940nm, synchronous demodulation, AC paired PVR specification: bandwidth 0.16-12.5Hz, AC paried Display: 5.6inch, TFT, (640*RGB*480) Printer: paper width:80mm, printing width:70mm, resolution 8 points/mm Data storage and transmission: maximum store 100 patient’s data, transmission to computer via USB 2.0 Power supply:100-240VAC, 50-60Hz |
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
| Observation mode: Brightfield.
Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives:
N-PLAN 4x/0.10
N-PLAN 10x/0.25
N-PLAN 40x/0.65
N-PLAN 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.
Click Here To Download Catalogue |
| |
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.