Visible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-53
Brands:: Scitek

Description

Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer’s solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.

 

Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128×64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer, Bandwidth 2/4nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer, Bandwidth 2/4nm removeiSED Fully Automated ESR Analyzer removeHawksley 1400 Haematocrit Centrifuge removeSugentech Inclix (POCT) Immunoassay Analyzer removeAvalun LabPad Device removeAlcohol Pad Per Pack remove
NameVisible Spectrophotometer, Bandwidth 2/4nm removeiSED Fully Automated ESR Analyzer removeHawksley 1400 Haematocrit Centrifuge removeSugentech Inclix (POCT) Immunoassay Analyzer removeAvalun LabPad Device removeAlcohol Pad Per Pack remove
ImageAvalun Labpad machine
SKUSF1033560130127-53SF1033560084-129SF1033560084-118SF1033560084-89SF1033560084-65SF1033560084-64
Rating
Price

$0.00

$0.00

$690.00

$0.00

$0.00

$4.25

Stock
Availability
Add to cart

DescriptionShipped From AbroadVisible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer's solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.
 
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128x64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare