Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W

$0.00

Shipped From Abroad

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-28
Brands:: Reeco Power

Description

Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller

 

Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

 

Technical Specifications
MODEL VKS300W VKS500W VKS700W VKS800W VS1000W VKS1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Solar Controller 10A/20A/30A
Solar Input 120W 240W 360W 480W 720W
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range AVR output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET)
01: AC priority/Citypower priority:
When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power and sun power will charges 2 kinds power to battery. When city power failed,Sun power will charge the battery and  use battery power(Solar power) to take the appliances.02: energy saving mode
load power ≤10% off the machine, ≥11% -100% turn on03: Solar power priority/ Battery priority
When it have sun power,sun power charges the battery and supply power to the appliances.When it does not have sun power or battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use battery power and sun power.
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5.5 6.5 7 8 9.5 10
Gross Weight(KG) 13 15 16 18 20 22

Reviews

There are no reviews yet.

Be the first to review “Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

Single Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W remove3 Phase Low Frequency Online UPS LD33 Series removePortable Power Generator PS Series 600W removePortable Power Station PX Series 1000W removeHigh Frequency Modular UPS VM Series remove3 Phase Low Frequency Solar Inverter DX Series remove
NameSingle Phase Low Frequency Hybrid Solar Inverter VKS Series 300W-1200W remove3 Phase Low Frequency Online UPS LD33 Series removePortable Power Generator PS Series 600W removePortable Power Station PX Series 1000W removeHigh Frequency Modular UPS VM Series remove3 Phase Low Frequency Solar Inverter DX Series remove
Image
SKUSF1033560130139-28SF1033560130139-3SF1033560130139-20SF1033560130139-23SF1033560130139-11SF1033560130139-5
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Pure sine wave output
  • AC Charging current 15A
  • High-low voltage protection
  • Against overload, short-circuit Protection
  • Over voltage,battery reverse connection(optional)
  • Under-voltage and over-temperature protection
  • Selectable battery priority or utility priority
  • UPS function and AC charger function
  • Built in 10A/20A/30A solar charge PWM controller
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
MODEL VKS300W VKS500W VKS700W VKS800W VS1000W VKS1200W
Rated Power 300W 500W 700W 800W 1000W 1200W
Peak Power 600W 1000W 1400W 1600W 2000W 2400W
AC input voltage range 73V-135VAC(110VAC/120VAC) 145V-275VAC(220VAC /230VAC )
Input frequency range 45-65HZ
Battery voltage 12VDC /24VDC
DC voltage 12VDC:10.5 -15VDC/24VDC:21-30VDC
Solar Controller 10A/20A/30A
Solar Input 120W 240W 360W 480W 720W
Battery undervoltage alarm 10.5VDC /21VDC
Battery undervoltage protection 10VDC /20VDC
Battery overvoltage protection 17V±0.5V /34V±0.5V
Voltage overvoltage alarm 15V-16VDC/30V-32VDC
Overload protection Rated power of 110% or more
Temperature protection ≥85 °C alarm, ≥90 °C off the machine
Inverter output voltage 110VAC/120VAC/ 220VAC/230VAC ±2%
Inverter output frequency 50/60HZ±10%
Inverter output waveform pure sine wave
AC output voltage range AVR output 110VAC/120VAC/ 220VAC/230VAC ±10%
Output frequency range Automatic tracking
Conversion time <5ms
Cooling method Intelligent fan control, ≤42 °C fan slow working , ≥45 °C fan high working .
AC Charging current 15A
Working mode selection Free to choose(SET) 01: AC priority/Citypower priority: When city power is available, the inverter will work AC output, city power will supply power to appliances.The city power and sun power will charges 2 kinds power to battery. When city power failed,Sun power will charge the battery and  use battery power(Solar power) to take the appliances.02: energy saving mode load power ≤10% off the machine, ≥11% -100% turn on03: Solar power priority/ Battery priority When it have sun power,sun power charges the battery and supply power to the appliances.When it does not have sun power or battery voltage ≤10.5V, inverter will automatic use city power to take the appliances, When battery voltage reach 13V inverter will use battery power and sun power.
External Size(mm) DxWxH 300*290*150mm
Packing Size(mm) DxWxH 350*350*405(2pcs)
Net Weight(KG) 5.5 6.5 7 8 9.5 10
Gross Weight(KG) 13 15 16 18 20 22
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
  • Capacity: 600W 512Wh /160000mAh
  • Input AC Output Power:Rated Power 600W Peak Power 1200W
  • Input AC Charging:AC100~120V/AC200~240V Built-in 200W
  • Input Car Charging:DC12V~24V/7A Max 120W Max
  • Input Solar Charging:DC12V~24V/120WMax
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC24W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Rated Power: 1000W
  • Rated Capacity: 932.4wh
  • Standard Capacity: 3.7V/252000mah
  • Overload Protecion: 1050+40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/150W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 8. 2kg
  • Weight(With Accessories): 10.2kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A