Single Phase Low Frequency Power Inverter VK Series 300W-1200W

$0.00

Shipped From Abroad

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-29
Brands:: Reeco Power

Description

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
MODEL VK300W VK500W VK700W VK800W VK1000W VK1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET)
01: AC priority/Citypower priority:
When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power charges power to battery. When city power failed, will use battery power to take the appliances.02: energy saving mode
load power ≤10% off the machine, ≥11% -100% turn on 

03: Battery priority
When it have has battery power, battery supply power to the appliances. When battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use use battery power

External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5 6 6.5 7.5 8.5 9.5
Gross Weight(KG) 12 14 15 17 19 21

Reviews

There are no reviews yet.

Be the first to review “Single Phase Low Frequency Power Inverter VK Series 300W-1200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

Single Phase Low Frequency Power Inverter VK Series 300W-1200W removeHigh Frequency Rack Mount UPS 33RM Series remove3 Phase Low Frequency Online UPS LD31 Series removePortable Power Station PX Series 1000W removeHigh Frequency Modular UPS VM Series removePortable Power Station PX Series 500W remove
NameSingle Phase Low Frequency Power Inverter VK Series 300W-1200W removeHigh Frequency Rack Mount UPS 33RM Series remove3 Phase Low Frequency Online UPS LD31 Series removePortable Power Station PX Series 1000W removeHigh Frequency Modular UPS VM Series removePortable Power Station PX Series 500W remove
Image
SKUSF1033560130139-29SF1033560130139-12SF1033560130139-2SF1033560130139-23SF1033560130139-11SF1033560130139-24
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • Have UPS function and AC charger function
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
MODEL VK300W VK500W VK700W VK800W VK1000W VK1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET) 01: AC priority/Citypower priority: When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power charges power to battery. When city power failed, will use battery power to take the appliances.02: energy saving mode load power ≤10% off the machine, ≥11% -100% turn on  03: Battery priority When it have has battery power, battery supply power to the appliances. When battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use use battery power
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5 6 6.5 7.5 8.5 9.5
Gross Weight(KG) 12 14 15 17 19 21
Features:
  • True double-conversion
  • LCD screen auto-rotation with Rack position ( only for 10K-20K models)
  • DSP technology guarantees high performance
  • Output power factor 1
  • Support 1/1;3/1;3/3 Phase Adjustable
  • Active power factor correction in all phases
  • 50HZ / 60HZ frequency converter mode
  • ECO mode operation for energy saving ( ECO)
  • Emergency power off function ( EPO)
  • Generator compatible
  • Supports dual AC inputs
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers for long-run model
  • Supporting Parallel sharing of battery packs
  • Optional isolation transformer offers full isolation and complete common mode noise rejection
  • Support with SNMP,USB, RS232 communication
 
Technical Specifications
MODEL 33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
CAPACITY 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
PHASE 3 Phase input / 3 Phase output
PARALLEL CAPABILITY 4 Max
INPUT
Nominal Voltage 3×380 VAC (3Ph+N)
Voltage Range 190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load
Frequency Range 46-54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤1 % THD (Linear Load), ≤3% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Battery Type Depending on the applications
Numbers 20 pcs 32-40 pcs (Adjustable)
Charging Current (max.) 1A~ 12A (Adjustable) 1A~ 16A (Adjustable) 1A 〜18A (Adjustable)
Charging Voltage ±13.65 VDCx N (N=10) ±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm) 680*438*133 [3U] 797*438*176 [4U]
Net Weight (kgs) 27 30 40 45
ENVIRONMENT
Operation Temperture 0-40°C
Operation Humidity 0-95% and non-condersing
Noise Level Less than 62dB @ 1 Meter Less than 65dB @ 1 Meter Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA    80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW    64 KW    80 KW
INPUT
Rated voltage 380/400/415 VAC  Three-phase
Voltage range ±20%
Frequency range 45-65Hz
Power factor >0.92 with harmonic filter
Current harmonic distortion <5% with harmonic filter
Soft Start 0 -100% in 10″
BYPASS INPUT
Rated voltage 230VAC   Single Phase
Permitted voltage range ±15%  (selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%    (selectable from ±1% to ±5% from front panel)
Standard features Back Feed portection; split bypass line
BATTERY
Type VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum recharge current(A) 0.2 X C10
AC ripple voltage <1%
INVERTER OUTPUT
Rated power(kVA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Active power(kW)  8KW 12 KW 16 KW 24 KW 32 KW 48 KW     64 KW 80 KW
Number of phases 1
Rated voltage(V) 230VAC  Single Phase
Regulation of the output voltage 220 ~ 244VAC  phase/neutral (from control panel)
Crest factor(Ipeak/Irms) 3:1
Static stability ±1%
Dynamic stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10’/1′
Frequency stability ±0.05% on mains failure
System 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + Romote Contacts
Operation temperature 0℃ to  ~ 40℃
Relative humidity <95% non condensing
Colour Light grey ( RAL 7035)
Noise 54dBA at 1m 60dBA at 1m   65dBA at 1m
Protection degree IP20
Efficiency Smart Mode Up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
Weight(KG)N.W 176 220 205 213 295 440 520 770
Dimensions:(WxDxH)mm 555*730*1210 800*730*1400 1115*730*1400
Internal batteries optional optional optional No      No No No No
Features:
  • Rated Power: 1000W
  • Rated Capacity: 932.4wh
  • Standard Capacity: 3.7V/252000mah
  • Overload Protecion: 1050+40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/150W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 8. 2kg
  • Weight(With Accessories): 10.2kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
  • Rated Power: 500W
  • Rated Capacity: 519 . 48wh
  • Standard Capacity: 3.7V/140400mah
  • Overload Protecion: 550W + 40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/100W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 6.8kg
  • Weight(With Accessories): 8.5kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare