New

Visible Spectrophotometer Spectrum Bandwidth 5nm

Ask for Price$0.00

Shipped From Abroad

The visible spectrophotometer measures the light absorbed by a sample within the visible spectrum (400-800 nm). It’s crucial in determining the concentration of substances, by passing light through a sample and measuring the absorption at various wavelengths.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Scitek

Description

Visible Spectrophotometer Features:
  1. Sample chamber for 5-100mm cuvettes
  2. Precise automatic T/A conversion
  3. RS232 interface
  4. Direct concentration reading and concentration factor setting
  5. Automatic zero and full scale adjustment
  6. Standard software (SP-VG721)
  7. Optional dedicated printer (SP-VGI721)

 

Common Features
  1. High quality silicon photodiode detector and 1200 lines/mm diffraction grating ensure high quality accuracy and precision.
  2. Automatic 0%A and 100%T.
  3. Backlit LED display for easy reading.
  4. Easily switch between transmittance, absorbance and concentration modes.
  5. Users can easily change halogen or deuterium lamps on their own.
  6. Direct concentration readout and concentration factor setting capability.
  7. Cuvettes from 5 – 100mm optical lengths with optional holders.

 

Visible Spectrophotometer Specifications:
Model SP-VG722 SP-VGI721 SP-VG721
Photometry Single Beam
Monochromator Type Czerny-Turner
Detector Silicon Photocell
Wavelength Setting Manual Turn Knob
Wavelength Range 325-1000nm 340-1000nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ≤1nm
Spectrum Bandwidth 5nm
Stray Light ≤0.5%T (at 360nm NaNo2)
Photometric Range 0-100.0%T
0-1.999A
0-1999C
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Noise 100% (T) noise ≤0.3% (T), 0% (T) noise ≤0.2% (T)
Drifting ±0.5 %T/3min
Cuvette Holder Size 50mm 100mm 50mm
Power AC220V±22V; 50Hz±1Hz, 50W
Size(W×D×H)(mm) 400x300x200
Shipping Size(W×D×H)(mm) 560x500x300
N.W./G.W. (kg) 13/15

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer Spectrum Bandwidth 5nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

Visible Spectrophotometer Spectrum Bandwidth 5nm removeEppendorf Pipette Tip 200ul Per Pack removeAutomatic Pipette removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer remove
NameVisible Spectrophotometer Spectrum Bandwidth 5nm removeEppendorf Pipette Tip 200ul Per Pack removeAutomatic Pipette removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer remove
ImageEppendorf Pipette Tip 200ul Per PackDrug Test CupAvalun Labpad machine
SKUSF1033560084-137SF1033560084-130SF1033560084-28SF1033560084-65SF1033560084-129
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The visible spectrophotometer measures the light absorbed by a sample within the visible spectrum (400-800 nm). It’s crucial in determining the concentration of substances, by passing light through a sample and measuring the absorption at various wavelengths.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Visible Spectrophotometer Features:
  1. Sample chamber for 5-100mm cuvettes
  2. Precise automatic T/A conversion
  3. RS232 interface
  4. Direct concentration reading and concentration factor setting
  5. Automatic zero and full scale adjustment
  6. Standard software (SP-VG721)
  7. Optional dedicated printer (SP-VGI721)
 
Common Features
  1. High quality silicon photodiode detector and 1200 lines/mm diffraction grating ensure high quality accuracy and precision.
  2. Automatic 0%A and 100%T.
  3. Backlit LED display for easy reading.
  4. Easily switch between transmittance, absorbance and concentration modes.
  5. Users can easily change halogen or deuterium lamps on their own.
  6. Direct concentration readout and concentration factor setting capability.
  7. Cuvettes from 5 - 100mm optical lengths with optional holders.
 
Visible Spectrophotometer Specifications:
Model SP-VG722 SP-VGI721 SP-VG721
Photometry Single Beam
Monochromator Type Czerny-Turner
Detector Silicon Photocell
Wavelength Setting Manual Turn Knob
Wavelength Range 325-1000nm 340-1000nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ≤1nm
Spectrum Bandwidth 5nm
Stray Light ≤0.5%T (at 360nm NaNo2)
Photometric Range 0-100.0%T
0-1.999A
0-1999C
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Noise 100% (T) noise ≤0.3% (T), 0% (T) noise ≤0.2% (T)
Drifting ±0.5 %T/3min
Cuvette Holder Size 50mm 100mm 50mm
Power AC220V±22V; 50Hz±1Hz, 50W
Size(W×D×H)(mm) 400x300x200
Shipping Size(W×D×H)(mm) 560x500x300
N.W./G.W. (kg) 13/15
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare