UV Visible Spectrophotometer

$0.00

Shipped From Abroad

Model : SP-DUV8000; SP-DUV8000I

The UV-Visible Spectrophotometer measures the absorption of light in the ultraviolet (UV) and visible parts of the spectrum (typically 200-800 nm). It’s used to determine the concentration of substances in a sample by analyzing the light absorbed at various wavelengths. This makes it a powerful tool in research, chemistry, biology, and materials science.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-66
Brands:: Scitek

Description

UV VIS Spectrophotometer Features:
  • Dual-beam system, dual detectors, the use of high-performance imported grating, lower stray light, more reliable, stable, analysis and more accurate
  • Equipped with 10-inch touch screen, built-in 32G memory, support for Bluetooth connection
  • Built-in mainframe can enter the calibration curve
  • Adopts the suspension design of the optical system, 16mm thick aluminum non-deformation base to prevent deformation.
  • Powerful storage function, can be directly connected to the printer for A4 format data and graphics printing
  • With automatic start function, calibration, and system positioning function.
  • Can export data to U disk.

 

UV VIS Spectrophotometer Specifications:
Model SP-DUV8000 SP-DUV8000I
Wavelength Range 190-1100nm
Spectral Bandwidth 1.8 nm 0.5, 1.0 2.0, 4.0nm
Wavelength Accuracy ±0.1nm (D2 656.1nm), ±0.3 nm full range
Stray Light 0.03% T @ 220 nm, 360 nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.2T(0-1009%T)
±0.002Abs(0-0.5Abs)
±0.004Abs(0.5-1.0Abs)
Photometric Repeatability ≤0.05%6T(0-100%6T)
0.001Abs(0-0.5Abs)
0.002Abs(0.5-1.0Abs)
Stability ±0.0004A/h@500nm
Photometric Range 0-200%T, -0.3-3.0A, 0-9999C
Baseline Flatness ±0.001A
Noise ±0.0004A
Display 800×480 touch screen
Data Output Port USB
Print Port USB Port
Light Source Tungsten Lamp & Deuterium Lamp
Power Requirements AC220V/50Hz or 110v/60Hz
Detector Silicon Photodiode
Size(W×D×H)(mm) 630x430x210
Shipping Size(W×D×H)(mm) 850x650x450
N.W./G.W. (kg) 28/38

Reviews

There are no reviews yet.

Be the first to review “UV Visible Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

UV Visible Spectrophotometer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameUV Visible Spectrophotometer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageNikon SMZ745 Stereoscopic Microscope
SKUSF1033560130127-66SF1033560084-30SF1033560060-2SF1033560084-49SF1033560084-129SF1033560084-125
Rating
Price

$0.00

$9.50

$0.00

$0.00

$0.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-DUV8000; SP-DUV8000I The UV-Visible Spectrophotometer measures the absorption of light in the ultraviolet (UV) and visible parts of the spectrum (typically 200-800 nm). It's used to determine the concentration of substances in a sample by analyzing the light absorbed at various wavelengths. This makes it a powerful tool in research, chemistry, biology, and materials science.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
UV VIS Spectrophotometer Features:
  • Dual-beam system, dual detectors, the use of high-performance imported grating, lower stray light, more reliable, stable, analysis and more accurate
  • Equipped with 10-inch touch screen, built-in 32G memory, support for Bluetooth connection
  • Built-in mainframe can enter the calibration curve
  • Adopts the suspension design of the optical system, 16mm thick aluminum non-deformation base to prevent deformation.
  • Powerful storage function, can be directly connected to the printer for A4 format data and graphics printing
  • With automatic start function, calibration, and system positioning function.
  • Can export data to U disk.
 
UV VIS Spectrophotometer Specifications:
Model SP-DUV8000 SP-DUV8000I
Wavelength Range 190-1100nm
Spectral Bandwidth 1.8 nm 0.5, 1.0 2.0, 4.0nm
Wavelength Accuracy ±0.1nm (D2 656.1nm), ±0.3 nm full range
Stray Light 0.03% T @ 220 nm, 360 nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.2T(0-1009%T)
±0.002Abs(0-0.5Abs)
±0.004Abs(0.5-1.0Abs)
Photometric Repeatability ≤0.05%6T(0-100%6T)
0.001Abs(0-0.5Abs)
0.002Abs(0.5-1.0Abs)
Stability ±0.0004A/h@500nm
Photometric Range 0-200%T, -0.3-3.0A, 0-9999C
Baseline Flatness ±0.001A
Noise ±0.0004A
Display 800x480 touch screen
Data Output Port USB
Print Port USB Port
Light Source Tungsten Lamp & Deuterium Lamp
Power Requirements AC220V/50Hz or 110v/60Hz
Detector Silicon Photodiode
Size(W×D×H)(mm) 630x430x210
Shipping Size(W×D×H)(mm) 850x650x450
N.W./G.W. (kg) 28/38
Twenty Five (25) Test Strip per Packskyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare