Description Shipped From Abroad
Features:
50KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Features:
50KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Specifications:
MODEL
RM Plus 300K
RM Plus 350K
RM Plus 400K
RM Plus 500K
Phase
3 Phase in / 3 Phase out
Cabinet Capacity*
300 KW
350 KW
400KW
500KW
Battery Type
Extemal Battery
One Power Module Capacity
50KVA/50KW
Max. Power Module No.
6
7
8
10
INPUT
Nominal Voltage
3×380/400/415 VAC (3Ph+N)
Voltage Range
’-20%~+15%
Nominal Frequency
50/60Hz(Auto Sensing)
Frequency Range
40Hz~70Hz
Power Factor
>0.99 @100% Load, >0.98@50% Load
Harmonic Distortion (THDi)
<4% @ 100% load
OUTPUT
Nominal Voltage
3×380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady State)
≤ ±1% Typical (balanced load); ~≤ ±2% Typical (unbalanced load)
Nominal Frequency
50/60Hz
Frequency Range(Synchronized)
46Hz~54Hz or 56Hz~64Hz
Overload Capability
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion
≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency
95.50%
BATTERY / CHARGER
Nominal Voltage
‘+/- 192V~+/- 240V (Selectable)
Maximum Voltage
’+/- 240V (12V×40PCS)
Minimum Voltage
‘+/- 192V(12V×32PCS)
Floating Charge Voltage
2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage
2.35V/Cell
Temperature Compensation
Yes
Maximum Charging Current
(Per Power Module)
12A (Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm
1065x600x2000
1065x600x2000
1065x1000x2000
1065x1000x2000
Net Weight (Kg)
545
654
932
1020
Power Module (PM-50) Net Weight
44KGS
ENVIRONMENT
Operating Temperature
0~40℃
Relative Humidity
0~95% non-condensing
Altitude*
<1000m for Nominal power
IP Protection
IP 20
MANAGEMENT
Smart RS-232/USB
Supports Windows⑧ Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
STANDARDS
Safety
IEC/EN 62040-1
EMC
IEC/EN 62040-2 Category C3
Features:
Capacity: 1200W 1008Wh /315000mAh
Input AC Output Power:Rated Power 1200W Peak Power 2400W
Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
Input Car Charging:DC12V~24V/10A 240W Max
Input Solar Charging:DC12V~60V/10A 400W Max
Output Voltage:230VAC±10%/110VAC±10%
Output Frequency: 50Hz±5%/60Hz±5%
USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
Output Waveform:Pure Sine Wave
LED:3 Levels(H/M/L)+SOS
UPS Function:Support(≤10mS)
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Specifications
MODEL
DX100KVA
DX120KVA
DX125KVA
DX150KVA
DX160KVA
190KVA
200KVA
Rated Power
80KW
96KW
100KW
120KW
128KW
150KW
160KW
Peak Power(20ms)
240KVA
288KVA
300KVA
360KVA
384KVA
450KVA
480KVA
Start Motor
40HP
50HP
50HP
60HP
60HP
80HP
80HP
Battery Voltage
384VDC
Size(L*W*Hmm)
875*720*1380
1123*900*1605
Packing Size(L*W*Hmm)
980*825*1560
1185*960*1750
N.W.(kg)
512
592
612
612
642
705
755
G.W.(kg)(Wooden Packing)
552
632
652
652
692
755
805
INPUT
DC Input Voltage Range
10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range
380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current
0-45A(Depending on the model)
AC charging method
Three-stage (constant current, constant voltage, floating charge)
Phase
3 PHASE
OUTPUT
Efficiency(Battery Mode)
≥85%
Output Voltage(Battery Mode)
380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode)
50/60Hz ±1%
Output Wave(Battery Mode)
Pure Sine Wave
Output waveform distortion
Linear load≤3%
Efficiency(AC Mode)
>99%
Output Voltage(AC Mode)
Conforming to AC input
Output Frequency(AC Mode)
Conforming to AC input
No load loss(Battery Mode)
≤1% rated power
No load loss(AC Mode)
≤2%rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Phase
3 PHASE
BATTERY
VRLA Battery
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection
Battery undervoltage alarm
11V(Single battery voltage)
Battery undervoltage protection
10.5V(Single battery voltage)
Battery overvoltage alarm
15V(Single battery voltage)
Battery overvoltage protection
17V(Single battery voltage)
Battery overvoltage recovery voltage
14.5V(Single battery voltage)
Overload power protection
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection
>90°C(Shut down output)
Alarm
A
Normal working condition, buzzer has no alarm sound
B
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal
Inside Solar controller
Charging Mode
MPPT or PWM
(Optional)
Charging current
PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range
PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc)
PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss
≤3W
Maximum conversion efficiency
>95%
Working Mode
Battery First/AC First/Saving Energy Mode
Transfer Time
≤4ms
Display
LCD
Thermal method
Forced Air Cooling
Communication(Optional)
RS485/APP(WIFI monitoring or GPRS monitoring)
Environment
Operating temperature
-10℃~40℃
Storage temperature
-15℃~60℃
Noise
2000m(More than derating)
Elevation
≤65dB
Humidity
0%~95% ,No condensation
Features:
One of the most popular rechargeable battery generators in the market. It comes with AC outlets,DC car port,three Quick Charge USB ports,one Type-C port and built-in fast charging wireless charger.
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
ADVANCE 300W
ADVANCE 500W
ADVANCE 1000W
ADVANCE 1500W
Power
300W Rated Power
600W Peak Power
500W Rated Power
1000W Peak Power
1000W Rated Power
2000W Peak Power
1500W Rated Power
3000W Peak Power
Input
DC, 7909,12-28V
DC, 7909,12-28V
DC, 7909,12-28V
DC, 8020,12-60V
PV(Anderson) 12-60V
Battery Type
18650 Lithium-ion Battery 2.6Ah
18650 Lithium-ion Battery 3.0Ah
18650 Lithium-ion Battery 3.0Ah
18650 Lithium-ion Battery 2.6Ah
Capacity
silk-screen
231Wh(22.2V 10.4Ah)
400Wh(22.2V 18Ah)
933Wh(22.2V 42Ah)
1328Wh (22.2V 59.8Ah)
single cell
Volts(V)
3.7V
3.7V
3.7V
3.7V
Capacity(Ah)
2.6Ah
3.0Ah
3.0Ah
2.6Ah
Cascade No.
6
6
6
6
Parallel No.
4
6
14
23
Input
Watts
Wall Charger
48W
100W
150W
240W
Solar Panel
80W
100W
120W
600W
Car Port
55W
60W
60W
60W
Recharge
Time
Wall Charger
4.8h
4.0h
6.2h
5.5h
Solar Panel
2.9h
4.0h
7.8h
2.2h
Car Port
4.2h
6.7h
15.5h
22.1h
AC Outlet
Germany
1x , 230V, 50Hz((with cover)
1x , 230V, 50Hz((with cover)
2x ,230V , 50Hz(with cover)
3x ,230V , 50Hz
DC Output
1XCigarette lighter port ,
12V 10A
1XCigarette lighter port ,
12V 10A
1XCigarette lighter port ,
12V 10A
2x 5525 ,1XCigarette lighter port,
Parallel output 12V 10A
1×7406 24V 5A
USB Output
2*USB-A QC 3.0 18W each,36W Max
1*USB-C PD3.0 60W Max
3*USB-A QC 3.0 18W each,54W Max
1*USB-C PD3.0 60W Max
3*USB-A QC 3.0 18W each,54W Max
1*USB-C PD3.0 60W Max
2*USB-A QC 3.0 18W each,36W Max
2*USB-C PD3.0 120W Max
Wireless Charger
/
1x, 10W
1x, 10W
1x, 10W
LED light
/
1x 1W
1x 1W
1x 1W
Flashlight
1x 1W
1x 1W
1x 1W
/
LCD Display
Yes
Yes
Yes
Yes
Charging Temp
0~40℃
0~40℃
0~40℃
0~40℃
Operating Temp
﹣ 10~40℃
﹣ 10~40℃
﹣ 10~40℃
﹣ 10~40℃
Accesssories
48W Adapter x83cm,
AC Cable x48cm,
Car charger cable x131cm,
Instruction manual
100W Adapter x81cm,
AC Cable x48cm,
Car charger cable x131cm,
Instruction manual
150W Adapter x81cm,
AC Cable x121cm,
Car charger cable x131cm,
Instruction manual.
240W Adapter x150cm,
AC Cable x121cm,
Car charger cable x131cm,
Instruction manual.
Products Size(mm)
192*142*148mm
230*168*178mm
290*201*200mm
350*265*240mm
Package
N.W
2.76kg
4.42kg
8.55kg
14.1kg
Box Size
238*218*190mm
276*241*227mm
371*254*262mm
455*355*345mm
G.W
3.7kg
5.14kg
9.74kg
15.96kg
Carton Size
504*460*233mm
525*301*267mm
555*406*316mm
471*377*375mm
Carton/pcs
4pcs
2pcs
2pc
1pc
G.W
16.06kg
11.8kg
20.37kg
17.9kg
Loading Quantity
(20GP/40GP/40HQ)
1740 / 3880 / 4800
1160 /2580 / 3200
690 1530 /1900
368/ 818 /1015
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT6K
VT6KL
VT10K
VT10KL
31VT10KL
31VT15KL
31VT20KL
Capacity
6KVA/5400W
10KVA/9000W
15KVA/13.5KW
20KVA/18KW
Input
Nominal Voltage
220/230/240Vac
380/400/415Vac
Voltage Range
120-275VAC(1P2W+G)
207-475VAC(3P4W+G)
Current
31A (max)
50A(max)
50A (max)
75A(max)
100A(max)
Frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Power Factor
≥0.99·
Output
Voltage
220/230/240±2%Vac (1P2W+G)
Frequency
50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode)
Current
27.3A
45A
68A
91A
Power Factor
0.9
Waveform
Pure Sine Wave
Waveform Distortion
Line load <2%
Line load <3%
Back-up Time
Full Load
≥7′
Depends on external batteries bank’s Capacity
≥5′
Depends on external batteries bank’s Capacity
Half Load
≥20
≥13′
Battery Nominal Voltage
192/240Vdc
Transfer Time
0ms
Overload Capacity
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass
Communication
SNMP,RS-232,USB+lntelligent Slot
Operating Environment
Temperature
0°C~40°C
Humidity
15%~90%
Dimension
Width (mm)
260
260
260
260
260
Depth (mm)
560
533
560
533
560
Height (mm)
717
501
717
501
717
Net Weight(Kg)
55
12.2
62
21
23
32
33
Features:
Rated Power: 1000W
Rated Capacity: 932.4wh
Standard Capacity: 3.7V/252000mah
Overload Protecion: 1050+40W
AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
Output Wave: Pure sine wave
USB Output: QC 18W*2
Type-c Output: PD 60W*2
Cigarret Lighter Output: 14V/8A
DC5525 Output: 14V/8A
Wireless Charging: 15W
Charging Input: 12-26 V/150W Max
WorkingTemperature: -10-40 °C
Weight(Net Weight): 8. 2kg
Weight(With Accessories): 10.2kg
Dimension: 345*227*203mm
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Reviews
There are no reviews yet.