Visible Spectrophotometer, Bandwidth 2/4nm

$0.00

Shipped From Abroad

Visible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-53
Brands:: Scitek

Description

Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer’s solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.

 

Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128×64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer, Bandwidth 2/4nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer, Bandwidth 2/4nm removeMotic BA210 Series Biomedical Microscope removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeErma B-111 Bilirubin Meter removeDiscover 14 Panel Cup with Adulterants Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NameVisible Spectrophotometer, Bandwidth 2/4nm removeMotic BA210 Series Biomedical Microscope removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeErma B-111 Bilirubin Meter removeDiscover 14 Panel Cup with Adulterants Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageDrug Test CupDrug Test Cup
SKUSF1033560130127-53SF1033560084-78SF1033560084-30SF1033560084-6SF1033560084-28SF1033560084-23
Rating
Price

$0.00

$0.00

$9.50

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadVisible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer's solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.
 
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128x64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  Twenty Five (25) Test Strip per PackThe advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare