| Description | Shipped From Abroad
This vertical shaking incubator has a wide and important role in molecular science food, environmental protection and other research applications. Now the best vertical single door shaking incubator for sale at cost price.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | Vertical Single Door Shaking Incubator Features:
- LCD display with bright illumination
- Automatic defrost function
- High precision speed and temperature control
- Memorized and protected operating parameters
- Function of encrypted and locked operating parameters
- Continuously running or timing
- Automatic analyzing, listing table, charting and printing on downloaded dates.
- Unique slow-start design, unique drive system and advantaged air duct design
- High quality servo motor
- Multi-steps rotate speed, temperature and time control systems
- Slow accelerate and decelerate design
Product Data
- Display : LCD display
- Controller : PID
- Circulation Mode : Forced convection
- Shaking Mode : Convolution
- Capacity(L) : 160L
- Size(W×D×H)(mm) : 700×580×1280
Vertical Single Door Shaking Incubator Specifications:
| Model |
ICB-160VS |
ICB-160VSI |
| Display |
LCD display |
| Controller |
PID |
| Circulation Mode |
Forced convection |
| Shaking Mode |
Convolution |
| Drive Mode |
Unidimensional drive |
| Capacity(L) |
160L |
| Temperature Range(℃) |
RT+5~65℃ |
4~65℃ |
| Temperature Accuracy(℃) |
±0.1℃ |
| Temperature Uniformity(℃) |
±0.5℃(at 37℃) |
| Cyclotron Frequency Range(rpm/min) |
20-350(r/min)(To do static culture) |
| Cyclotron Frequency Sensitivity (rpm) |
±1 |
| Orbit Range(mm) |
Φ26 |
| Refrigerant |
/ |
Environmentally friendly refrigerant |
| Timing Range(h/min) |
0-9999h/min (Any time,continuous duty) |
| Standard Capacity |
Clamp flask: 250ml×24 |
| Max. Capacity |
Clamp flask: 100ml×60 or 250ml×38 or 500ml×22 or 1000ml×16 |
|
| Auxiliary Functions |
Ultra-low speed start, Adjustable start speed, Overspeed auto-prtection, Watch dog timer, Parameters Storage, Encryption parameters, Electricity incoming recovery, Refrigeration unit overload protection, Sound and light alarm when upper and lower overtemperature, Function of lighting and UV disinfection, Automatically stop when opening the door (optional) |
| External and Internal Material |
Stainless steel |
| Number of Platform |
Two |
| Power Supply |
AC220V±10%, 50/60Hz; 110V, 60Hz |
| Consumption |
600W |
850W |
| Size(W×D×H)(mm) |
700×580×1280 |
| Shipping Size(W×D×H)(mm) |
850x740x1530 |
| G.W. (kg) |
230 |
|
FDA 510K & CLIA Waived
99% Accurate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 14 substances
Adulterants available
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
| Principle of Measure: |
Photometrical |
| Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
| Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
| Tube Requirements: |
13 x 75 mm, pierceable capped tube |
| Quality Control: |
Barcoded Seditrol® QC |
| Barcode Reader: |
Internal |
| Printer: |
Internal |
| Interface Specifications: |
serial RS232 port for LIS connection |
| Weight: |
14 kg |
| Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
| Voltage: |
100-240VAC |
| Frequency Range: |
50-60 Hz |
| Power: |
160W |
Click Here To Download Catalogue |
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
|
Reviews
There are no reviews yet.