The UV-Visible Spectrophotometer measures the absorption of light in the ultraviolet (UV) and visible parts of the spectrum (typically 200-800 nm). It’s used to determine the concentration of substances in a sample by analyzing the light absorbed at various wavelengths. This makes it a powerful tool in research, chemistry, biology, and materials science.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-66
Brands:: Scitek

Description

UV VIS Spectrophotometer Features:
  • Dual-beam system, dual detectors, the use of high-performance imported grating, lower stray light, more reliable, stable, analysis and more accurate
  • Equipped with 10-inch touch screen, built-in 32G memory, support for Bluetooth connection
  • Built-in mainframe can enter the calibration curve
  • Adopts the suspension design of the optical system, 16mm thick aluminum non-deformation base to prevent deformation.
  • Powerful storage function, can be directly connected to the printer for A4 format data and graphics printing
  • With automatic start function, calibration, and system positioning function.
  • Can export data to U disk.

 

UV VIS Spectrophotometer Specifications:
Model SP-DUV8000 SP-DUV8000I
Wavelength Range 190-1100nm
Spectral Bandwidth 1.8 nm 0.5, 1.0 2.0, 4.0nm
Wavelength Accuracy ±0.1nm (D2 656.1nm), ±0.3 nm full range
Stray Light 0.03% T @ 220 nm, 360 nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.2T(0-1009%T)
±0.002Abs(0-0.5Abs)
±0.004Abs(0.5-1.0Abs)
Photometric Repeatability ≤0.05%6T(0-100%6T)
0.001Abs(0-0.5Abs)
0.002Abs(0.5-1.0Abs)
Stability ±0.0004A/h@500nm
Photometric Range 0-200%T, -0.3-3.0A, 0-9999C
Baseline Flatness ±0.001A
Noise ±0.0004A
Display 800×480 touch screen
Data Output Port USB
Print Port USB Port
Light Source Tungsten Lamp & Deuterium Lamp
Power Requirements AC220V/50Hz or 110v/60Hz
Detector Silicon Photodiode
Size(W×D×H)(mm) 630x430x210
Shipping Size(W×D×H)(mm) 850x650x450
N.W./G.W. (kg) 28/38

Reviews

There are no reviews yet.

Be the first to review “UV Visible Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsUV Visible Spectrophotometer removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge removeEppendorf Pipette Tip 20ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameUV Visible Spectrophotometer removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge removeEppendorf Pipette Tip 20ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageAvalun 48 INR MicrocuvetteEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560130127-66SF1033560084-74SF1033560084-114SF1033560084-136SF1033560060-1SF1033560060-2
Rating
Price

$0.00

$0.00

$72.50

$0.00

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Model : SP-DUV8000; SP-DUV8000I The UV-Visible Spectrophotometer measures the absorption of light in the ultraviolet (UV) and visible parts of the spectrum (typically 200-800 nm). It's used to determine the concentration of substances in a sample by analyzing the light absorbed at various wavelengths. This makes it a powerful tool in research, chemistry, biology, and materials science.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
UV VIS Spectrophotometer Features:
  • Dual-beam system, dual detectors, the use of high-performance imported grating, lower stray light, more reliable, stable, analysis and more accurate
  • Equipped with 10-inch touch screen, built-in 32G memory, support for Bluetooth connection
  • Built-in mainframe can enter the calibration curve
  • Adopts the suspension design of the optical system, 16mm thick aluminum non-deformation base to prevent deformation.
  • Powerful storage function, can be directly connected to the printer for A4 format data and graphics printing
  • With automatic start function, calibration, and system positioning function.
  • Can export data to U disk.
 
UV VIS Spectrophotometer Specifications:
Model SP-DUV8000 SP-DUV8000I
Wavelength Range 190-1100nm
Spectral Bandwidth 1.8 nm 0.5, 1.0 2.0, 4.0nm
Wavelength Accuracy ±0.1nm (D2 656.1nm), ±0.3 nm full range
Stray Light 0.03% T @ 220 nm, 360 nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.2T(0-1009%T)
±0.002Abs(0-0.5Abs)
±0.004Abs(0.5-1.0Abs)
Photometric Repeatability ≤0.05%6T(0-100%6T)
0.001Abs(0-0.5Abs)
0.002Abs(0.5-1.0Abs)
Stability ±0.0004A/h@500nm
Photometric Range 0-200%T, -0.3-3.0A, 0-9999C
Baseline Flatness ±0.001A
Noise ±0.0004A
Display 800x480 touch screen
Data Output Port USB
Print Port USB Port
Light Source Tungsten Lamp & Deuterium Lamp
Power Requirements AC220V/50Hz or 110v/60Hz
Detector Silicon Photodiode
Size(W×D×H)(mm) 630x430x210
Shipping Size(W×D×H)(mm) 850x650x450
N.W./G.W. (kg) 28/38
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A